Less Is More for Non-Dislocated Femoral Neck Fractures: Similar Results for Two versus Three Cannulated Hip Screws

被引:0
|
作者
Schutte, Hilde [1 ]
Hulshof, Lorenzo [1 ]
van Olden, Ger [1 ]
van Koperen, Paul [1 ]
Timmers, Tim [1 ]
Kluijfhout, Wouter [1 ]
机构
[1] Meander Med Ctr, Dept Trauma Surg, NL-3813 TZ Amersfoort, Netherlands
来源
SURGERIES | 2023年 / 4卷 / 04期
关键词
hip fractures; femoral neck fractures; fracture fixation; internal; postoperative complications; reoperation; FIXATION;
D O I
10.3390/surgeries4040048
中图分类号
R61 [外科手术学];
学科分类号
摘要
Cannulated hip screws (CHS) can be used for the minimally invasive fixation of non-dislocated femoral neck fractures. Usually, three screws are inserted. This study aims to determine whether fixation by two CHS leads to similar results as fixation by three CHS. Since January 2019, all patients with an indication for internal fixation by CHS were treated with two CHS and followed prospectively. Results were compared to an equal-sized control group of patients who underwent fixation by three CHS (before 2019). The primary outcome was reoperation, while the secondary outcome was screw dislocation. Since January 2019, 50 patients were treated by two CHS. Of these, 14 patients (28%) underwent reoperation versus 13 patients (26%) in the control group (p = 1.000). Reoperations included screw replacement, hemiarthroplasty, and total hip prosthesis. Three major reasons for reoperation were pain due to osteosynthesis material (n = 15), coxarthrosis (n = 4), and screw cut out (n = 3). Six weeks postoperative X-rays showed a screw dislocation of 2 mm for the two CHS group and 1 mm for the three CHS group (p = 0.330). Clinical outcomes were very similar between the groups. The overall results were good; however, the reoperation rate varied from 26 to 28%. The majority of reoperations were screw replacements. Screw dislocation seems to be more prominent in patients treated with two screws (2 mm versus 1 mm). Fixation by two cannulated hip screws is an acceptable treatment method for non-dislocated femoral neck fractures, and the insertion of a third screw does not lead to superior clinical results.
引用
收藏
页码:493 / 502
页数:10
相关论文
共 50 条
  • [1] Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?
    Krastman, Patrick
    van den Bent, Rob P.
    Krijnen, Pieta
    Schipper, Inger B.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (05) : 297 - 303
  • [2] Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?
    Patrick Krastman
    Rob P. van den Bent
    Pieta Krijnen
    Inger B. Schipper
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 297 - 303
  • [3] The Targon Femoral Neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip
    Griffin, X. L.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 652 - 657
  • [4] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Lang Li
    Xue Zhao
    Xiaodong Yang
    Xueyang Tang
    Ming Liu
    Journal of Orthopaedic Surgery and Research, 15
  • [5] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Li, Lang
    Zhao, Xue
    Yang, Xiaodong
    Tang, Xueyang
    Liu, Ming
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [6] Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study
    Yan, Shuang G.
    Cui, Yiliang
    Li, Di
    Liu, Fanxiao
    Hua, Xingyi
    Schmidutz, Florian
    JOURNAL OF INVESTIGATIVE SURGERY, 2023, 36 (01)
  • [7] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69
  • [8] Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures
    Zhou, Xiao-Qiang
    Li, Zhi-Qiang
    Xu, Ren-Jie
    She, Yuan-Shi
    Zhang, Xiang-Xin
    Chen, Guang-Xiang
    Yu, Xiao
    ORTHOPAEDIC SURGERY, 2021, 13 (06) : 1802 - 1809
  • [9] Cannulated screws versus hemiarthroplasty for displaced intracapsular femoral neck fractures in demented patients
    van Dortmont, LMC
    Douw, CM
    van Breukelen, AMA
    Laurens, DR
    Mulder, PGH
    Wereldsma, JCJ
    van Vugt, AB
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2000, 89 (02) : 132 - 137
  • [10] Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures A meta-analysis
    Zhang, Lei Lei
    Zhang, Ying
    Ma, Xianghao
    Liu, Youwen
    ORTHOPADE, 2017, 46 (11): : 954 - 962