Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?

被引:24
|
作者
Krastman, Patrick
van den Bent, Rob P.
Krijnen, Pieta
Schipper, Inger B.
机构
[1] Univ Rotterdam Hosp, Erasmus Med Ctr, Dept Gen Surg & Traumatol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
关键词
hip fracture; garden; Pauwels; osteosynthesis; minimal invasive fixation; cannulated screw; reintervention; hemi-arthroplasty; functional outcome;
D O I
10.1007/s00402-006-0143-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Undisplaced intracapsular fractures are predominantly treated with a minimally invasive fixation technique, whereas the standard treatment for displaced intracapsular fractures is still a subject of discussion. The purpose of this study was to identify the determinants influencing the outcome of intracapsular femoral neck fractures, treated with two cannulated hip screws. Patients and methods: From January 1998 through December 2002 data of all consecutive patients with an intracapsular femoral fracture, treated with two cannulated screws, were documented. Consolidation was chosen as the primary endpoint, mortality and a reoperation for replacement of osteosynthesis were defined secondary endpoints. Results: One hundred and twelve patients were included in the study. Fifty six percent of the intracapsular fractures healed within 1 year. Consolidation was accomplished in 95% of the stable fractures. Consolidation rates were negatively influenced by unstable fractures and inadequate anatomical reduction. The position of the screws did not influence consolidation rates. Reintervention rates were related to the number of local complications and the fracture type. Conclusion: In conclusion, the results of this study show that in case of operative treatment, undisplaced femoral neck fractures can be adequately fixated by two cannulated hip screws. Unstable, anatomically reduced femoral neck fracture (Garden III/IV) may be treated with a more stable implant (e.g. DHS) to avoid redisplacement. If adequate reduction cannot be achieved, endoprosthetic replacement is recommended.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [31] Treatment of Delbet II/III Pediatric Femoral Neck Fractures With Proximal Femoral Locking Plate Versus Cannulated Screws
    Haider, Shamrez
    Harris, Timothy J.
    Turner, Alexander C.
    Podeszwa, David A.
    Hartman, Courtney A.
    Morris, William Z.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (04) : 213 - 220
  • [32] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Huang, Shaolong
    Zhang, Yazhong
    Zhang, Xu
    Zhou, Chengqiang
    Li, Wenbo
    Wang, Yunqing
    Wang, Bin
    Zhu, Ziqiang
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [33] Cannulated hip screws for the prophylactical fixation of femoral neck fractures Garden type I or II. An adequate treatment for patients 65+?
    Mumme, Marcus
    Pretto, Manuela
    Muri-John, Vanessa
    Suhm, Norbert
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 3S - 3S
  • [34] Cannulated screws versus hemiarthroplasty for displaced intracapsular femoral neck fractures in demented patients
    van Dortmont, LMC
    Douw, CM
    van Breukelen, AMA
    Laurens, DR
    Mulder, PGH
    Wereldsma, JCJ
    van Vugt, AB
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2000, 89 (02) : 132 - 137
  • [35] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Shaolong Huang
    Yazhong Zhang
    Xu Zhang
    Chengqiang Zhou
    Wenbo Li
    Yunqing Wang
    Bin Wang
    Ziqiang Zhu
    BioMedical Engineering OnLine, 22
  • [36] Dynamic Hip and Cannulated Screws in Fixation of Adults Femoral Neck Fracture: A Comparative Study
    Al-Kelabi, Adnan Essa
    Mahmoud, Mustafa Shakir
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (03): : 135 - 142
  • [37] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [38] Titanium alloy cannulated screws and biodegrade ceramic nails for treatment of femoral neck fractures: A finite element analysis
    Liu, Yang
    Ren, Zhiyuan
    Shao, Huifeng
    Wang, Xueding
    Ma, Yongsheng
    Song, Wenjie
    Wu, Xiaogang
    Zhang, Xiangyu
    Li, Pengcui
    He, Yong
    Wei, Xiaochun
    Duan, Wangping
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (08):
  • [39] The novel magnesium-titanium hybrid cannulated screws for the treatment of vertical femoral neck fractures: Biomechanical evaluation
    Zhang, Qida
    Chen, Zhenxian
    Peng, Yinghu
    Jin, Zhongmin
    Qin, Ling
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2023, 42 : 127 - 136
  • [40] Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures
    Kaplan, Tolga
    Akesen, Burak
    Demirag, Burak
    Bilgen, Sadik
    Durak, Kemal
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2012, 18 (01): : 65 - 70