Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach

被引:4
|
作者
Avram, George Mihai [1 ]
Prill, Robert [2 ,3 ]
Gurau, Cristian Dorin [1 ]
Georgeanu, Vlad [4 ]
Deleanu, Bogdan [5 ]
Russu, Octav [6 ]
Becker, Roland [2 ,3 ]
Predescu, Vlad [1 ]
机构
[1] Ponderas Acad Hosp, Orthopaed & Traumatol Dept, Bucharest 014142, Romania
[2] Univ Hosp Brandenburg Havel, Ctr Orthopaed & Traumatol, Brandenburg Med Sch Theodor Fontane, D-14770 Brandenburg Adh, Germany
[3] Brandenburg Med Sch Theodor Fontane, Fac Hlth Sci Brandenburg, D-14770 Brandenburg Adh, Germany
[4] Clin Emergency Hosp St Pantelimon, Orthopaed & Traumatol Dept, Bucharest, Romania
[5] Univ Med & Farm Timisoara, Orthopaed & Traumatol Dept, Timisoara, Romania
[6] Univ Med, Orthopaed & Traumatol Dept, Pharm Sci & Technol George Emil Palade, Targu Mures 540139, Romania
关键词
Hip arthroplasty; MAKO; Anterior-based muscle sparing; Acetabular cup; LEG LENGTH DISCREPANCY;
D O I
10.1007/s00264-023-05835-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe modified anterolateral approach (Rottinger) for total hip arthroplasty (THA) offers great advantages over conventional approaches, especially concerning early postoperative symptoms, which are mild and well tolerated by patients. Robotic-assisted implantation might facilitate rapid adoption of the modified anterolateral approach without exposing surgeons to risks encountered during the learning curve. This study posits that the use of robotic assistance in conjunction with the modified anterolateral approach for total hip arthroplasty (THA) can provide a substantial enhancement in the accuracy of cup placement in comparison to manual surgery.MethodsThirty-two robotic-assisted THAs met the inclusion criteria and were matched to 32 conventional cases. Acetabular cup inclination, anteversion, limb-length discrepancy, and acetabular offset were assessed using certified planning software by two independent observers using pre- and postoperative anterior-posterior radiographs. Data was analyzed for normal distribution. Chi(2) test was used to determine whether implanted acetabular cups that were within Lewinnek's safe zones were influenced by type of implantation. Effect size estimates and statistical power analysis were also performed to appreciate the appropriateness of the chosen sample size.ResultsRobotic-assisted implantation was found to significantly improve acetabular cup placement in terms of inclination (p < 0.001) but not anteversion (p = 0.783). Although mean postoperative limb-length discrepancy and mean acetabular offset did not differ between groups, a significantly smaller variance was found in the robotic-assisted group (p < 0.001) and (p = 0.04), respectively. There were no significant differences between the two groups in terms of consistently implanting the acetabular cup within the Lewinnek safe zones p = 0.641 for anteversion and p = 0.230 for inclination, respectively.ConclusionsOur results show that although robotic-assisted acetabular cup implantation performed through the modified anterolateral approach did not significantly differ from conventional implantation, it did offer increased accuracy in cup positioning, acetabular bone preservation, and limb-length restoration.
引用
收藏
页码:2265 / 2273
页数:9
相关论文
共 50 条
  • [1] Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach
    George Mihai Avram
    Robert Prill
    Cristian Dorin Gurau
    Vlad Georgeanu
    Bogdan Deleanu
    Octav Russu
    Roland Becker
    Vlad Predescu
    International Orthopaedics, 2023, 47 : 2265 - 2273
  • [2] Precision of acetabular cup placement in robotic integrated total hip arthroplasty
    Elson, Leah
    Dounchis, Jon
    Illgen, Richard
    Marchand, Robert C.
    Padgett, Douglas E.
    Bragdon, Charles R.
    Malchau, Henrik
    HIP INTERNATIONAL, 2015, 25 (06) : 531 - 536
  • [3] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Cho, Eiji
    Hisatome, Takashi
    Oda, Shuhei
    Fujimaki, Hirohisa
    Nakanishi, Kazuyoshi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [4] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Eiji Cho
    Takashi Hisatome
    Shuhei Oda
    Hirohisa Fujimaki
    Kazuyoshi Nakanishi
    Journal of Orthopaedic Surgery and Research, 17
  • [5] Modified anterolateral approach in minimally invasive total hip arthroplasty
    Tsai, Shang-Wen
    Chen, Cheng-Fong
    Wu, Po-Kuei
    Chen, Tain-Hsiung
    Liu, Chien-Lin
    Chen, Wei-Ming
    HIP INTERNATIONAL, 2015, 25 (03) : 245 - 250
  • [6] Non invasive modified anterolateral approach in total hip arthroplasty
    Aebi, J.
    Giraud, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (06) : 675 - 680
  • [7] Acetabular cup size trends in total hip arthroplasty
    Mckenna, Daniel Patrick
    Price, Alex
    Mcaleese, Timothy
    Dahly, Darren
    Mckenna, Paul
    Cleary, May
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (01): : 39 - 44
  • [8] Should the acetabular cup be medialised in total hip arthroplasty?
    Bonnin, Michel P.
    Archbold, Pooler H. A.
    Basiglini, Luca
    Selmi, Tarik A.
    Beverland, David E.
    HIP INTERNATIONAL, 2011, 21 (04) : 428 - 435
  • [9] ACETABULAR CUP WEAR IN TOTAL HIP-ARTHROPLASTY
    RIMNAC, CM
    WILSON, PD
    FUCHS, MD
    WRIGHT, TM
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 631 - 636
  • [10] Cementless total hip arthroplasty with a threaded acetabular cup
    J. Fernández-González
    R. Canosa Sevillano
    C. García-Araujo
    International Orthopaedics, 1997, 21 : 327 - 331