Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach

被引:4
|
作者
Avram, George Mihai [1 ]
Prill, Robert [2 ,3 ]
Gurau, Cristian Dorin [1 ]
Georgeanu, Vlad [4 ]
Deleanu, Bogdan [5 ]
Russu, Octav [6 ]
Becker, Roland [2 ,3 ]
Predescu, Vlad [1 ]
机构
[1] Ponderas Acad Hosp, Orthopaed & Traumatol Dept, Bucharest 014142, Romania
[2] Univ Hosp Brandenburg Havel, Ctr Orthopaed & Traumatol, Brandenburg Med Sch Theodor Fontane, D-14770 Brandenburg Adh, Germany
[3] Brandenburg Med Sch Theodor Fontane, Fac Hlth Sci Brandenburg, D-14770 Brandenburg Adh, Germany
[4] Clin Emergency Hosp St Pantelimon, Orthopaed & Traumatol Dept, Bucharest, Romania
[5] Univ Med & Farm Timisoara, Orthopaed & Traumatol Dept, Timisoara, Romania
[6] Univ Med, Orthopaed & Traumatol Dept, Pharm Sci & Technol George Emil Palade, Targu Mures 540139, Romania
关键词
Hip arthroplasty; MAKO; Anterior-based muscle sparing; Acetabular cup; LEG LENGTH DISCREPANCY;
D O I
10.1007/s00264-023-05835-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe modified anterolateral approach (Rottinger) for total hip arthroplasty (THA) offers great advantages over conventional approaches, especially concerning early postoperative symptoms, which are mild and well tolerated by patients. Robotic-assisted implantation might facilitate rapid adoption of the modified anterolateral approach without exposing surgeons to risks encountered during the learning curve. This study posits that the use of robotic assistance in conjunction with the modified anterolateral approach for total hip arthroplasty (THA) can provide a substantial enhancement in the accuracy of cup placement in comparison to manual surgery.MethodsThirty-two robotic-assisted THAs met the inclusion criteria and were matched to 32 conventional cases. Acetabular cup inclination, anteversion, limb-length discrepancy, and acetabular offset were assessed using certified planning software by two independent observers using pre- and postoperative anterior-posterior radiographs. Data was analyzed for normal distribution. Chi(2) test was used to determine whether implanted acetabular cups that were within Lewinnek's safe zones were influenced by type of implantation. Effect size estimates and statistical power analysis were also performed to appreciate the appropriateness of the chosen sample size.ResultsRobotic-assisted implantation was found to significantly improve acetabular cup placement in terms of inclination (p < 0.001) but not anteversion (p = 0.783). Although mean postoperative limb-length discrepancy and mean acetabular offset did not differ between groups, a significantly smaller variance was found in the robotic-assisted group (p < 0.001) and (p = 0.04), respectively. There were no significant differences between the two groups in terms of consistently implanting the acetabular cup within the Lewinnek safe zones p = 0.641 for anteversion and p = 0.230 for inclination, respectively.ConclusionsOur results show that although robotic-assisted acetabular cup implantation performed through the modified anterolateral approach did not significantly differ from conventional implantation, it did offer increased accuracy in cup positioning, acetabular bone preservation, and limb-length restoration.
引用
收藏
页码:2265 / 2273
页数:9
相关论文
共 50 条
  • [21] The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty
    Pearce, C. J.
    Sexton, S. A.
    Davies, D. C.
    Khaleel, A.
    HIP INTERNATIONAL, 2008, 18 (01) : 7 - 10
  • [22] The Optimal Skin Incision for Minimally Invasive Total Hip Arthroplasty Performed via the Anterolateral Approach
    Noble, Philip C.
    Pflueger, Gerald
    Junk-Jantsch, Sabine
    Thompson, Matthew T.
    Alexander, Jerry W.
    Mathis, Kenneth B.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 901 - 908
  • [23] Effect of acetabular cup position and orientation in cemented total hip arthroplasty
    Hirakawa, K
    Mitsugi, N
    Koshino, T
    Saito, T
    Hirasawa, Y
    Kubo, T
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 135 - 142
  • [24] Effects of acetabular abduction on cup wear rates in total hip arthroplasty
    Del Schutte, H
    Lipman, AJ
    Bannar, SM
    Livermore, JT
    Ilstrup, D
    Morrey, BF
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 621 - 626
  • [25] Oblong Acetabular Cup, Type TC, for Revision Total Hip Arthroplasty
    Trc, T.
    Stastny, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 506 - 511
  • [26] Dual mobility acetabular cup for total hip arthroplasty: use with caution
    Vahedi, Hamed
    Makhdom, Asim M.
    Parvizi, Javad
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (03) : 237 - 243
  • [27] Research Synthesis of Recommended Acetabular Cup Orientations for Total Hip Arthroplasty
    Harrison, Claire L.
    Thomson, Avril I.
    Cutts, Steven
    Rowe, Philip J.
    Riches, Philip E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 377 - 382
  • [28] Biomechanical Evaluation of Acetabular Cup Implantation in Cementless Total Hip Arthroplasty
    Margalit, Kate A.
    Hayashi, Kei
    Jackson, Josh
    Kim, Sun Young
    Garcia, Tanya C.
    Wiggans, K. Tomo
    Aiken, Sean
    Stover, Susan M.
    VETERINARY SURGERY, 2010, 39 (07) : 818 - 823
  • [29] Acetabular Cup Design Influences Deformational Response in Total Hip Arthroplasty
    Meding, John B.
    Small, Scott R.
    Jones, Mary E.
    Berend, Michael E.
    Ritter, Merrill A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 403 - 409
  • [30] ACETABULAR CUP-SITING DEVICE FOR TOTAL HIP-ARTHROPLASTY
    DOYLE, J
    MURRAY, P
    MAHONY, PO
    FARMER, M
    HOOPER, AC
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1989, 108 (05) : 317 - 321