Scanning SQUID-on-tip microscope in a top-loading cryogen-free dilution refrigerator

被引:6
|
作者
Zhou, Haibiao [1 ]
Auerbach, Nadav [1 ]
Roy, Indranil [1 ]
Bocarsly, Matan [1 ]
Huber, Martin E. [2 ]
Barick, Barun [1 ]
Pariari, Arnab [1 ]
Hucker, Markus [1 ]
Lim, Zhi Shiuh [3 ]
Ariando, A. [3 ]
Berdyugin, Alexey I. [4 ,5 ]
Xin, Na [4 ,5 ]
Rappaport, Michael [6 ]
Myasoedov, Yuri [1 ]
Zeldov, Eli [1 ]
机构
[1] Weizmann Inst Sci, Dept Condensed Matter Phys, IL-7610001 Rehovot, Israel
[2] Univ Colorado Denver, Dept Phys & Elect Engn, Denver, CO 80204 USA
[3] Natl Univ Singapore, Dept Phys, Singapore, Singapore
[4] Univ Manchester, Sch Phys & Astron, Manchester M13 9PL, England
[5] Univ Manchester, Natl Graphene Inst, Manchester M13 9PL, England
[6] Weizmann Inst Sci, Dept Phys Core Facil, IL-7610001 Rehovot, Israel
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 05期
基金
以色列科学基金会; 欧洲研究理事会; 新加坡国家研究基金会;
关键词
QUANTUM INTERFERENCE DEVICE; DISSIPATION; INSULATOR;
D O I
10.1063/5.0142073
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The scanning superconducting quantum interference device (SQUID) fabricated on the tip of a sharp quartz pipette (SQUID-on-tip) has emerged as a versatile tool for the nanoscale imaging of magnetic, thermal, and transport properties of microscopic devices of quantum materials. We present the design and performance of a scanning SQUID-on-tip microscope in a top-loading probe of a cryogen-free dilution refrigerator. The microscope is enclosed in a custom-made vacuum-tight cell mounted at the bottom of the probe and is suspended by springs to suppress vibrations caused by the pulse tube cryocooler. Two capillaries allow for the in situ control of helium exchange gas pressure in the cell that is required for thermal imaging. A nanoscale heater is used to create local temperature gradients in the sample, which enables quantitative characterization of relative vibrations between the tip and the sample. The spectrum of the vibrations shows distinct resonant peaks with a maximal power density of about 27 nm/Hz(1/2) in the in-plane direction. The performance of the SQUID-on-tip microscope is demonstrated by magnetic imaging of the MnBi2Te4 magnetic topological insulator, magnetization and current distribution imaging in a SrRuO3 ferromagnetic oxide thin film, and thermal imaging of dissipation in graphene.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Systematic Vibration Studies on a Cryogen-Free He/He Dilution Refrigerator for X-ray Spectroscopy at Storage Rings
    Scholz, P. A.
    Kraft-Bermuth, S.
    Andrianov, V.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2016, 184 (3-4) : 576 - 582
  • [42] A Compact Piezo-Drive Rotatable Scanning Tunneling Microscope in a 12 T Cryogen-Free Magnet
    Liu, Junwei
    Li, Zihao
    Wu, Dan
    Zheng, Shaofeng
    Gao, Yue
    Yang, Shiwei
    Wang, Jihao
    Zhang, Jing
    Feng, Qiyuan
    Hou, Yubin
    Meng, Wenjie
    Lu, Yalin
    Lu, Qingyou
    MICROSCOPY RESEARCH AND TECHNIQUE, 2025, 88 (04) : 1034 - 1043
  • [43] A low noise cryogen-free scanning tunneling microscope-superconducting magnet system with vacuum sample transfer
    Chaudhary, Saurabh
    Panda, Janmey Jay
    Mundlia, Suman
    Mathimalar, S.
    Ahmedof, Aathif
    Raman, Karthik, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (02):
  • [44] Transition edge sensor-energy-dispersive spectrometer (TES-EDS) using a cryogen-free dilution refrigerator for material analysis
    Tanaka, K
    Odawara, A
    Nagata, A
    Ikeda, M
    Baba, Y
    Nakayama, S
    Chinone, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 737 - 739
  • [45] Atomically resolved probe-type scanning tunnelling microscope for use in harsh vibrational cryogen-free superconducting magnet
    Meng Wenjie
    Wang Jihao
    Hou Yubin
    Sui Mengqiao
    Zhou Haibiao
    Wang Junting
    Wu Gang
    Zhang Jing
    Chen Fangchu
    Luo Xuan
    Sun Yupin
    Li Junyun
    Lu Qingyou
    ULTRAMICROSCOPY, 2019, 205 : 20 - 26
  • [46] TOP-LOADING HIGH-POWER DILUTION REFRIGERATOR FOR RADIOPHYSICAL STUDIES AT T LESS-THAN-OR-EQUAL-TO 0.1-K
    GOLIK, AV
    TARAPOV, SI
    CRYOGENICS, 1992, 32 (03) : 330 - 331
  • [47] Development of a cryogen-free sub-3 K low-temperature scanning probe microscope by remote liquefaction scheme
    Ma, Ruisong
    Li, Hao
    Shi, Chenshuai
    Wang, Fan
    Lei, Le
    Huang, Yuanzhi
    Liu, Yani
    Shan, Huan
    Liu, Li
    Huang, Shesong
    Niu, Zhi-Chuan
    Huan, Qing
    Gao, Hong-Jun
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (09):
  • [48] JDry-100-ASTRA, a cryogen-free 3He-4He dilution refrigerator for ground-based Cosmic Microwave Background astronomy
    Shvarts, Vladimir
    Zhao, Zuyu
    Jirmanus, Munir
    Battiston, Roberto
    Calvo, Martino
    de Bernardis, Paolo
    de Petris, Marco
    Giordano, Claudia
    Masi, Silvia
    Mezzena, Renato
    26TH INTERNATIONAL CONFERENCE ON LOW TEMPERATURE PHYSICS (LT26), PTS 1-5, 2012, 400
  • [49] JDry-100-ASTRA, a cryogen-free 3He-4He dilution refrigerator for ground-based cosmic microwave background astronomy
    Shvarts, Vladimir
    Zhao, Zuyu
    Jirmanus, Munir
    Battiston, Roberto
    Calvo, Martino
    De Bernardis, Paolo
    De Petris, Marco
    Giordano, Claudia
    Masi, Silvia
    Mezzena, Renato
    Journal of Physics: Conference Series, 2012, 400 (PART 4)
  • [50] Cryogen-free scanning gate microscope for the characterization of Si/Si0.7Ge0.3 quantum devices at milli-Kelvin temperatures
    Oh, Seong Woo
    Denisov, Artem O.
    Chen, Pengcheng
    Petta, Jason R.
    AIP ADVANCES, 2021, 11 (12)