DFT and electrochemical determination of Hg2+ and Pb2+ in water using polyaniline-quinoxaline composite modified GCE electrode

被引:4
|
作者
Maheshwaran, Muniyasamy [1 ]
Kumar, Konda Kannan Satheesh [1 ]
机构
[1] Gandhigram Rural Inst Deemed Univ, Dept Chem, Gandhigram 624302, TN, India
关键词
Polyaniline-quinoxaline; Composite; DFT study; Electrochemical sensor; Heavy metal ions; Electrolytic system; GRAPHENE OXIDE; ION; PERFORMANCE; SENSOR; CU2+; CD2+; NANOCOMPOSITE;
D O I
10.1016/j.molliq.2024.124317
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, we designed and synthesized a new class of donor-acceptor conjugated polymers containing the polyaniline-quinoxaline [Acenaptho [1, 2 -b] quinoxalin-9-amine] (PAni-QUA) composite, and we subsequently utilized it as an electrochemical sensor to detect Hg2+ and Pb2+ ions with good selectivity and sensitivity. Energy dispersive X-ray analysis spectroscopy (EDAX), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and UV-Vis spectroscopy (UV-Vis) were employed to analyze the structural and morphological characteristics of the resulting composite. The electrochemical characteristics of the electrode modifiers were analyzed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Several sensitivity-influencing factors, including chemical and electrochemical parameters like pH and the impact of the supporting electrolyte medium, were also identified to improve the efficiency of the developed sensor. In the presence of different hazardous metal ion species, the interference ability of the proposed sensor was also examined. They were also used to conduct individual and simultaneous sensing studies of various metal ions in different supportive electrolyte media utilizing the differential pulse voltammetry technique (DPV). The PAni-QUA composite modified GCE sensor shows remarkable selectivity and sensitivity towards Hg2+ and Pb2+ ions over the other heavy metal ions in 1 to 20 mu M ranges, respectively. The detection limits (3 sigma/m) were 1.28 nM and 5.91 nM for Hg2+ and Pb2+ ions. Density Functional Theory (DFT) was used in the present study to accomplish the adsorption mechanism of the suggested sensors. The DFT calculation demonstrated that the PAniQUA composite was formed with a lower band gap energy than QUA and DD PAni. These results showed that the suggested sensor (PAni-QUA) had the lowest detection limit in the acetate buffer medium compared to the specified electrolyte media. Based on these findings, it is possible to use this technology to identify harmful metal ions (Hg2+ and Pb2+) with high sensitivity in real water samples.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Voltammetric Determination of Hg2+, Zn2+, and Pb2+ Ions Using a PEDOT/NTA-Modified Electrode
    Alshawi, Jasim M. S.
    Mohammed, Mohammed Q.
    Alesary, Hasan F.
    Ismail, Hani K.
    Barton, Stephen
    ACS OMEGA, 2022, 7 (23): : 20405 - 20419
  • [2] Experimental and DFT Investigation on the Ultra Selective Determination of Hg2+ Ion in Water Implementing a PAni-RR5B Composite Modified GCE Electrode
    Muniyasamy, Maheshwaran
    Varatharaj, Rajapandian
    Kannan, Satheesh Kumar Konda
    JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2024,
  • [3] Electrochemical determination of Pb2+ using a carbon nanotube/Nafion composite film-modified electrode
    Sun, Dong
    Sun, Zhongmin
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (09) : 1223 - 1227
  • [4] Electrochemical determination of Pb2+ using a carbon nanotube/Nafion composite film-modified electrode
    Dong Sun
    Zhongmin Sun
    Journal of Applied Electrochemistry, 2008, 38 : 1223 - 1227
  • [5] An electrochemical voltammetric response of Hg2+and Pb2+ions using polyaniline-benzothiazole composite modified GCE electrode: Synthesis, characterization and quantum chemical calculation
    Maheshwaran, Muniyasamy
    Sivaraman, Gandhi
    Kumar, Konda Kannan Satheesh
    MICROCHEMICAL JOURNAL, 2024, 197
  • [6] Co@IRMOF-9/GCE sensor for rapid electrochemical identification of trace Hg2+, Pb2+ and NO2- in solutions
    Zhu, Ding
    Die, Yang
    Tian, Si-Yu
    Yao, Mu-Lan
    Liu, Si-Mian
    Hou, Xiang-Yang
    Long, Tang
    Yue, Er-Lin
    Wang, Ji-Jiang
    Xiao, Wang
    JOURNAL OF SOLID STATE CHEMISTRY, 2024, 338
  • [7] Spent Coffee Bioelastomeric Composite Foams for the Removal of Pb2+ and Hg2+ from Water
    Chavan, Asmita A.
    Pinto, Javier
    Liakos, Ioannis
    Bayer, Ilker S.
    Lauciello, Simone
    Athanassiou, Athanassia
    Fragouli, Despina
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2016, 4 (10): : 5495 - 5502
  • [8] Electrochemiluminescence aptasensor for multiple determination of Hg2+ and Pb2+ ions by using the MIL-53(Al)@CdTe-PEI modified electrode
    Feng, Defen
    Li, Penghui
    Tan, Xuecai
    Yeyu, Wu
    Wei, Fucun
    Du, Fangkai
    Ai, Chenhao
    Luo, Yanni
    Chen, Quanyou
    Han, Heyou
    ANALYTICA CHIMICA ACTA, 2020, 1100 : 232 - 239
  • [9] ZnS Nanoparticle Gels for Remediation of Pb2+ and Hg2+ Polluted Water
    Pala, Irina R.
    Brock, Stephanie L.
    ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (04) : 2160 - 2167
  • [10] Spectrofluorimetric determination of Hg2+ and Pb2+ using acetylcholinesterase (AChE)-based formation of silver nanoparticles
    Kumar, D. Nanda
    Roy, Jaydeep
    Alex, S. A.
    Chandrasekaran, N.
    Mukherjee, A.
    RSC ADVANCES, 2016, 6 (25) : 21261 - 21270