Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?

被引:24
|
作者
Krastman, Patrick
van den Bent, Rob P.
Krijnen, Pieta
Schipper, Inger B.
机构
[1] Univ Rotterdam Hosp, Erasmus Med Ctr, Dept Gen Surg & Traumatol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
关键词
hip fracture; garden; Pauwels; osteosynthesis; minimal invasive fixation; cannulated screw; reintervention; hemi-arthroplasty; functional outcome;
D O I
10.1007/s00402-006-0143-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Undisplaced intracapsular fractures are predominantly treated with a minimally invasive fixation technique, whereas the standard treatment for displaced intracapsular fractures is still a subject of discussion. The purpose of this study was to identify the determinants influencing the outcome of intracapsular femoral neck fractures, treated with two cannulated hip screws. Patients and methods: From January 1998 through December 2002 data of all consecutive patients with an intracapsular femoral fracture, treated with two cannulated screws, were documented. Consolidation was chosen as the primary endpoint, mortality and a reoperation for replacement of osteosynthesis were defined secondary endpoints. Results: One hundred and twelve patients were included in the study. Fifty six percent of the intracapsular fractures healed within 1 year. Consolidation was accomplished in 95% of the stable fractures. Consolidation rates were negatively influenced by unstable fractures and inadequate anatomical reduction. The position of the screws did not influence consolidation rates. Reintervention rates were related to the number of local complications and the fracture type. Conclusion: In conclusion, the results of this study show that in case of operative treatment, undisplaced femoral neck fractures can be adequately fixated by two cannulated hip screws. Unstable, anatomically reduced femoral neck fracture (Garden III/IV) may be treated with a more stable implant (e.g. DHS) to avoid redisplacement. If adequate reduction cannot be achieved, endoprosthetic replacement is recommended.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [1] Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?
    Patrick Krastman
    Rob P. van den Bent
    Pieta Krijnen
    Inger B. Schipper
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 297 - 303
  • [2] Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis
    Xia, Yutong
    Zhang, Wendong
    Zhang, Zhen
    Wang, Jingcheng
    Yan, Lianqi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [3] Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis
    Yutong Xia
    Wendong Zhang
    Zhen Zhang
    Jingcheng Wang
    Lianqi Yan
    Journal of Orthopaedic Surgery and Research, 16
  • [4] Proximal Femoral Locking Plate With Cannulated Screws for the Treatment of Femoral Neck Fractures
    Lin, Dasheng
    Lian, Kejian
    Ding, Zhenqi
    Zhai, Wenliang
    Hong, Jiayuan
    ORTHOPEDICS, 2012, 35 (01) : E1 - E5
  • [5] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [6] The Targon Femoral Neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip
    Griffin, X. L.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 652 - 657
  • [7] Surgical treatment with cannulated screws for pediatric femoral neck fractures: A case series
    Pavone, Vito
    Testa, Gianluca
    Riccioli, Maria
    Di Stefano, Antonio
    Condorelli, Giuseppe
    Sessa, Giuseppe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : S40 - S44
  • [8] Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures A meta-analysis
    Zhang, Lei Lei
    Zhang, Ying
    Ma, Xianghao
    Liu, Youwen
    ORTHOPADE, 2017, 46 (11): : 954 - 962
  • [9] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Lang Li
    Xue Zhao
    Xiaodong Yang
    Xueyang Tang
    Ming Liu
    Journal of Orthopaedic Surgery and Research, 15
  • [10] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Li, Lang
    Zhao, Xue
    Yang, Xiaodong
    Tang, Xueyang
    Liu, Ming
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)