Optimized 3D brachial plexus MR neurography using deep learning reconstruction

被引:2
|
作者
Sneag, D. B. [1 ,2 ]
Queler, S. C. [1 ,3 ]
Campbell, G. [1 ]
Colucci, P. G. [1 ]
Lin, J. [1 ]
Lin, Y. [1 ]
Wen, Y. [4 ]
Li, Q. [1 ]
Tan, E. T. [1 ]
机构
[1] Hosp Special Surg, Dept Radiol & Imaging, 535 E 70th St, New York, NY 10021 USA
[2] Weill Cornell Med Coll, New York, NY 10021 USA
[3] SUNY Downstate Hlth Sci Univ, Coll Med, Brooklyn, NY USA
[4] GE Healthcare, Waukesha, WI USA
关键词
Magnetic Resonance Neurography; Brachial Plexus; Peripheral Nerves; Three-Dimensional Imaging; Artificial Intelligence; Deep Learning;
D O I
10.1007/s00256-023-04484-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate whether 'fast,' unilateral, brachial plexus, 3D magnetic resonance neurography (MRN) acquisitions with deep learning reconstruction (DLR) provide similar image quality to longer, 'standard' scans without DLR.Materials and methods: An IRB-approved prospective cohort of 30 subjects (13F; mean age = 50.3 +/- 17.8y) underwent clinical brachial plexus 3.0 T MRN with 3D oblique-coronal STIR-T(2-)weighted-FSE. 'Standard' and 'fast' scans (time reduction = 23-48%, mean = 33%) were reconstructed without and with DLR. Evaluation of signal-to-noise ratio (SNR) and edge sharpness was performed for 4 image stacks: 'standard non-DLR,' 'standard DLR,' 'fast non-DLR,' and 'fast DLR.' Three raters qualitatively evaluated 'standard non-DLR' and 'fast DLR' for i) bulk motion (4-point scale), ii) nerve conspicuity of proximal and distal suprascapular and axillary nerves (5-point scale), and iii) nerve signal intensity, size, architecture, and presence of a mass (binary). ANOVA or Wilcoxon signed rank test compared differences. Gwet's agreement coefficient (AC(2)) assessed inter-rater agreement.Results: Quantitative SNR and edge sharpness were superior for DLR versus non-DLR (SNR by + 4.57 to + 6.56 [p < 0.001] for 'standard' and + 4.26 to + 4.37 [p < 0.001] for 'fast;' sharpness by + 0.23 to + 0.52/pixel for 'standard' [p < 0.018] and + 0.21 to + 0.25/pixel for 'fast' [p < 0.003]) and similar between 'standard non-DLR' and 'fast DLR' (SNR: p = 0.436-1, sharpness: p = 0.067-1). Qualitatively, 'standard non-DLR' and 'fast DLR' had similar motion artifact, as well as nerve conspicuity, signal intensity, size and morphology, with high inter-rater agreement (AC(2): 'standard' = 0.70-0.98, 'fast DLR' = 0.69-0.97).Conclusion: DLR applied to faster, 3D MRN acquisitions provides similar image quality to standard scans. A faster, DL-enabled protocol may replace currently optimized non-DL protocols.
引用
收藏
页码:779 / 789
页数:11
相关论文
共 50 条
  • [31] Guest Editorial: Deep Learning for 3D Reconstruction
    Lv, Zhihan
    Wang, Xiaokang
    Khan, Sheheryar
    Kumar, Neeraj
    IET IMAGE PROCESSING, 2020, 14 (07) : 1217 - 1218
  • [32] DEEP LEARNING FOR 3D BUILDING RECONSTRUCTION: A REVIEW
    Buyukdemircioglu, Mehmet
    Kocaman, Sultan
    Kada, Martin
    XXIV ISPRS CONGRESS IMAGING TODAY, FORESEEING TOMORROW, COMMISSION II, 2022, 43-B2 : 359 - 366
  • [33] 3D Image Reconstruction Using Virtual Reality and Multimodal Deep Learning
    Chen, Yong
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2024,
  • [34] Automated 3D Fetal Brain Segmentation Using an Optimized Deep Learning Approach
    Zhao, L.
    Asis-Cruz, J. D.
    Feng, X.
    Wu, Y.
    Kapse, K.
    Largent, A.
    Quistorff, J.
    Lopez, C.
    Wu, D.
    Qing, K.
    Meyer, C.
    Limperopoulos, C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (03) : 448 - 454
  • [35] MR neurography showed brachial plexus abnormalities in syringomyelia with shoulder Charcot arthropathy: a case report
    Chen, Kai
    Deng, Lijing
    She, Hualong
    Hu, Fang
    Li, Tao
    BRITISH JOURNAL OF NEUROSURGERY, 2023, 37 (04) : 717 - 719
  • [36] 3D MR NEUROGRAPHY OF AXILLARY NERVE INJURY: CASE REPORT
    Salvalaggio, A.
    Cacciavillani, M.
    Baldo, M.
    Briani, C.
    Gasparotti, R.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2015, 20 : S26 - S26
  • [37] Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction
    Zhang, Yu
    Peng, Wanlin
    Xiao, Yi
    Ming, Yue
    Ma, Kehang
    Hu, Sixian
    Zeng, Wen
    Zeng, Lingming
    Liang, Zejun
    Zhang, Xiaoyong
    Xia, Chunchao
    Li, Zhenlin
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2500 - 2509
  • [38] Optimized stereo reconstruction using 3D graphics hardware
    Zach, C
    Klaus, A
    Reitinger, B
    Karner, K
    VISION, MODELING, AND VISUALIZATION 2003, 2003, : 119 - +
  • [39] High resolution neurography of the brachial plexus by 3 Tesla magnetic resonance imaging
    Cejas, C.
    Rollan, C.
    Michelin, G.
    Nogues, M.
    RADIOLOGIA, 2016, 58 (02): : 88 - 100
  • [40] Brachial plexus 3D reconstruction from MRI with dissection validation: a baseline study for clinical applications
    Van de Velde, Joris
    Bogaert, Stephanie
    Vandemaele, Pieter
    Huysse, Wouter
    Achten, Eric
    Leijnse, Joris
    De Neve, Wilfried
    Van Hoof, Tom
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (02) : 229 - 236