摘要
Fringe projection profilometry is an efficient and accurate technique for three-dimensional (3D) measurement to calibrate a camera and projector setup. The feature centers of circles on a calibration board are extracted on the camera image plane and mapped to the projector image plane during the calibration procedure. The accuracy of the mapping between camera pixels and projector pixels is crucial to the calibration accuracy, which directly affects the measurement precision of the system. In this paper, we investigate an improved subpixel mapping with local gray distribution from the camera to the projector. The mapped pixels and their gray values are regarded as a set of 3D grayscale space points. The subpixel coordinates of the feature centers on the projector image plane are obtained by directly processing the 3D points. The entire procedure retains the subpixel precision. Calibration experiments were designed to verify the feasibility of our calibration method, which was compared to three existing methods. The reprojection errors and object-space errors were used to evaluate the calibration accuracy of the methods. Additionally, measurement experiments of displacement and in-plane distance were employed to verify the calibration results of the methods. Compared to the three existing methods, we believe our method can improve the calibration accuracy for fringe projection profilometry. (c) 2023 Optica Publishing Group
引用
收藏
页码:2164 / 2176
页数:13
相关论文
共 50 条
  • [21] A Novel In Situ Calibration Method Based on Virtual Planes for Fringe Projection Profilometry
    Zhang, Bingwei
    Jiang, Kaiyong
    Lin, Junyi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 8
  • [22] Unsupervised-learning-based calibration method in microscopic fringe projection profilometry
    Yuan, Quan
    Wu, Jingjing
    Zhang, Huanlong
    Yu, Jinmiao
    Ye, Yunpeng
    APPLIED OPTICS, 2023, 62 (27) : 7299 - 7315
  • [23] Coaxial projection profilometry based on speckle and fringe projection
    Liu, Cong
    Chen, Lujie
    He, Xiaoyuan
    Vu Duc Thang
    Kofidis, Theodoros
    OPTICS COMMUNICATIONS, 2015, 341 : 228 - 236
  • [24] Calibration method for fringe projection profilometry with a binary defocusing technique
    Xuexing Li
    Miao Gong
    Zhao Zhang
    Zhijiang Zhang
    Chen Yang
    Optical Review, 2017, 24 : 495 - 504
  • [25] Deep learning-based fringe modulation-enhancing method for accurate fringe projection profilometry
    Yu, Haotian
    Zheng, Dongliang
    Fu, Jiaan
    Zhang, Yi
    Zuo, Chao
    Han, Jing
    OPTICS EXPRESS, 2020, 28 (15) : 21692 - 21703
  • [26] A novel calibration method for arbitrary fringe projection profilometry system
    Kang, Xin
    Li, Tongbin
    Sia, Bernard
    Li, Junrui
    Yang, Lianxiang
    OPTIK, 2017, 148 : 227 - 237
  • [27] Least-squares calibration method for fringe projection profilometry
    Guo, HW
    He, HT
    Yu, YJ
    Chen, MY
    OPTICAL ENGINEERING, 2005, 44 (03) : 1 - 9
  • [28] Flexible calibration method for telecentric fringe projection profilometry systems
    Rao, Li
    Da, Feipeng
    Kong, Weiqi
    Huang, Heming
    OPTICS EXPRESS, 2016, 24 (02): : 1222 - 1237
  • [29] A calibration method immune to the projector errors in fringe projection profilometry
    Zhang, Ruihua
    Guo, Hongwei
    APPLIED OPTICAL METROLOGY II, 2017, 10373
  • [30] Calibration method for fringe projection profilometry with a binary defocusing technique
    Li, Xuexing
    Gong, Miao
    Zhang, Zhao
    Zhang, Zhijiang
    Yang, Chen
    OPTICAL REVIEW, 2017, 24 (04) : 495 - 504