A low-cost, colorimeter-based portable device, for rapid, on-spot determination of fluoride in water

被引:2
|
作者
Awasthi, Vishwesh Dutt [1 ]
Ramachandran, Shankar [2 ]
Bandyopadhyaya, Rajdip [2 ]
机构
[1] Indian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai, India
[2] Indian Inst Technol, Chem Engn Dept, Mumbai, India
关键词
Fluoride; LEDphototransistor; on-spot sensor; sensor device; selectivity; SENSOR; ION;
D O I
10.1080/03067319.2023.2219973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
xAccurate fluoride measurement in water is required for selecting safe water sources or for treatment options to lessen its impact on public health. A low-cost, portable device has been developed as a rapid fluoride measurement system. It works with an optimal concentration of alizarin red S-zirconium complex (ARS-Zr, the sensor reagent). The device is an LED-phototransistor-based assembly to detect changes in light absorbance at 527 nm, due to monotonically decreasing ARS-Zr concentration with increasing fluoride concentration in water. We have optimised reagent composition in the device, enabling us with a wider fluoride detection range (0.2-9 ppm), rapidly within 4 min; simultaneously ensuring better reagent stability for up to 34 days. Limit of detection (LOD) and limit of quantification (LOQ) of the device are 0.2 and 0.6 ppm, respectively. The device replicates an analytical spectrophotometer's performance, with a maximum error up to 5% in only a couple of cases. The hand-held device does not give any interference in the presence of even a very high 200 ppm concentration of other common heavy metals (Ca2+, Zn2+,Fe2+, Mg2+,Cu2+) and anions (Cl, NO 3, SO2 (4-), I, CH3COO-, CO2 (3-)), which can be present in water. Fluoride concentration measurement above 1 ppm is unaffected, by even high phosphate concentration up to 10 ppm (typical phosphate level being only = 2.3 ppm). Similarly, for silica concentration up to 10 ppm (typical silica level being 1-30 ppm), fluoride measurement remains unaffected. However, the presence of Fe3thorn gives significant interference with fluoride. Overall, we demonstrate the device as an on-spot method, for rapid fluoride measurement, independent of TDS (57.6-151 ppm), pH (6.6-12.5) or conductivity (111.2-283 mu S/ cm) of the samples, at a low device cost of US$ 25 and reagent cost of 0.44 cents per sample.
引用
收藏
页码:8977 / 8992
页数:16
相关论文
共 50 条
  • [21] Probolino: A Portable Low-Cost Social Device for Home-Based Autism Therapy
    Cao, Hoang-Long
    Pop, Cristina
    Simut, Ramona
    Furnemont, Raphael
    De Beir, Albert
    Van de Perre, Greet
    Esteban, Pablo Gomez
    Lefeber, Dirk
    Vanderborght, Bram
    SOCIAL ROBOTICS (ICSR 2015), 2015, 9388 : 93 - 102
  • [22] RAPID LOW-COST MOISTURE DETERMINATION SYSTEM
    SOLBERG, M
    RIHA, WE
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1971, 54 (05): : 1009 - &
  • [23] Development of a Simple and Low-cost Device for Fluorometric Determination of Selenium in Water Samples
    Yasutada Suzuki
    Naoki Hashigaya
    Susumu Kawakubo
    Analytical Sciences, 2010, 26 : 719 - 722
  • [24] Development of a Simple and Low-cost Device for Fluorometric Determination of Selenium in Water Samples
    Suzuki, Yasutada
    Hashigaya, Naoki
    Kawakubo, Susumu
    ANALYTICAL SCIENCES, 2010, 26 (06) : 719 - 722
  • [25] Rapid prototyping of paper-based microfluidics with wax for low-cost, portable bioassay
    Lu, Yao
    Shi, Weiwei
    Jiang, Lei
    Qin, Jianhua
    Lin, Bingcheng
    ELECTROPHORESIS, 2009, 30 (09) : 1497 - 1500
  • [26] Open-Source Portable Device for the Determination of Fluoride in Drinking Water
    Otal, Eugenio H.
    Kim, Manuela Leticia
    Dietrich, Steffen
    Takada, Ryogo
    Nakaya, Shinji
    Kimura, Mutsumi
    ACS SENSORS, 2021, 6 (01) : 259 - 266
  • [27] Design and demonstration of a portable and low-cost Raman spectrometer for rapid and low-cost estimation of marker molecules in plants
    Sing, Dilip
    Banerjee, Subhadip
    Jana, Shibu Narayan
    Mallik, Ranajoy
    Dastidar, Sudarshana Ghosh
    Majumdar, Kalyan
    Bandyopadhyay, Amitabha
    Haldar, Pallab Kanti
    Sharma, Nanaocha
    Mukherjee, Pulok K.
    Bandyopadhyay, Rajib
    SPECTROSCOPY LETTERS, 2022, 55 (08) : 527 - 533
  • [28] Combination of a smart phone based low-cost portable colorimeter with air-assisted liquid-liquid microextraction for speciation and determination of chromium (III) and (VI)
    Khoshmaram, Leila
    Mohammadi, Maryam
    MICROCHEMICAL JOURNAL, 2021, 164
  • [29] Evaluation of a low-cost portable NIRS device for monitoring muscle ischemia
    Marrero-Garcia, Ramses
    Cruz-Tabares, Yaiza
    Gonzalez-Cava, Jose M.
    Mendez-Perez, Juan Albino
    Reboso-Morales, Jose Antonio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024,
  • [30] Portable Microwave Head Imaging Device using Low-Cost VNA
    Hashir, Muhammad
    Mahmood, Muhammad Q.
    Riaz, Kashif
    Zubair, Muhammad
    2022 IEEE USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2022, : 38 - 39