Diagnostic performance of real time PCR for the detection of Mycobacterium tuberculosis in cerebrospinal fluid samples

被引:2
|
作者
Krishnakumariamma, Krishnapriya [1 ]
Ellappan, Kalaiarasan [1 ]
Muthuraj, Muthaiah [2 ]
Tamilarasu, Kadhiravan [3 ]
Kumar, Saka Vinod [4 ]
Joseph, Noyal Mariya [1 ]
机构
[1] Jawaharlal Inst Postgrad Med Educ & Res JIPMER, Dept Microbiol, Pondicherry, India
[2] Govt Hosp Chest Dis, Intermediate Reference Lab, Pondicherry, India
[3] Jawaharlal Inst Postgrad Med Educ & Res JIPMER, Dept Med, Pondicherry, India
[4] Jawaharlal Inst Postgrad Med Educ & Res JIPMER, Dept Pulm Med, Pondicherry, India
关键词
Mycobacterium tuberculosis; Tuberculous meningitis; Real time PCR; Xpert MTB; RIF; POLYMERASE-CHAIN-REACTION; XPERT MTB/RIF ASSAY; LINE PROBE ASSAY; MENINGITIS; IS6110; SYSTEM; COPY;
D O I
10.1016/j.ijmmb.2022.12.012
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Purpose: We aimed this study to standardize real time - polymerase chain reaction (RT-PCR) for the detection of Mycobacterium tuberculosis (Mtb) in cerebrospinal fluid (CSF) samples and compare its diagnostic performance with GeneXpert (Xpert), Mycobacteria Growth Indicator Tube (MGIT) and Multiplex PCR (MPCR) for tuberculous meningitis (TBM).Methodology: A total of 217 CSF samples were obtained from patients with suspected TBM during the study period between January 2019 and December 2021. The optimal cycle threshold (CT) of RT-PCR was determined by comparing different gene targets of Mtb (IS6110, 16SrRNA, HSP65 and Ag85B). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) was determined for RT-PCR, Xpert, MGIT960 and MPCR. Diagnostic accuracy of these assays was compared by using clinical diagnosis as reference standard.Results: IS6110RT-PCR was found to be highly sensitive as compared to other gene targets. Sensitivities of IS6110RT-PCR, MPCR, Xpert and MGIT against a reference standard of definite, probable and possible TBM were 36.7%, 21.1%, 16.7% and 6.7%, respectively; specificities were 97.6%, 100%, 100% and 100%, respectively. Xpert, RT-PCR, MPCR and MGIT960 detected 6.91% (n = 15), 5.99% (n = 13), 5.99% (n = 13) and 2.76% (n = 6) of definite TBM, respectively. RT-PCR detected 6.45% (n = 14) and 2.76% (n = 6) of possible TBM and probable TBM, respectively and MPCR detected 1.38% (n = 3) of possible and probable TBM each. Conclusion: IS6110RT-PCR is highly sensitive for primary screening of suspected TB cases, which may help clinicians to start appropriate patient's treatment with clinical suspicion of TBM.
引用
收藏
页码:7 / 11
页数:5
相关论文
共 50 条
  • [41] Evaluation on the Detection of Mycobacterium Tuberculosis in Clinical Samples by PCR and DNA Probe
    吴雪琼
    庄玉辉
    张晓刚
    李国利
    ChineseMedicalSciencesJournal, 1996, (04) : 208 - 208
  • [42] Diagnostic Utility of Real-Time PCR for Mycobacterium tuberculosis Complex Infection in Routine Clinical Practice
    Shin, S.
    Park, M.
    Song, W.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (02): : S20 - S21
  • [43] A real-time PCR assay for detection of isoniazid resistance in Mycobacterium tuberculosis clinical isolates
    Rindi, L
    Bianchi, L
    Tortoli, E
    Lari, N
    Bonanni, D
    Garzelli, C
    JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 55 (03) : 797 - 800
  • [44] Comparison of the Xpert MTB/RIF Assay and Real-time PCR for the Detection of Mycobacterium tuberculosis
    Kim, Min Jin
    Nam, You Sun
    Cho, Sun Young
    Park, Tae Sung
    Lee, Hee Joo
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2015, 45 (03): : 327 - 332
  • [45] Real-time PCR and Amplified MTD® for rapid detection of Mycobacterium tuberculosis in pulmonary specimens
    Chen, X.
    Yang, Q.
    Kong, H.
    Chen, Y.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2012, 16 (02) : 235 - 239
  • [46] Rapid detection of Mycobacterium tuberculosis complex by real-time PCR in sputum samples and its use in the routine diagnosis in a reference laboratory
    Watanabe Pinhata, Juliana Maira
    Cergole-Novella, Maria Cecilia
    dos Santos Carmo, Andreia Moreira
    Ferro e Silva, Regina Ruivo
    Ferrazoli, Lucilaine
    Sacchi, Claudio Tavares
    de Oliveira, Rosangela Siqueira
    JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 : 1040 - 1045
  • [47] A duplex real-time PCR for the detection of Streptococcus pneumoniae and Neisseria meningitidis in cerebrospinal fluid
    Diawara, Idrissa
    Katfy, Khalid
    Zerouali, Khalid
    Belabbes, Houria
    Elmdaghri, Naima
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2016, 10 (01): : 53 - 61
  • [48] Effectiveness of an Integrated Real-Time PCR Method for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Extrapulmonary Samples in an Area of Low Tuberculosis Prevalence
    Moure, Raquel
    Martin, Rogelio
    Alcaide, Fernando
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (02) : 513 - 515
  • [49] Detection of Mycobacteria, Mycobacterium avium Subspecies, and Mycobacterium tuberculosis Complex by a Novel Tetraplex Real-Time PCR Assay
    Sevilla, Iker A.
    Molina, Elena
    Elguezabal, Natalia
    Perez, Valentin
    Garrido, Joseba M.
    Justea, Ramn A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (03) : 930 - 940
  • [50] Comparison of Diagnostic Performance of Three Real-Time PCR Kits for Detecting Mycobacterium Species
    Cho, Sun Young
    Kim, Min Jin
    Suh, Jin-Tae
    Lee, Hee Joo
    YONSEI MEDICAL JOURNAL, 2011, 52 (02) : 301 - 306