Atrial fibrillation detection on reconstructed photoplethysmography signals collected from a smartwatch using a denoising autoencoder

被引:3
|
作者
Mohagheghian, Fahimeh [1 ]
Han, Dong [1 ]
Ghetia, Om [1 ]
Chen, Darren [1 ]
Peitzsch, Andrew [1 ]
Nishita, Nishat [2 ]
Ding, Eric Y. [3 ]
Otabil, Edith Mensah [3 ]
Noorishirazi, Kamran [3 ]
Hamel, Alexander [3 ]
Dickson, Emily L. [4 ]
Dimezza, Danielle [3 ]
Tran, Khanh-Van [3 ]
Mcmanus, David D. [3 ]
Chon, Ki H. [1 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[2] Univ Connecticut Hlth, Dept Publ Hlth Sci, Farmington, CT USA
[3] Univ Massachusetts, Div Cardiol, Med Sch, Worcester, MA USA
[4] Des Moines Univ, Coll Osteopath Med, Des Moines, IA USA
关键词
Photoplethysmography; Atrial fibrillation; Deep learning; Denoising; Autoencoder; STROKE;
D O I
10.1016/j.eswa.2023.121611
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Photoplethysmography (PPG) signals collected by wearables have been shown to be effective in accurate detection of atrial fibrillation (AF), provided that the data are devoid of motion and noise artifacts (MNA). Many studies have been previously conducted to detect AF arrhythmia using PPG data; however, the subjects were mostly in clinics or controlled settings with data collection lasting several minutes to at most several hours with minimal MNA. Our study, Pulsewatch, differs from previous AF studies in that PPG data from smartwatches prescribed to stroke survivors were continuously collected for two weeks in real-life conditions, which invariably included a significant amount of MNA. Our aim is to provide a framework for a novel use of a denoising autoencoder to reconstruct motion-artifact-removed PPG signals so that we can improve the AF detection per-formance and to increase the amount of analyzable data.We used more than 30,000 25-sec PPG segments from 129 subjects randomly selected from Pulsewatch and Stanford University's datasets. The training and testing datasets from these two databases came from smart-watches from different vendors with varying sampling frequencies and time duration of recordings in diverse and realistic settings. In this study, the highly corrupted PPG data were automatically detected and discarded, but those segments contaminated with low-to-moderate motion and noise artifacts (MNA) were subjected to a convolutional denoising autoencoder (CDA). To reconstruct the artifact-removed PPG segments, we proposed to employ two distinct CDA models for AF and non-AF data groups initially classified as AF or non-AF. Using the proposed approach, we significantly improved the performance of detecting occult AF. We achieved classifica-tion accuracy, sensitivity, and specificity of 91.02%, 91.54%, and 90.85%, respectively, for out-of-sample test data from both databases. By sanitizing data from low-to-moderate MNA, we were able to increase the usable data coverage by 21%.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis
    Gill, Simrat
    Bunting, Karina, V
    Sartini, Claudio
    Cardoso, Victor Roth
    Ghoreishi, Narges
    Uh, Hae-Won
    Williams, John A.
    Suzart-Woischnik, Kiliana
    Banerjee, Amitava
    Asselbergs, Folkert W.
    Eijkemans, Mjc
    Gkoutos, Georgios, V
    Kotecha, Dipak
    HEART, 2022, 108 (20) : 1600 - 1607
  • [32] Photoplethysmography based atrial fibrillation detection: a continually growing field
    Ding, Cheng
    Xiao, Ran
    Wang, Weijia
    Holdsworth, Elizabeth
    Hu, Xiao
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (04)
  • [33] Atrial Fibrillation Detection Utilizing Raw Photoplethysmography Waveform Data From a Fitness Tracker
    Yilmaz, Defne S.
    Liu, Jiaqi
    Gotlibovych, Igor
    Li, Jessie
    Benaron, David
    Marcus, Gregory M.
    CIRCULATION, 2018, 138
  • [34] Performance of an artificial intelligence algorithm to detect atrial fibrillation on a 24-hour continuous photoplethysmography recording using a smartwatch: ACURATE study
    Gruwez, H.
    Evens, S.
    Desteghe, L.
    Knaepen, L.
    Dreesen, P.
    Wouters, F.
    Deferm, S.
    Dauw, J.
    Smeets, C.
    Pison, L.
    Haemers, P.
    Heidbuchel, H.
    Vandervoort, P.
    EUROPEAN HEART JOURNAL, 2021, 42 : 489 - 489
  • [35] Usability of a smartwatch for atrial fibrillation detection in older adults after stroke
    Ding, Eric Y.
    Castanedaavila, Maira
    Tran, Khanh-Van
    Mehawej, Jordy
    Filippaios, Andreas
    Paul, Tenes
    Otabil, Edith Mensah
    Noorishirazi, Kamran
    Han, Dong
    Saczynski, Jane S.
    Barton, Bruce
    Mazor, Kathleen M.
    Chon, Ki
    McManus, David D.
    CARDIOVASCULAR DIGITAL HEALTH JOURNAL, 2022, 3 (03): : 126 - 135
  • [36] Automated atrial fibrillation classification based on denoising stacked autoencoder and optimized deep network
    Singh, Prateek
    Sharma, Ambalika
    Maiya, Shreesha
    EXPERT SYSTEMS WITH APPLICATIONS, 2023, 233
  • [37] Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data
    Eerikainen, Linda M.
    Bonomi, Alberto G.
    Schipper, Fons
    Dekker, Lukas R. C.
    de Morree, Helma M.
    Vullings, Rik
    Aarts, Ronald M.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (06) : 1610 - 1618
  • [38] Photoplethysmography-Based System for Atrial Fibrillation Detection During Hemodialysis
    Stankevicius, Dainius
    Petrenas, Andrius
    Solosenko, Andrius
    Grigutis, Mantas
    Januskevicius, Tomas
    Rimsevicius, Laurynas
    Marozas, Vaidotas
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 79 - 82
  • [39] A novel 1D generative adversarial network-based framework for atrial fibrillation detection using restored wrist photoplethysmography signals
    Sayem, Faizul Rakib
    Ahmed, Mosabber Uddin
    Alam, Saadia Binte
    Mahmud, Sakib
    Sheikh, Md. Mamun
    Alqahtani, Abdulrahman
    Faisal, Md Ahasan Atick
    Chowdhury, Muhammad E. H.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 101
  • [40] Atrial Fibrillation Detection Based on a Residual CNN Using BCG Signals
    Su, Qiushi
    Huang, Yanqi
    Wu, Xiaomei
    Zhang, Biyong
    Lu, Peilin
    Lyu, Tan
    ELECTRONICS, 2022, 11 (18)