Impact of patient?s habitus on image quality and quantitative metrics in 18F-FDG PET/CT images

被引:0
|
作者
Zorz, Alessandra [1 ]
D'Alessio, Andrea [2 ]
Guida, Federica [1 ]
Ramadan, Rehema Masaka [3 ,4 ]
Richetta, Elisa [5 ]
Cuppari, Lea [6 ]
Pellerito, Riccardo [7 ]
Sacchetti, Gian Mauro [8 ]
Brambilla, Marco [2 ]
Paiusco, Marta [1 ]
Stasi, Michele [5 ]
Matheoud, Roberta [2 ]
机构
[1] Ist Oncol Veneto IOV, Med Phys Dept, IRCCS, Via Gattamelata 64, Padua, Italy
[2] Univ Hosp Maggiore Della Carita, Med Phys Dept, Cso Mazzini 18, Novara, Italy
[3] Univ Trieste, Dept Med Phys, Via Tiepolo 11, Trieste, Italy
[4] Abdus Salam Int Ctr Theoret Phys ICTP, Str Costiera 11, Trieste, Italy
[5] AO Ordine Mauriziano Torino, Med Phys Dept, Via Magellano 1, Turin, Italy
[6] Ist Oncol Veneto IOV, Nucl Med Dept, IRCCS, Padua, Italy
[7] AO Ordine Mauriziano Torino, Nucl Med Dept, Via Magellano 1, Turin, Italy
[8] Univ Hosp Maggiore Della Carita, Nucl Med Dept, Novara, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 109卷
关键词
Image quality; PET; CT; SUV; SUL; BODY-WEIGHT; FDG;
D O I
10.1016/j.ejmp.2023.102584
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study how the quantitative parameters of 18F-FDG PET imaging change with the emission scan duration (ESD) and the body-mass-index (BMI) in phantom and patients on a time-of-flight (TOF)-PET/CT system. Methods: The image-quality phantom with (b-NEMA-IQ, BMI = 29.2 kg/m2) and without (NEMA-IEC, BMI = 21.4 kg/m2) a 'belt' of water-bags was filled with 18F-FDG activities to obtain nominal standardized uptake values (SUV) of 19, 8 and 5. Patients with BMI <= 25 kg/m2 (L-BMI) and BMI > 25 kg/m2 (H-BMI) were enrolled in this study. Phantom and patients underwent list-mode PET acquisition at 120 s/bed-position. Images reconstructed with clinical protocol and different ESD (120, 90, 75, 60, 45, 30 s) were analysed for comparison of maximum SUV (SUVmax), maximum standardized uptake value lean-body-mass corrected (SULmax) and noise. Results: 79 oncologic patients (45 L-BMI, 44 H-BMI) were analysed. From 90 s to 30 s, an increasing variation of SUVmax and SULmax with respect to the reference 120 s time was observed, from 18% to 60% and from 16% to 37% for phantom and patients, respectively. SUVmax values were significantly higher (+50%) in b-NEMA-IQ than NEMA-IQ phantom and in H-BMI (+33%) than L-BMI patients. No significant difference was found in SULmax for the two BMI categories in both phantom and patients. CV values decreased when increasing ESD, being higher in H-BMI patients (0.13-0.25) and b-NEMA-IQ phantom (0.15-0.28) than in L-BMI patients (0.11-0.21) and NEMA-IQ phantom (0.11-0.20). Conclusions: Reduction of ESD may severely impact on the variations of SUVmax and SULmax in 18F-FDG PET/CT imaging. This study confirms recommendations of using SUL for lesion uptake quantification, being unaffected by BMI variation.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] "Cold" Spondylodiscitis on 18F-FDG PET/CT in a Patient With Myelofibrosis
    Rousseau, Etienne
    Keu, Khun Visith
    CLINICAL NUCLEAR MEDICINE, 2016, 41 (03) : E156 - E158
  • [22] 18F-FDG PET/CT findings in a patient with renal angiomyolipoma
    Tekin, B. Okudan
    Erdogan, A. S.
    Seven, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S814 - S814
  • [23] 18F-FDG PET/CT "superscan" in a patient with immunoblastic lymphoma
    Acevedo-Banez, I.
    De-Bonilla-Damia, A.
    Fernandez-Lopez, R.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2019, 38 (04): : 252 - 253
  • [24] The Performance of 18F-FDG PET and 18F-FDG PET/CT in Detection of Carcinoma of Unknown Primary
    Dong, M.
    Zhao, K.
    Zhao, J.
    Guan, Y.
    Liu, Z.
    Ruan, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S275 - S275
  • [25] 18F-FDG PET and 18F-FDG PET/CT for Assessing Response to Therapy in Esophageal Cancer
    Krause, Bernd J.
    Herrmann, Ken
    Wieder, Hinrich
    zum Bueschenfelde, Christian Meyer
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 89S - 96S
  • [26] Quantitative analysis of image metrics for reduced and standard dose pediatric 18F-FDG PET/MRI examinations
    Zucchetta, Pietro
    Branchini, Marco
    Zorz, Alessandra
    Bodanza, Valentina
    Cecchin, Diego
    Paiusco, Marta
    Bui, Franco
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):
  • [27] 18F-FDG PET/MRI versus 18F-FDG PET/CT for the diagnosis of pituitary adenoma
    Wang, Hao
    Zhao, Xiaobin
    Zang, Jie
    Zhu, Zhaohui
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [28] Clinical impact of 18F-FDG PET/CT in patients with sarcoidosis
    Ambrosini, V.
    Zompatori, M.
    Fasano, L.
    Allegri, V.
    Nanni, C.
    Montini, G.
    Caroli, P.
    Valentini, I.
    Rubello, D.
    Nava, S.
    Fanti, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S214 - S214
  • [29] The impact of 18F-FDG PET/CT in patients with liver metastases
    Chua, Siew C.
    Groves, Ashley M.
    Kayani, Irfan
    Menezes, Leon
    Gacinovic, Svetislav
    Du, Yong
    Bomanji, Jamshed B.
    Ell, Peter J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) : 1906 - 1914
  • [30] Impact of 18F-FDG PET/CT in Predicting Recurrence in Neurolymphomatosis
    Uemichi, Megumi
    Yokoyama, Kota
    Tsuchiya, Junichi
    Terao, Toshiki
    Machida, Youichi
    Matsue, Kosei
    Tateishi, Ukihide
    HEMATO, 2021, 2 (03): : 596 - 606