3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures

被引:0
|
作者
Li, Xian [1 ,2 ]
Wang, Xiao-ke [1 ]
Yu, Lian-kui [2 ]
Zhang, Chao [2 ]
Zhao, Ming-ming [2 ]
Yan, Jun [2 ]
Han, Li-ren [2 ]
机构
[1] Weifang Med Univ, Sch Clin Med, Weifang, Peoples R China
[2] Liaocheng Peoples Hosp, Dept Orthopaed Surg, Liaocheng, Peoples R China
关键词
Calcaneal fracture; Percutaneous screw fixation; Sustentaculum tali; Digital measurement; SANDERS TYPE-II; PLACEMENT; FIXATION;
D O I
10.1186/s12891-023-06748-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process. Methods We retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated. Results The mean maximum diameter of the PTAS screw was 42.20 +/- 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 +/- 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm similar to 19.81 +/- 2.08 mm. The mean maximum lengths of APC screws was 44.69 +/- 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72 degrees +/- 2.15 degrees to 20.52 degrees +/- 3.77 degrees. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 +/- 0.85 mm, the mean maximum lengths of screws was 65.31 +/- 4.76 mm. We found gender- dependent differences for the mean maximum diameter and the maximum length of the three screws. Conclusions The study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion
    Deng, Ting
    Jiang, Minghui
    Lei, Qing
    Cai, Lihong
    Chen, Li
    COMPUTER ASSISTED SURGERY, 2016, 21 (01) : 143 - 149
  • [32] Internal fixation of calcaneal fractures with intraoperative 3D X-ray monitoring
    Porte, T.
    Haustedt, N.
    Queitsch, C.
    Juergens, C.
    TRAUMA UND BERUFSKRANKHEIT, 2005, 7 : S162 - S166
  • [33] Improved therapy of calcaneal fractures by intraoperative 3D-fluoroscopy and locked-screw plate fixation
    Queitsch C.
    Schulz A.P.
    Haustedt N.
    Simon L.
    Fuchs S.
    European Journal of Trauma, 2006, 32 (5): : 471 - 476
  • [34] Clinical Outcome of Tongue Type Intra-Articular Calcaneal Fractures Managed with Percutaneous Screw Fixation
    Siddiqui, Adeel Ahmed
    Rajput, Irfan Muhammad
    Khaskheli, Javed Hussain
    Pathani, Muhammad Younis
    Adeel, Mariyam
    Khalil, Hina
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (03): : 1063 - 1066
  • [35] The treatment of calcaneal fracture with percutaneous poking reduction through the gap of fractures and internal fixation with cannulated screw
    Zhang Hanqing
    Xiao Man
    Yu Zuguang
    Liang Bo
    Wang Ke
    Yang Yang
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 50 - 50
  • [36] 3D simulation of complex fractures with a simple mesh
    Wu, Jie
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2022, 123 (16) : 3713 - 3732
  • [37] A novel manipulator for 3D ultrasound guided percutaneous needle insertion
    Bassan, H.
    Hayes, T.
    Patel, R. V.
    Moallem, M.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 617 - 622
  • [38] Establishment of fluoroscopy views and standardized procedure of percutaneous magic screw insertion for acetabulum fractures
    Li, Jiantao
    Li, Zhirui
    Wang, Xiang
    Zhang, Gongzi
    Peng, Ye
    Zhang, Shuwei
    Tang, Peifu
    Zhang, Lihai
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [39] Establishment of fluoroscopy views and standardized procedure of percutaneous magic screw insertion for acetabulum fractures
    Jiantao Li
    Zhirui Li
    Xiang Wang
    Gongzi Zhang
    Ye Peng
    Shuwei Zhang
    Peifu Tang
    Lihai Zhang
    BMC Musculoskeletal Disorders, 19
  • [40] Maintenance of Integrity of Upper Facet Joints during Simulated Percutaneous Pedicle Screw Insertion Using 2D versus 3D Planning
    Archavlis, Eleftherios
    Ringel, Florian
    Kantelhardt, Sven
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2019, 80 (04) : 269 - 276