Impact of patient?s habitus on image quality and quantitative metrics in 18F-FDG PET/CT images

被引:0
|
作者
Zorz, Alessandra [1 ]
D'Alessio, Andrea [2 ]
Guida, Federica [1 ]
Ramadan, Rehema Masaka [3 ,4 ]
Richetta, Elisa [5 ]
Cuppari, Lea [6 ]
Pellerito, Riccardo [7 ]
Sacchetti, Gian Mauro [8 ]
Brambilla, Marco [2 ]
Paiusco, Marta [1 ]
Stasi, Michele [5 ]
Matheoud, Roberta [2 ]
机构
[1] Ist Oncol Veneto IOV, Med Phys Dept, IRCCS, Via Gattamelata 64, Padua, Italy
[2] Univ Hosp Maggiore Della Carita, Med Phys Dept, Cso Mazzini 18, Novara, Italy
[3] Univ Trieste, Dept Med Phys, Via Tiepolo 11, Trieste, Italy
[4] Abdus Salam Int Ctr Theoret Phys ICTP, Str Costiera 11, Trieste, Italy
[5] AO Ordine Mauriziano Torino, Med Phys Dept, Via Magellano 1, Turin, Italy
[6] Ist Oncol Veneto IOV, Nucl Med Dept, IRCCS, Padua, Italy
[7] AO Ordine Mauriziano Torino, Nucl Med Dept, Via Magellano 1, Turin, Italy
[8] Univ Hosp Maggiore Della Carita, Nucl Med Dept, Novara, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 109卷
关键词
Image quality; PET; CT; SUV; SUL; BODY-WEIGHT; FDG;
D O I
10.1016/j.ejmp.2023.102584
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study how the quantitative parameters of 18F-FDG PET imaging change with the emission scan duration (ESD) and the body-mass-index (BMI) in phantom and patients on a time-of-flight (TOF)-PET/CT system. Methods: The image-quality phantom with (b-NEMA-IQ, BMI = 29.2 kg/m2) and without (NEMA-IEC, BMI = 21.4 kg/m2) a 'belt' of water-bags was filled with 18F-FDG activities to obtain nominal standardized uptake values (SUV) of 19, 8 and 5. Patients with BMI <= 25 kg/m2 (L-BMI) and BMI > 25 kg/m2 (H-BMI) were enrolled in this study. Phantom and patients underwent list-mode PET acquisition at 120 s/bed-position. Images reconstructed with clinical protocol and different ESD (120, 90, 75, 60, 45, 30 s) were analysed for comparison of maximum SUV (SUVmax), maximum standardized uptake value lean-body-mass corrected (SULmax) and noise. Results: 79 oncologic patients (45 L-BMI, 44 H-BMI) were analysed. From 90 s to 30 s, an increasing variation of SUVmax and SULmax with respect to the reference 120 s time was observed, from 18% to 60% and from 16% to 37% for phantom and patients, respectively. SUVmax values were significantly higher (+50%) in b-NEMA-IQ than NEMA-IQ phantom and in H-BMI (+33%) than L-BMI patients. No significant difference was found in SULmax for the two BMI categories in both phantom and patients. CV values decreased when increasing ESD, being higher in H-BMI patients (0.13-0.25) and b-NEMA-IQ phantom (0.15-0.28) than in L-BMI patients (0.11-0.21) and NEMA-IQ phantom (0.11-0.20). Conclusions: Reduction of ESD may severely impact on the variations of SUVmax and SULmax in 18F-FDG PET/CT imaging. This study confirms recommendations of using SUL for lesion uptake quantification, being unaffected by BMI variation.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] The comparative performances of 18F-FDG PET/MRI and 18F-FDG PET/CT for the detection of pancreatic neoplasms
    Xing, H.
    Hou, B.
    Zhu, W.
    Ding, H.
    Li, X.
    Hu, Y.
    Xue, H.
    Feng, F.
    Lv, K.
    Wu, X.
    Li, F.
    Jin, Z.
    Li, D.
    Huo, L.
    Zhao, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S501 - S501
  • [42] 18F-FDG PET/CT in the diagnosis of Takayasu's arteritis
    Sargin, Gokhan
    Senturk, Taskin
    Sahin, Ongun
    ARCHIVES OF MEDICAL SCIENCE, 2018, 14 (05) : 1173 - 1174
  • [43] 18F-FDG PET/CT image findings of a dog with adrenocortical carcinoma
    Lee, Dohee
    Yun, Taesik
    Koo, Yoonhoi
    Chae, Yeon
    Chang, Dongwoo
    Yang, Mhan-Pyo
    Kang, Byeong-Teck
    Kim, Hakhyun
    BMC VETERINARY RESEARCH, 2022, 18 (01)
  • [44] Vascular Inflammation Imaging with 18F-FDG PET/CT: When to Image?
    Menezes, Leon J.
    Kotze, Carl W.
    Hutton, Brian F.
    Endozo, Raymondo
    Dickson, John C.
    Cullum, Ian
    Yusuf, Syed W.
    Ell, Peter J.
    Groves, Ashley M.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (06) : 854 - 857
  • [45] The Performance Comparison of 18F-FDG PET/MRI and 18F-FDG PET/CT for the Identification of Pancreatic Neoplasms
    Haiqun Xing
    Haiyan Ding
    Bo Hou
    Zhixin Hao
    Ya Hu
    Wenjia Zhu
    Sayuan Liang
    Feng Feng
    Fang Li
    Yupei Zhao
    Li Huo
    Molecular Imaging and Biology, 2022, 24 : 489 - 497
  • [46] The Performance Comparison of 18F-FDG PET/MRI and 18F-FDG PET/CT for the Identification of Pancreatic Neoplasms
    Xing, Haiqun
    Ding, Haiyan
    Hou, Bo
    Hao, Zhixin
    Hu, Ya
    Zhu, Wenjia
    Liang, Sayuan
    Feng, Feng
    Li, Fang
    Zhao, Yupei
    Huo, Li
    MOLECULAR IMAGING AND BIOLOGY, 2022, 24 (03) : 489 - 497
  • [47] The appearance of Mazabraud’s syndrome on 18F-FDG PET/CT
    Amit Singnurkar
    J. P. Phancao
    Deep S. Chatha
    Jerry Stern
    Skeletal Radiology, 2007, 36 : 1085 - 1089
  • [48] Richter's syndrome: Utility of 18F-FDG PET/CT
    Garcia Vicente, A. M.
    Jimenez Londono, G. A.
    Hernandez Ruiz, B.
    Soriano Castrejon, A.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2013, 32 (02): : 102 - 104
  • [49] Rescue Protocol to Improve the Image Quality of 18F-FDG PET/CT Myocardial Metabolic Imaging
    Sun, Xiao-Xin
    Li, Shuheng
    Wang, Yawen
    Li, Wei
    Wei, Hongxing
    He, Zuo-Xiang
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (05) : 369 - 374
  • [50] Indeterminate pulmonary nodules on CT images in breast cancer patient: The additional value of 18F-FDG PET/CT
    Evangelista, Laura
    Panunzio, Annalori
    Cervino, Anna Rita
    Vinante, Lorenzo
    Al-Nahhas, Adil
    Rubello, Domenico
    Muzzio, Pier Carlo
    Polverosi, Roberta
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (04) : 417 - 424