Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach

被引:4
|
作者
Avram, George Mihai [1 ]
Prill, Robert [2 ,3 ]
Gurau, Cristian Dorin [1 ]
Georgeanu, Vlad [4 ]
Deleanu, Bogdan [5 ]
Russu, Octav [6 ]
Becker, Roland [2 ,3 ]
Predescu, Vlad [1 ]
机构
[1] Ponderas Acad Hosp, Orthopaed & Traumatol Dept, Bucharest 014142, Romania
[2] Univ Hosp Brandenburg Havel, Ctr Orthopaed & Traumatol, Brandenburg Med Sch Theodor Fontane, D-14770 Brandenburg Adh, Germany
[3] Brandenburg Med Sch Theodor Fontane, Fac Hlth Sci Brandenburg, D-14770 Brandenburg Adh, Germany
[4] Clin Emergency Hosp St Pantelimon, Orthopaed & Traumatol Dept, Bucharest, Romania
[5] Univ Med & Farm Timisoara, Orthopaed & Traumatol Dept, Timisoara, Romania
[6] Univ Med, Orthopaed & Traumatol Dept, Pharm Sci & Technol George Emil Palade, Targu Mures 540139, Romania
关键词
Hip arthroplasty; MAKO; Anterior-based muscle sparing; Acetabular cup; LEG LENGTH DISCREPANCY;
D O I
10.1007/s00264-023-05835-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe modified anterolateral approach (Rottinger) for total hip arthroplasty (THA) offers great advantages over conventional approaches, especially concerning early postoperative symptoms, which are mild and well tolerated by patients. Robotic-assisted implantation might facilitate rapid adoption of the modified anterolateral approach without exposing surgeons to risks encountered during the learning curve. This study posits that the use of robotic assistance in conjunction with the modified anterolateral approach for total hip arthroplasty (THA) can provide a substantial enhancement in the accuracy of cup placement in comparison to manual surgery.MethodsThirty-two robotic-assisted THAs met the inclusion criteria and were matched to 32 conventional cases. Acetabular cup inclination, anteversion, limb-length discrepancy, and acetabular offset were assessed using certified planning software by two independent observers using pre- and postoperative anterior-posterior radiographs. Data was analyzed for normal distribution. Chi(2) test was used to determine whether implanted acetabular cups that were within Lewinnek's safe zones were influenced by type of implantation. Effect size estimates and statistical power analysis were also performed to appreciate the appropriateness of the chosen sample size.ResultsRobotic-assisted implantation was found to significantly improve acetabular cup placement in terms of inclination (p < 0.001) but not anteversion (p = 0.783). Although mean postoperative limb-length discrepancy and mean acetabular offset did not differ between groups, a significantly smaller variance was found in the robotic-assisted group (p < 0.001) and (p = 0.04), respectively. There were no significant differences between the two groups in terms of consistently implanting the acetabular cup within the Lewinnek safe zones p = 0.641 for anteversion and p = 0.230 for inclination, respectively.ConclusionsOur results show that although robotic-assisted acetabular cup implantation performed through the modified anterolateral approach did not significantly differ from conventional implantation, it did offer increased accuracy in cup positioning, acetabular bone preservation, and limb-length restoration.
引用
收藏
页码:2265 / 2273
页数:9
相关论文
共 50 条
  • [41] Validation of navigation assisted cup placement in total hip arthroplasty
    Kumar, M. Ajith
    Shetty, M. Shantharam
    Kiran, Kanthi G.
    Kini, Abhishek R.
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (01) : 17 - 22
  • [42] 3D Printed Patient-Specific Acetabular Jig for Cup Placement in Total Hip Arthroplasty
    Mishra, Abhishek
    Verma, Tarun
    Rajkumar
    Agarwal, Gaurang
    Sharma, Amit
    Maini, Lalit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (02) : 174 - 180
  • [43] Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation
    Singh, Ashish
    Kumar, Purushotam
    Kalyan, Kanukuntla
    Gundalli, Akash Chandrashekar
    Mane, Sudhir Shankar
    Swarnkar, Himanshu
    Singh, Lavanya
    SICOT-J, 2024, 10
  • [44] Comparison of Postoperative Instability and Acetabular Cup Positioning in Robotic-Assisted Versus Traditional Total Hip Arthroplasty
    Shaw, Jonathan H.
    Rahman, Tahsin M.
    Wesemann, Luke D.
    Jiang, Charles Z.
    Lindsay-Rivera, Kevin G.
    Davis, Jason J.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (08): : S881 - S889
  • [45] Robotic-Assisted Total Hip Arthroplasty Through the Posterior Approach
    Schwabe, Maria T.
    Gibian, Joseph T.
    Bartosiak, Kimberly A.
    Bendich, Ilya
    Schneider, Andrew M.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2025, 15 (01):
  • [46] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [47] Novel Measure of Acetabular Cup Inclination and Anteversion During Total Hip Arthroplasty
    Walter, William L.
    Baker, Neri A.
    Marsden-Jones, Daniel
    Sadeghpour, Ameneh
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2022, 15 : 1 - 14
  • [48] Improving Acetabular Cup Orientation in Total Hip Arthroplasty by Using Smartphone Technology
    Meermans, Geert
    Kats, Jan Jaap
    JOURNAL OF ARTHROPLASTY, 2013, 28 (07): : 1246 - 1246
  • [49] Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
    Hasegawa, M
    Sudo, A
    Hirata, H
    Uchida, A
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05): : 658 - 661
  • [50] Influence of acetabular cup thickness on seating and primary stability in total hip arthroplasty
    Ruhr, Miriam
    Baetz, Johanna
    Pueschel, Klaus
    Morlock, Michael M.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (09) : 2139 - 2146