Non-contact human respiratory rate measurement under dark environments by low-light video enhancement

被引:2
|
作者
Wang, Haipeng [1 ]
Zhang, Shuai [2 ]
机构
[1] Jiangsu Coll Engn & Technol, Sch Intelligent Mfg, Nantong 226006, Peoples R China
[2] Zhejiang Univ, Ctr Psychol Sci, Hangzhou, Peoples R China
关键词
Non-contact measurement; Dark environment; Retinex; Video enhancement;
D O I
10.1016/j.bspc.2023.104874
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A non-contact human respiratory rate measurement algorithm under dark environments is proposed in this study. The algorithm takes the low-light video as input, which includes four steps: time-domain preprocessing, space-domain preprocessing, image enhancement, and respiratory rate measurement. Firstly, the time-domain preprocessing and space-domain preprocessing run in turn to filter out the image noise and environment interference. Then, a Retinex-based image enhancement algorithm works for image enhancement. The human respiratory rate is measured at last. Experiments on a self-made dataset show that an average increase of 2.3 % in accuracy can be obtained by the proposed method. Specifically, high-precision measurement results can be achieved when the light intensity is not less than 200 lux and the detection distance is not far from 1.5 m.
引用
收藏
页数:7
相关论文
共 40 条
  • [21] Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via RGB Signal Measurement
    Massaroni, Carlo
    Lo Presti, Daniela
    Formica, Domenico
    Silvestri, Sergio
    Schena, Emiliano
    SENSORS, 2019, 19 (12)
  • [22] Automatic non-contact monitoring of the respiratory rate of neonates using a structured light camera
    Gleichauf, Johanna
    Niebler, Christine
    Koelpin, Alexander
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4118 - 4121
  • [23] Non-contact interferometric measurement of the vibrations parameters under diffuse light reflection
    Tavrov, AV
    ULTRAHIGH- AND HIGH-SPEED PHOTOGRAPHY AND IMAGE-BASED MOTION MEASUREMENT, 1997, 3173 : 295 - 297
  • [24] Non-contact, synchronous dynamic measurement of respiratory rate and heart rate based on dual sensitive regions
    Bing Wei
    Xuan He
    Chao Zhang
    Xiaopei Wu
    BioMedical Engineering OnLine, 16
  • [25] Non-contact, synchronous dynamic measurement of respiratory rate and heart rate based on dual sensitive regions
    Wei, Bing
    He, Xuan
    Zhang, Chao
    Wu, Xiaopei
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [26] Non-contact heart rate measurement from face video sequences using SIFT and FastICA
    Biradar, Hemlata G.
    Gawande, Jayanand P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2024, 45 (01)
  • [27] Non-contact heart rate measurement from face video based on group sparse representation
    Ou, Weihua
    Chen, Longbao
    Xiong, Jiahao
    Han, Jie
    Zeng, Wu
    Gou, Jianping
    DIGITAL SIGNAL PROCESSING, 2024, 144
  • [28] Self-adaptive signal separation for non-contact heart rate estimation from facial video in realistic environments
    Liu, Xuenan
    Yang, Xuezhi
    Jin, Jing
    Li, Liangshan
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (06)
  • [29] Non-Uniform Low-Light Face Image Enhancement Based on Dark Channel Prior and Image Uniform Posterior
    Zhang, Bo-Yu
    Zhang, Qing-Chun
    Zhang, Wen-Ying
    IEEE ACCESS, 2024, 12 : 85724 - 85734
  • [30] Non-Contact Heart Rate Measurement From Facial Video Data Using a 2D-VMD Scheme
    Das, Mousumi
    Choudhary, Tilendra
    Bhuyan, M. K.
    Sharma, L. N.
    IEEE SENSORS JOURNAL, 2022, 22 (11) : 11153 - 11161