Impact of patient?s habitus on image quality and quantitative metrics in 18F-FDG PET/CT images

被引:0
|
作者
Zorz, Alessandra [1 ]
D'Alessio, Andrea [2 ]
Guida, Federica [1 ]
Ramadan, Rehema Masaka [3 ,4 ]
Richetta, Elisa [5 ]
Cuppari, Lea [6 ]
Pellerito, Riccardo [7 ]
Sacchetti, Gian Mauro [8 ]
Brambilla, Marco [2 ]
Paiusco, Marta [1 ]
Stasi, Michele [5 ]
Matheoud, Roberta [2 ]
机构
[1] Ist Oncol Veneto IOV, Med Phys Dept, IRCCS, Via Gattamelata 64, Padua, Italy
[2] Univ Hosp Maggiore Della Carita, Med Phys Dept, Cso Mazzini 18, Novara, Italy
[3] Univ Trieste, Dept Med Phys, Via Tiepolo 11, Trieste, Italy
[4] Abdus Salam Int Ctr Theoret Phys ICTP, Str Costiera 11, Trieste, Italy
[5] AO Ordine Mauriziano Torino, Med Phys Dept, Via Magellano 1, Turin, Italy
[6] Ist Oncol Veneto IOV, Nucl Med Dept, IRCCS, Padua, Italy
[7] AO Ordine Mauriziano Torino, Nucl Med Dept, Via Magellano 1, Turin, Italy
[8] Univ Hosp Maggiore Della Carita, Nucl Med Dept, Novara, Italy
关键词
Image quality; PET; CT; SUV; SUL; BODY-WEIGHT; FDG;
D O I
10.1016/j.ejmp.2023.102584
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study how the quantitative parameters of 18F-FDG PET imaging change with the emission scan duration (ESD) and the body-mass-index (BMI) in phantom and patients on a time-of-flight (TOF)-PET/CT system. Methods: The image-quality phantom with (b-NEMA-IQ, BMI = 29.2 kg/m2) and without (NEMA-IEC, BMI = 21.4 kg/m2) a 'belt' of water-bags was filled with 18F-FDG activities to obtain nominal standardized uptake values (SUV) of 19, 8 and 5. Patients with BMI <= 25 kg/m2 (L-BMI) and BMI > 25 kg/m2 (H-BMI) were enrolled in this study. Phantom and patients underwent list-mode PET acquisition at 120 s/bed-position. Images reconstructed with clinical protocol and different ESD (120, 90, 75, 60, 45, 30 s) were analysed for comparison of maximum SUV (SUVmax), maximum standardized uptake value lean-body-mass corrected (SULmax) and noise. Results: 79 oncologic patients (45 L-BMI, 44 H-BMI) were analysed. From 90 s to 30 s, an increasing variation of SUVmax and SULmax with respect to the reference 120 s time was observed, from 18% to 60% and from 16% to 37% for phantom and patients, respectively. SUVmax values were significantly higher (+50%) in b-NEMA-IQ than NEMA-IQ phantom and in H-BMI (+33%) than L-BMI patients. No significant difference was found in SULmax for the two BMI categories in both phantom and patients. CV values decreased when increasing ESD, being higher in H-BMI patients (0.13-0.25) and b-NEMA-IQ phantom (0.15-0.28) than in L-BMI patients (0.11-0.21) and NEMA-IQ phantom (0.11-0.20). Conclusions: Reduction of ESD may severely impact on the variations of SUVmax and SULmax in 18F-FDG PET/CT imaging. This study confirms recommendations of using SUL for lesion uptake quantification, being unaffected by BMI variation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Improved image resolution on thoracic carcinomas by quantitative 18F-FDG coincidence SPECT/CT in comparison to 18F-FDG PET/CT
    Yuming Zheng
    Chaoling Jin
    Huijuan Cui
    Haojie Dai
    Jue Yan
    Pingping Han
    Bailing Hsu
    The Journal of Biomedical Research, 2020, 34 (04) : 309 - 317
  • [2] Improved image resolution on thoracic carcinomas by quantitative 18F-FDG coincidence SPECT/CT in comparison to 18F-FDG PET/CT
    Zheng, Yuming
    Jin, Chaoling
    Cui, Huijuan
    Dai, Haojie
    Yan, Jue
    Han, Pingping
    Hsu, Bailing
    JOURNAL OF BIOMEDICAL RESEARCH, 2020, 34 (04): : 309 - 317
  • [3] Impact of advanced image reconstruction algorithm on qualitative and quantitative oncological 18F-FDG PET/CT
    Shiri, I.
    Ghafarian, P.
    Bitarafan, A.
    BakhshaieshKaram, M.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S509 - S509
  • [4] The Impact of Overlap Size on Image Quality of 18F-FDG PET/CT: Phantom and Clinical Study
    Zahedi, S. Gholami
    Ghafarian, P.
    Aghamiri, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S345 - S346
  • [5] Quantitative 18F-FDG PET/CT image features for the evaluation of tumor response
    Lu, Wei
    Tan, Shan
    Zhang, Hao
    Chen, Wengen
    Kligerman, Seth
    Suntharalingam, Mohan
    DSouza, Warren
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] 18F-FDG PET/CT findings in a patient with Cowden's syndrome
    Oksuzoglu, K.
    Ones, T.
    Ilce, H. T.
    Dede, F.
    Turoglu, H. T.
    Inanir, S.
    Erdil, T. Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S651 - S652
  • [7] 18F-FDG PET/CT Findings of a Patient with Wegener's Granulomatosis
    Ozdemir , E.
    Yildirim-Poyraz, N.
    Senturk, A.
    Uz, E.
    Keskin, M.
    Kandemir, Z.
    Turkolmez, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S647 - S647
  • [8] The Impact of Obesity on 18F-FDG PET-CT tumor metrics in Oesophageal Adenocarcinoma?
    Dennan, S.
    Malik, V.
    Doyle, S.
    Gilmartin, N.
    Reynolds, J. V.
    Johnston, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S99 - S99
  • [9] 18F-FDG PET/CT Findings in a Patient With Neurosarcoidosis
    Chen, Xueqi
    Chen, Guoqian
    Fu, Zhanli
    Li, Qian
    CLINICAL NUCLEAR MEDICINE, 2020, 45 (08) : 640 - 641
  • [10] Quantitative Comparison of Image Quality and Standardized Uptake Values for PET/CT and PET/MR - a Phantom Study with 18F-FDG
    Karlberg, A. M.
    Saether, O.
    Lohmann, K.
    Eikenes, L.
    Goa, P. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S254 - S254