Accurate calibration for fringe projection profilometry based on an improved subpixel mapping with local gray distribution

被引:2
|
作者
Liu, Bin [1 ,2 ]
He, Xinxin [3 ]
Wang, Chunliu [1 ]
Wang, Sen [1 ]
Wu, Guanhao [2 ]
机构
[1] Tianjin Univ Technol, Sch Elect Engn & Automat, Tianjin Key Lab Control Theory & Applicat Complica, Tianjin 300384, Peoples R China
[2] Tsinghua Univ, Dept Precis Instruments, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China
[3] Hainan Coll Software Technol, Sch Network Engn, Qionghai 571400, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
CAMERA; ALGORITHMS; SYSTEM;
D O I
10.1364/JOSAA.501765
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fringe projection profilometry is an efficient and accurate technique for three-dimensional (3D) measurement to calibrate a camera and projector setup. The feature centers of circles on a calibration board are extracted on the camera image plane and mapped to the projector image plane during the calibration procedure. The accuracy of the mapping between camera pixels and projector pixels is crucial to the calibration accuracy, which directly affects the measurement precision of the system. In this paper, we investigate an improved subpixel mapping with local gray distribution from the camera to the projector. The mapped pixels and their gray values are regarded as a set of 3D grayscale space points. The subpixel coordinates of the feature centers on the projector image plane are obtained by directly processing the 3D points. The entire procedure retains the subpixel precision. Calibration experiments were designed to verify the feasibility of our calibration method, which was compared to three existing methods. The reprojection errors and object-space errors were used to evaluate the calibration accuracy of the methods. Additionally, measurement experiments of displacement and in-plane distance were employed to verify the calibration results of the methods. Compared to the three existing methods, we believe our method can improve the calibration accuracy for fringe projection profilometry. (c) 2023 Optica Publishing Group
引用
收藏
页码:2164 / 2176
页数:13
相关论文
共 50 条
  • [41] Simplification of high order polynomial calibration model for fringe projection profilometry
    Yu, Liandong
    Zhang, Wei
    Li, Weishi
    Pan, Chengliang
    Xia, Haojie
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (10)
  • [42] Flexible Calibration Method for Fringe Projection Profilometry System using Spheres
    Yu, Jian
    Da, Feipeng
    Wang, Chenxing
    Gai, Shaoyan
    SEVENTH INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONIC ENGINEERING (ICOPEN 2019), 2019, 11205
  • [43] Sub-pixel projector calibration method for fringe projection profilometry
    Zhang, Wei
    Li, Weishi
    Yu, Liandong
    Luo, Hui
    Zhao, Huining
    Xia, Haojie
    OPTICS EXPRESS, 2017, 25 (16): : 19158 - 19169
  • [44] FPP-SLAM: indoor simultaneous localization and mapping based on fringe projection profilometry
    Zhao, Yang
    Yu, Haotian
    Zhang, Kai
    Zheng, Yucheng
    Zhang, Yi
    Zheng, Dongliang
    Han, Jing
    OPTICS EXPRESS, 2023, 31 (04) : 5853 - 5871
  • [45] Quaternary gray-code phase unwrapping for binary fringe projection profilometry
    He, Xiaoyu
    Zheng, Dongliang
    Kemao, Qian
    Christopoulos, George
    OPTICS AND LASERS IN ENGINEERING, 2019, 121 : 358 - 368
  • [46] A ternary complementary Gray code phase unwrapping method in fringe projection profilometry
    Wei, Hao
    Li, Hongru
    Liu, Jiangtao
    Deng, Guoliang
    Zhou, Shouhuan
    JOURNAL OF APPLIED PHYSICS, 2024, 135 (14)
  • [47] Fringe projection profilometry by ternary-gray encoded phase unwrapping method
    Zhang A.
    Sun Y.
    Gao N.
    Meng Z.
    Zhang Z.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2022, 30 (05): : 518 - 526
  • [48] A fast and accurate gamma correction based on Fourier spectrum analysis for digital fringe projection profilometry
    Ma, S.
    Quan, C.
    Zhu, R.
    Chen, L.
    Li, B.
    Tay, C. J.
    OPTICS COMMUNICATIONS, 2012, 285 (05) : 533 - 538
  • [49] Calibration method for fringe projection profilometry with complex distortion based on B-spline surface
    Qi, Cheng
    Feng, Pan
    OPTICS AND LASERS IN ENGINEERING, 2024, 180
  • [50] Accurate Calibration of a Fringe Projection System by Considering Telecentricity
    Haskamp, Klaus
    Kaestner, Markus
    Reithmeier, Eduard
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VII, 2011, 8082