DFT and electrochemical determination of Hg2+ and Pb2+ in water using polyaniline-quinoxaline composite modified GCE electrode

被引:4
|
作者
Maheshwaran, Muniyasamy [1 ]
Kumar, Konda Kannan Satheesh [1 ]
机构
[1] Gandhigram Rural Inst Deemed Univ, Dept Chem, Gandhigram 624302, TN, India
关键词
Polyaniline-quinoxaline; Composite; DFT study; Electrochemical sensor; Heavy metal ions; Electrolytic system; GRAPHENE OXIDE; ION; PERFORMANCE; SENSOR; CU2+; CD2+; NANOCOMPOSITE;
D O I
10.1016/j.molliq.2024.124317
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, we designed and synthesized a new class of donor-acceptor conjugated polymers containing the polyaniline-quinoxaline [Acenaptho [1, 2 -b] quinoxalin-9-amine] (PAni-QUA) composite, and we subsequently utilized it as an electrochemical sensor to detect Hg2+ and Pb2+ ions with good selectivity and sensitivity. Energy dispersive X-ray analysis spectroscopy (EDAX), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and UV-Vis spectroscopy (UV-Vis) were employed to analyze the structural and morphological characteristics of the resulting composite. The electrochemical characteristics of the electrode modifiers were analyzed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Several sensitivity-influencing factors, including chemical and electrochemical parameters like pH and the impact of the supporting electrolyte medium, were also identified to improve the efficiency of the developed sensor. In the presence of different hazardous metal ion species, the interference ability of the proposed sensor was also examined. They were also used to conduct individual and simultaneous sensing studies of various metal ions in different supportive electrolyte media utilizing the differential pulse voltammetry technique (DPV). The PAni-QUA composite modified GCE sensor shows remarkable selectivity and sensitivity towards Hg2+ and Pb2+ ions over the other heavy metal ions in 1 to 20 mu M ranges, respectively. The detection limits (3 sigma/m) were 1.28 nM and 5.91 nM for Hg2+ and Pb2+ ions. Density Functional Theory (DFT) was used in the present study to accomplish the adsorption mechanism of the suggested sensors. The DFT calculation demonstrated that the PAniQUA composite was formed with a lower band gap energy than QUA and DD PAni. These results showed that the suggested sensor (PAni-QUA) had the lowest detection limit in the acetate buffer medium compared to the specified electrolyte media. Based on these findings, it is possible to use this technology to identify harmful metal ions (Hg2+ and Pb2+) with high sensitivity in real water samples.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Green synthesis of copper oxide nanoparticles using Ficus elastica extract for the electrochemical simultaneous detection of Cd2+, Pb2+, and Hg2+
    Ben Ali, Djihane Slimane
    Krid, Ferial
    Nacef, Mouna
    Boussaha, El Hadi
    Chelaghmia, Mohamed Lyamine
    Tabet, Habiba
    Selaimia, Radia
    Atamnia, Amira
    Affoune, Abed Mohamed
    RSC ADVANCES, 2023, 13 (27) : 18734 - 18747
  • [42] Electrochemical sensor based on a thin film of organokaolinite material modified glassy carbon electrode (GCE) and application to the simultaneous sensitive detection of Pb2+ and Cu2+ ions in contaminated water
    Ngassa, Guy Bertrand Piegang
    Tchoffo, Rodrigue
    Boutianala, Michele
    Nintedem, Laura
    Tchonguang, Sorelle Aurnella Yameni
    Fogang, Hyane Fredolin Leuga
    Tonle, Ignas Kenfack
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (10) : 2339 - 2359
  • [43] Efficient Removal of Pb2+, Cd2+, and Hg2+ from Wastewater Using Advanced Graphene Oxide-Zirconium Hybrid Composite
    Patel, Meet
    Lanakapati, Henilkumar
    Maheria, Kalpana
    ACS APPLIED ENGINEERING MATERIALS, 2024, 2 (06): : 1542 - 1560
  • [44] Electrochemical study of a metallothionein modified gold disk electrode and its action on Hg2+ cations
    Ju, HX
    Leech, D
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 484 (02) : 150 - 156
  • [45] Simultaneous determination of Cu2+, Zn2+, Cd2+, Hg2+ and Pb2+ by using second-derivative spectrophotometry method
    Han, Yanyan
    Li, Yan
    Si, Wei
    Wei, Dong
    Yao, Zhenxing
    Zheng, Xianpeng
    Du, Bin
    Wei, Qin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 79 (05) : 1546 - 1551
  • [46] Preparation of Carboxy-Functionalized Covalent Organic Framework for Efficient Removal of Hg2+ and Pb2+ from Water
    Lu, Xiao-Fan
    Ji, Wen-Hua
    Yuan, Lin
    Yu, Shui
    Guo, Dian-Shun
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (38) : 17660 - 17667
  • [47] A novel gallium oxide nanoparticles-based sensor for the simultaneous electrochemical detection of Pb2+, Cd2+ and Hg2+ ions in real water samples
    Abd El-Fatah, Gehad
    Magar, Hend S.
    Hassan, Rabeay Y. A.
    Mahmoud, Rehab
    Farghali, Ahmed A.
    Hassouna, Mohamed E. M.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [48] A novel gallium oxide nanoparticles-based sensor for the simultaneous electrochemical detection of Pb2+, Cd2+ and Hg2+ ions in real water samples
    Gehad Abd El-Fatah
    Hend S. Magar
    Rabeay Y. A. Hassan
    Rehab Mahmoud
    Ahmed A. Farghali
    Mohamed E. M. Hassouna
    Scientific Reports, 12
  • [49] A Microfluidic Chip Integrated With a Carbon Nanotube-Polydimethylsiloxane Electrode Array for Simultaneous Detection of Cd2+, Pb2+, and Hg2+
    Zhang, Wenhong
    Han, Junlei
    Xu, Zhipeng
    Chen, Jun
    Su, Weiguang
    Zhou, Xiangxiang
    Wang, Jing
    Wang, Li
    IEEE SENSORS JOURNAL, 2023, 23 (18) : 20984 - 20991
  • [50] Simultaneous Determination of Pb2+ and Cd2+ in Isatis Root by a Bismuth/ Graphene Composite Film Modified Glassy Carbon Electrode
    Wu Min
    Li Hui
    Wang Xue
    Wang Qing-Jiang
    He Pin-Gang
    Fang Yu-Zhi