Voltammetric Determination of Hg2+, Zn2+, and Pb2+ Ions Using a PEDOT/NTA-Modified Electrode

被引:40
|
作者
Alshawi, Jasim M. S. [1 ]
Mohammed, Mohammed Q. [1 ]
Alesary, Hasan F. [4 ]
Ismail, Hani K. [2 ]
Barton, Stephen [3 ]
机构
[1] Univ Basrah, Coll Educ Pure Sci, Dept Chem, Basrah 61001, Iraq
[2] Koya Univ, Fac Sci & Hlth, Dept Chem, KOY45, Koya, Kurdistan Regio, Iraq
[3] Kingston Univ London, Sch Life Sci Pharm & Chem, Kingston Upon Thames KT1 1LQ, Surrey, England
[4] Univ Kerbala, Coll Sci, Dept Chem, Karbala 56001, Iraq
来源
ACS OMEGA | 2022年 / 7卷 / 23期
关键词
HEAVY-METAL IONS; ELECTROCHEMICAL SENSOR; LEAD IONS; RAPID REMOVAL; CADMIUM; COMPOSITE; COPPER; DESIGN; FILMS; WATER;
D O I
10.1021/acsomega.2c02682
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemical sensor for determining trace levels of Hg2+, Pb2+, and Zn2+ ions in water using square wave voltammetry (SWV) is reported. The sensor is based on a platinum electrode (Pt) modified by poly(3,4-ethylenedioxythiophene) and N alpha,N alpha-bis-(carboxymethyl)-L-lysine hydrate (NTA lysine) PEDOT/NTA. The modified electrode surface (PEDOT/NTA) was prepared via the introduction of the lysine-NTA group to a PEDOT/N-hydroxyphthalimide NHP electrode. The (PEDOT/NTA) was characterized via cyclic voltammetry (CV), Fourier transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM). The effects of scan rates on the electrochemical properties of the polymer electrode were also investigated. The electrochemical results were used to estimate the coverage of the electrode polymer surface and its electrostability in background electrolyte solutions. Several analytical parameters, such as polymer film thickness, metal deposition time, and pH of the electrolyte, were examined. Linear responses to Hg2+, Pb2+, and Zn2+ ions in the concentration range of 5-100 mu g L-1 were obtained. The limits of detection (LODs) for the determination of Hg2+, Pb2+, and Zn2+ ions were 1.73, 2.33, and 1.99 mu g L-1, respectively. These promising results revealed that modified PEDOT/NTA films might well represent an important addition to existing electrochemical sensor technologies.
引用
收藏
页码:20405 / 20419
页数:15
相关论文
共 50 条
  • [1] On the interaction of N-acetylcysteine with Pb2+, Zn2+, Cd2+ and Hg2+
    Cardiano, Paola
    Foti, Claudia
    Giuffre, Ottavia
    JOURNAL OF MOLECULAR LIQUIDS, 2016, 223 : 360 - 367
  • [2] Simultaneous determination of Cu2+, Zn2+, Cd2+, Hg2+ and Pb2+ by using second-derivative spectrophotometry method
    Han, Yanyan
    Li, Yan
    Si, Wei
    Wei, Dong
    Yao, Zhenxing
    Zheng, Xianpeng
    Du, Bin
    Wei, Qin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 79 (05) : 1546 - 1551
  • [3] Electrochemiluminescence aptasensor for multiple determination of Hg2+ and Pb2+ ions by using the MIL-53(Al)@CdTe-PEI modified electrode
    Feng, Defen
    Li, Penghui
    Tan, Xuecai
    Yeyu, Wu
    Wei, Fucun
    Du, Fangkai
    Ai, Chenhao
    Luo, Yanni
    Chen, Quanyou
    Han, Heyou
    ANALYTICA CHIMICA ACTA, 2020, 1100 : 232 - 239
  • [4] DFT and electrochemical determination of Hg2+ and Pb2+ in water using polyaniline-quinoxaline composite modified GCE electrode
    Maheshwaran, Muniyasamy
    Kumar, Konda Kannan Satheesh
    JOURNAL OF MOLECULAR LIQUIDS, 2024, 398
  • [5] Simultaneous electrochemical sensing of heavy metal ions (Zn2+, Cd2+, Pb2+, and Hg2+) in food samples using a covalent organic framework/ carbon black modified glassy carbon electrode
    Karazan, Zahra Mirzaei
    Roushani, Mahmoud
    Hoseini, S. Jafar
    FOOD CHEMISTRY, 2024, 442
  • [6] Simultaneous electrochemical sensing of heavy metal ions (Zn2+, Cd2+, Pb2+, and Hg2+) in food samples using a covalent organic framework/carbon black modified glassy carbon electrode
    Department of Chemistry, Faculty of Sciences, Ilam University, Ilam
    P. O. BOX. 69315-516, Iran
    不详
    7194684795, Iran
    Food Chem.,
  • [7] Effect of the Zn2+ and Hg2+ Ions on the Structure of Liquid Water
    Migliorati, Valentina
    Mancini, Giordano
    Chillemi, Giovanni
    Zitolo, Andrea
    D'Angelo, Paola
    JOURNAL OF PHYSICAL CHEMISTRY A, 2011, 115 (18): : 4798 - 4803
  • [8] Polypyridinic ligand coordination to Zn2+ and Hg2+ metal ions
    Andrea Melchior
    Cristian Grazioli
    Claudio Tavagnacco
    Marilena Tolazzi
    Journal of Thermal Analysis and Calorimetry, 2015, 119 : 1267 - 1272
  • [9] Polypyridinic ligand coordination to Zn2+ and Hg2+ metal ions
    Melchior, Andrea
    Grazioli, Cristian
    Tavagnacco, Claudio
    Tolazzi, Marilena
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 119 (02) : 1267 - 1272
  • [10] Simultaneous voltammetric sensing of Zn2+, Cd2+, and Pb2+ using an electrodeposited Bi-Sb nanocomposite modified carbon paste electrode
    Shalaby, E. A.
    Beltagi, A. M.
    Hathoot, A. A.
    Azzem, M. Abdel
    RSC ADVANCES, 2023, 13 (11) : 7118 - 7128