Optimized 3D brachial plexus MR neurography using deep learning reconstruction

被引:2
|
作者
Sneag, D. B. [1 ,2 ]
Queler, S. C. [1 ,3 ]
Campbell, G. [1 ]
Colucci, P. G. [1 ]
Lin, J. [1 ]
Lin, Y. [1 ]
Wen, Y. [4 ]
Li, Q. [1 ]
Tan, E. T. [1 ]
机构
[1] Hosp Special Surg, Dept Radiol & Imaging, 535 E 70th St, New York, NY 10021 USA
[2] Weill Cornell Med Coll, New York, NY 10021 USA
[3] SUNY Downstate Hlth Sci Univ, Coll Med, Brooklyn, NY USA
[4] GE Healthcare, Waukesha, WI USA
关键词
Magnetic Resonance Neurography; Brachial Plexus; Peripheral Nerves; Three-Dimensional Imaging; Artificial Intelligence; Deep Learning;
D O I
10.1007/s00256-023-04484-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate whether 'fast,' unilateral, brachial plexus, 3D magnetic resonance neurography (MRN) acquisitions with deep learning reconstruction (DLR) provide similar image quality to longer, 'standard' scans without DLR.Materials and methods: An IRB-approved prospective cohort of 30 subjects (13F; mean age = 50.3 +/- 17.8y) underwent clinical brachial plexus 3.0 T MRN with 3D oblique-coronal STIR-T(2-)weighted-FSE. 'Standard' and 'fast' scans (time reduction = 23-48%, mean = 33%) were reconstructed without and with DLR. Evaluation of signal-to-noise ratio (SNR) and edge sharpness was performed for 4 image stacks: 'standard non-DLR,' 'standard DLR,' 'fast non-DLR,' and 'fast DLR.' Three raters qualitatively evaluated 'standard non-DLR' and 'fast DLR' for i) bulk motion (4-point scale), ii) nerve conspicuity of proximal and distal suprascapular and axillary nerves (5-point scale), and iii) nerve signal intensity, size, architecture, and presence of a mass (binary). ANOVA or Wilcoxon signed rank test compared differences. Gwet's agreement coefficient (AC(2)) assessed inter-rater agreement.Results: Quantitative SNR and edge sharpness were superior for DLR versus non-DLR (SNR by + 4.57 to + 6.56 [p < 0.001] for 'standard' and + 4.26 to + 4.37 [p < 0.001] for 'fast;' sharpness by + 0.23 to + 0.52/pixel for 'standard' [p < 0.018] and + 0.21 to + 0.25/pixel for 'fast' [p < 0.003]) and similar between 'standard non-DLR' and 'fast DLR' (SNR: p = 0.436-1, sharpness: p = 0.067-1). Qualitatively, 'standard non-DLR' and 'fast DLR' had similar motion artifact, as well as nerve conspicuity, signal intensity, size and morphology, with high inter-rater agreement (AC(2): 'standard' = 0.70-0.98, 'fast DLR' = 0.69-0.97).Conclusion: DLR applied to faster, 3D MRN acquisitions provides similar image quality to standard scans. A faster, DL-enabled protocol may replace currently optimized non-DL protocols.
引用
收藏
页码:779 / 789
页数:11
相关论文
共 50 条
  • [41] Brachial plexus 3D reconstruction from MRI with dissection validation: a baseline study for clinical applications
    Joris Van de Velde
    Stephanie Bogaert
    Pieter Vandemaele
    Wouter Huysse
    Eric Achten
    Joris Leijnse
    Wilfried De Neve
    Tom Van Hoof
    Surgical and Radiologic Anatomy, 2016, 38 : 229 - 236
  • [42] CHOROID PLEXUS SEGMENTATION USING OPTIMIZED 3D U-NET
    Zhao, Li
    Feng, Xue
    Meyer, Craig H.
    Alsop, David C.
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 381 - 384
  • [43] 3D Face Reconstruction in Deep Learning Era: A Survey
    Sahil Sharma
    Vijay Kumar
    Archives of Computational Methods in Engineering, 2022, 29 : 3475 - 3507
  • [44] Improved Lightweight Deep Learning Algorithm in 3D Reconstruction
    Zhang, Tao
    Cao, Yi
    CMC-COMPUTERS MATERIALS & CONTINUA, 2022, 72 (03): : 5315 - 5325
  • [45] Deep learning-based 3D reconstruction: a survey
    Samavati, Taha
    Soryani, Mohsen
    ARTIFICIAL INTELLIGENCE REVIEW, 2023, 56 (09) : 9175 - 9219
  • [46] Medical 3D Reconstruction Based on Deep Learning for Healthcare
    Wang, Jia-Ji
    Chen, Shu-Wen
    Shao, Jia-Qi
    Gu, Xiao-Wei
    Zhu, Hui-Sheng
    COMPANION PROCEEDINGS OF THE 14TH IEEE/ACM INTERNATIONAL CONFERENCE ON UTILITY AND CLOUD COMPUTING (UCC'21 COMPANION), 2021,
  • [47] 3D Face Reconstruction in Deep Learning Era: A Survey
    Sharma, Sahil
    Kumar, Vijay
    ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2022, 29 (05) : 3475 - 3507
  • [48] Incremental SFM 3D Reconstruction Based on Deep Learning
    Liu, Lei
    Wang, Congzheng
    Feng, Chuncheng
    Gong, Wanqi
    Zhang, Lingyi
    Liao, Libin
    Feng, Chang
    ELECTRONICS, 2024, 13 (14)
  • [49] Deep learning-based 3D reconstruction: a survey
    Taha Samavati
    Mohsen Soryani
    Artificial Intelligence Review, 2023, 56 : 9175 - 9219
  • [50] Thoracic outlet syndrome in 3T MR neurography—fibrous bands causing discernible lesions of the lower brachial plexus
    P. Baumer
    H. Kele
    T. Kretschmer
    R. Koenig
    M. Pedro
    M. Bendszus
    M. Pham
    European Radiology, 2014, 24 : 756 - 761