3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures

被引:0
|
作者
Li, Xian [1 ,2 ]
Wang, Xiao-ke [1 ]
Yu, Lian-kui [2 ]
Zhang, Chao [2 ]
Zhao, Ming-ming [2 ]
Yan, Jun [2 ]
Han, Li-ren [2 ]
机构
[1] Weifang Med Univ, Sch Clin Med, Weifang, Peoples R China
[2] Liaocheng Peoples Hosp, Dept Orthopaed Surg, Liaocheng, Peoples R China
关键词
Calcaneal fracture; Percutaneous screw fixation; Sustentaculum tali; Digital measurement; SANDERS TYPE-II; PLACEMENT; FIXATION;
D O I
10.1186/s12891-023-06748-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process. Methods We retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated. Results The mean maximum diameter of the PTAS screw was 42.20 +/- 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 +/- 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm similar to 19.81 +/- 2.08 mm. The mean maximum lengths of APC screws was 44.69 +/- 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72 degrees +/- 2.15 degrees to 20.52 degrees +/- 3.77 degrees. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 +/- 0.85 mm, the mean maximum lengths of screws was 65.31 +/- 4.76 mm. We found gender- dependent differences for the mean maximum diameter and the maximum length of the three screws. Conclusions The study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of the Conventional Surgery and the Surgery Assisted by 3d Printing Technology in the Treatment of Calcaneal Fractures
    Zheng, Wenhao
    Tao, Zhenyu
    Lou, Yiting
    Feng, Zhenhua
    Li, Hang
    Cheng, Liang
    Zhang, Hui
    Wang, Jianshun
    Guo, Xiaoshan
    Chen, Hua
    JOURNAL OF INVESTIGATIVE SURGERY, 2018, 31 (06) : 557 - 567
  • [42] A minimally invasive sinus tarsi approach with percutaneous plate and screw fixation for intra-articular calcaneal fractures
    Xia, Shengli
    Wang, Xiuhui
    Lu, Yaogang
    Wang, Huizhong
    Wu, Zuming
    Wang, Ziping
    INTERNATIONAL JOURNAL OF SURGERY, 2013, 11 (10) : 1087 - 1091
  • [43] Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation
    Takao, Masaki
    Hamada, Hidetoshi
    Sakai, Takashi
    Sugano, Nobuhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 189 - 195
  • [44] Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion
    Ito, Yasuo
    Sugimoto, Yoshihisa
    Tomioka, Masao
    Hasegawa, Yasuhiro
    Nakago, Kie
    Yagata, Yukihisa
    JOURNAL OF NEUROSURGERY-SPINE, 2008, 9 (05) : 450 - 453
  • [45] Computer assisted screw insertion into real 3D rapid prototyping pelvis models
    Peters, P
    Langlotz, F
    Nolte, LP
    CLINICAL BIOMECHANICS, 2002, 17 (05) : 376 - 382
  • [46] Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation
    Masaki Takao
    Hidetoshi Hamada
    Takashi Sakai
    Nobuhiko Sugano
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 189 - 195
  • [47] Use of 3D Navigation in Subaxial Cervical Spine Lateral Mass Screw Insertion
    Arab, Abdullah
    Alkherayf, Fahad
    Sachs, Adam
    Wai, Eugene K.
    JOURNAL OF NEUROLOGICAL SURGERY REPORTS, 2018, 79 (01) : e1 - e8
  • [48] 3D Extrusion Simulation of the Single Screw Head and Optimization Design
    Liu, W. -W.
    Xu, J. -J.
    Chen, Y.
    Wang, Z. -T.
    SIXTH INTERNATIONAL CONFERENCE ON NONLINEAR MECHANICS (ICNM-VI), 2013, : 145 - 149
  • [49] 3D printed guide-assisted percutaneous screw fixation for minimally displaced scaphoid waist fractures with delayed diagnosis or presentation
    Rong, Cunmin
    Zhang, Qinglin
    Zhu, Shaobo
    Zhang, Guanghui
    Zeng, Junhao
    Han, Qingluan
    Guo, Yang
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [50] 3D printed guide-assisted percutaneous screw fixation for minimally displaced scaphoid waist fractures with delayed diagnosis or presentation
    Cunmin Rong
    Qinglin Zhang
    Shaobo Zhu
    Guanghui Zhang
    Junhao Zeng
    Qingluan Han
    Yang Guo
    BMC Musculoskeletal Disorders, 25