A low-cost, colorimeter-based portable device, for rapid, on-spot determination of fluoride in water

被引:2
|
作者
Awasthi, Vishwesh Dutt [1 ]
Ramachandran, Shankar [2 ]
Bandyopadhyaya, Rajdip [2 ]
机构
[1] Indian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai, India
[2] Indian Inst Technol, Chem Engn Dept, Mumbai, India
关键词
Fluoride; LEDphototransistor; on-spot sensor; sensor device; selectivity; SENSOR; ION;
D O I
10.1080/03067319.2023.2219973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
xAccurate fluoride measurement in water is required for selecting safe water sources or for treatment options to lessen its impact on public health. A low-cost, portable device has been developed as a rapid fluoride measurement system. It works with an optimal concentration of alizarin red S-zirconium complex (ARS-Zr, the sensor reagent). The device is an LED-phototransistor-based assembly to detect changes in light absorbance at 527 nm, due to monotonically decreasing ARS-Zr concentration with increasing fluoride concentration in water. We have optimised reagent composition in the device, enabling us with a wider fluoride detection range (0.2-9 ppm), rapidly within 4 min; simultaneously ensuring better reagent stability for up to 34 days. Limit of detection (LOD) and limit of quantification (LOQ) of the device are 0.2 and 0.6 ppm, respectively. The device replicates an analytical spectrophotometer's performance, with a maximum error up to 5% in only a couple of cases. The hand-held device does not give any interference in the presence of even a very high 200 ppm concentration of other common heavy metals (Ca2+, Zn2+,Fe2+, Mg2+,Cu2+) and anions (Cl, NO 3, SO2 (4-), I, CH3COO-, CO2 (3-)), which can be present in water. Fluoride concentration measurement above 1 ppm is unaffected, by even high phosphate concentration up to 10 ppm (typical phosphate level being only = 2.3 ppm). Similarly, for silica concentration up to 10 ppm (typical silica level being 1-30 ppm), fluoride measurement remains unaffected. However, the presence of Fe3thorn gives significant interference with fluoride. Overall, we demonstrate the device as an on-spot method, for rapid fluoride measurement, independent of TDS (57.6-151 ppm), pH (6.6-12.5) or conductivity (111.2-283 mu S/ cm) of the samples, at a low device cost of US$ 25 and reagent cost of 0.44 cents per sample.
引用
收藏
页码:8977 / 8992
页数:16
相关论文
共 50 条
  • [31] Design and Validation of a Low-Cost Portable Device to Quantify Postural Stability
    Zhu, Yong
    SENSORS, 2017, 17 (03)
  • [32] RAPID AND LOW-COST DETERMINATION OF HEAVY METALS IN SOIL USING AN X-RAY PORTABLE INSTRUMENT
    Ulmanu, Mihaela
    Anger, Ildiko
    Gament, Eugenia
    Mihalache, M.
    Neagu, Eleonora
    Ilie, L.
    SCIENTIFIC PAPERS-SERIES A-AGRONOMY, 2011, 54 : 69 - 76
  • [33] PCB technology-based electrochemiluminescence microfluidic device for low-cost portable analytical systems
    Pittet, Patrick
    Lu, Guo-Neng
    Galvan, Jean-Marc
    Ferrigno, Rosaria
    Blum, Loic J.
    Leca-Bouvier, Beatrice D.
    IEEE SENSORS JOURNAL, 2008, 8 (5-6) : 565 - 571
  • [34] Low-cost, portable open-source gas monitoring device based on chemosensory technology
    Gotor, Raul
    Gavina, Pablo
    Costero, Ana M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (08)
  • [35] Field-Portable, Rapid, and Low-Cost RT-LAMP Assay for the Detection of Tomato Chlorotic Spot Virus
    Yilmaz, Salih
    Adkins, Scott
    Batuman, Ozgur
    PHYTOPATHOLOGY, 2022, : 567 - 576
  • [36] An Artificial Intelligence-Assisted Portable Low-Cost Device for the Rapid Detection of SARS-CoV-2
    Tharmakulasingam, Mukunthan
    Chaudhry, Nouman S.
    Branavan, Manoharanehru
    Balachandran, Wamadeva
    Poirier, Aurore C.
    Rohaim, Mohammed A.
    Munir, Muhammad
    La Ragione, Roberto M.
    Fernando, Anil
    ELECTRONICS, 2021, 10 (17)
  • [37] Low-Cost, Robust, and Field Portable Smartphone Platform Photometric Sensor for Fluoride Level Detection in Drinking Water
    Hussain, Iftak
    Ahamad, Kamal Uddin
    Nath, Pabitra
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 767 - 775
  • [38] Low-Cost and Rapid Shaping of Nitinol for Medical Device Prototyping
    Yip, Mighten C.
    Alaie, Seyedhamidreza
    Romito, Eva A.
    Doshi, Tejas
    Moghadam, Amir Ali Amiri
    Mosadegh, Bobak
    ASME Open Journal of Engineering, 2023, 2
  • [39] Design of a low-cost water quality assessment device based on a reference instrument
    Taamte, Jacob Mbarndouka
    Danwe, Yvette Frida
    Signing, Vitrice Ruben Folifack
    Gondji, Dieu Souffit
    Koyang, Francois
    Saidou
    URBAN WATER JOURNAL, 2025, 22 (04) : 397 - 418
  • [40] Development of a Low-Cost Portable Device for Identification of Parathyroid Glands Using Autofluorescence
    Serra, Carlos
    Silveira, Luis
    Canudo, Antonio
    INDIAN JOURNAL OF SURGERY, 2020, 82 (06) : 1126 - 1130