Fixation of femoral neck fractures using divergent versus parallel cannulated screws

被引:2
|
作者
Papanastassiou I.D. [1 ,2 ]
Mavrogenis A.F. [2 ]
Kokkalis Z.T. [2 ]
Nikolopoulos K. [2 ]
Skourtas K. [1 ]
Papagelopoulos P.J. [2 ]
机构
[1] First Department of Orthopedics, KAT Hospital, Athens
[2] First Department of Orthopedics, Athens University Medical School, Athens
关键词
Cannulated screws; Divergent; Femoral neck fractures; Internal fixation; Parallel; Stainless steel;
D O I
10.1615/JLongTermEffMedImplants.v21.i1.50
中图分类号
学科分类号
摘要
Controversy exists regarding the optimal method of internal fixation in femoral neck fractures. Biomechanical data suggest that calcar fixation is superior to central screws placement. We propose a divergent technique for placing 3 cannulated stainless steel screws engaging the calcar femorale. Fiftytwo patients admitted to our institution for a femoral neck fracture were treated with the divergent screw technique, over a 7-year period. Four patients were deceased and 4 were lost to follow-up. Of the remaining 44 patients there were 10 males and 34 females, aged from 33 to 78 years (mean, 58 years). All patients were operated on by the same surgeon and were followed-up for a minimum of 2 years (mean: 33.6 months, range: 2-6 years). Twenty-four patients sustained a non-displaced fracture (Garden I-II) and 20 sustained a displaced fracture (Garden III-IV) of the femoral neck. Mean Harris hip score (HHS) was 89.6 points. Avascular necrosis was evident in 4 patients (9%) with displaced fractures. Non-unions or failed internal fixations were not encountered. There was a significant difference in the HHS, in favor of the divergent group (P = 0.006), while more complications were encountered in the parallel group including 6 cases with non-union. In conclusion, parallel screw placement is not critical for an excellent clinical outcome. Our proposed fixation method using 3 screws that diverge and lie in diff erent coronal planes (1 engaging the calcar femorale) with a free-hand technique may off er enhanced fixation. Biomechanical data along with larger clinical studies are needed to establish our proposed method. © 2011 by Begell House, Inc.
引用
收藏
页码:63 / 69
页数:6
相关论文
共 50 条
  • [1] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [2] Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study
    Yan, Shuang G.
    Cui, Yiliang
    Li, Di
    Liu, Fanxiao
    Hua, Xingyi
    Schmidutz, Florian
    JOURNAL OF INVESTIGATIVE SURGERY, 2023, 36 (01)
  • [3] The Effect of Configuration of Rhombic Cannulated Screws on Internal Fixation of Femoral Neck Fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Yingchao
    Zhang, Ruipeng
    Hou, Zhiyong
    Zhang, Yingze
    ORTHOPEDICS, 2020, 43 (02) : E72 - E78
  • [4] The Targon Femoral Neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip
    Griffin, X. L.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 652 - 657
  • [5] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667
  • [6] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Weil, Yoram A.
    Qawasmi, Feras
    Liebergall, Meir
    Mosheiff, Rami
    Khoury, Amal
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (05) : 661 - 667
  • [7] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [8] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Kai-xuan Yuan
    Fan Yang
    Kai Fu
    Dao-yu Zhu
    Chen-yi Jiang
    Dong-xu Jin
    Ze-hao Wang
    Xiao-yuan Peng
    You-Shui Gao
    Peng-bo Luo
    Journal of Orthopaedic Surgery and Research, 17
  • [9] Fixation using cannulated screws and fibular strut grafts for fresh femoral neck fractures with posterior comminution
    Zahid, Mohammad
    Bin Sabir, Aamir
    Asif, Naiyer
    Julfiqar, Mohammad
    Khan, A. Q.
    Ahmad, Sohail
    Siddiqui, Yasir S.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (02): : 191 - 195
  • [10] Nonanatomical Reduction of Femoral Neck Fractures in Young Patients (≤65 Years Old) with Internal Fixation Using Three Parallel Cannulated Screws
    Zhao, Guanglei
    Liu, Changquan
    Chen, Kangming
    Lyu, Jinyang
    Chen, Jie
    Shi, Jingsheng
    Chen, Feiyan
    Wei, Yibing
    Wang, Siqun
    Xia, Jun
    Huang, Gangyong
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021