A low-cost, colorimeter-based portable device, for rapid, on-spot determination of fluoride in water

被引:2
|
作者
Awasthi, Vishwesh Dutt [1 ]
Ramachandran, Shankar [2 ]
Bandyopadhyaya, Rajdip [2 ]
机构
[1] Indian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai, India
[2] Indian Inst Technol, Chem Engn Dept, Mumbai, India
关键词
Fluoride; LEDphototransistor; on-spot sensor; sensor device; selectivity; SENSOR; ION;
D O I
10.1080/03067319.2023.2219973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
xAccurate fluoride measurement in water is required for selecting safe water sources or for treatment options to lessen its impact on public health. A low-cost, portable device has been developed as a rapid fluoride measurement system. It works with an optimal concentration of alizarin red S-zirconium complex (ARS-Zr, the sensor reagent). The device is an LED-phototransistor-based assembly to detect changes in light absorbance at 527 nm, due to monotonically decreasing ARS-Zr concentration with increasing fluoride concentration in water. We have optimised reagent composition in the device, enabling us with a wider fluoride detection range (0.2-9 ppm), rapidly within 4 min; simultaneously ensuring better reagent stability for up to 34 days. Limit of detection (LOD) and limit of quantification (LOQ) of the device are 0.2 and 0.6 ppm, respectively. The device replicates an analytical spectrophotometer's performance, with a maximum error up to 5% in only a couple of cases. The hand-held device does not give any interference in the presence of even a very high 200 ppm concentration of other common heavy metals (Ca2+, Zn2+,Fe2+, Mg2+,Cu2+) and anions (Cl, NO 3, SO2 (4-), I, CH3COO-, CO2 (3-)), which can be present in water. Fluoride concentration measurement above 1 ppm is unaffected, by even high phosphate concentration up to 10 ppm (typical phosphate level being only = 2.3 ppm). Similarly, for silica concentration up to 10 ppm (typical silica level being 1-30 ppm), fluoride measurement remains unaffected. However, the presence of Fe3thorn gives significant interference with fluoride. Overall, we demonstrate the device as an on-spot method, for rapid fluoride measurement, independent of TDS (57.6-151 ppm), pH (6.6-12.5) or conductivity (111.2-283 mu S/ cm) of the samples, at a low device cost of US$ 25 and reagent cost of 0.44 cents per sample.
引用
收藏
页码:8977 / 8992
页数:16
相关论文
共 50 条
  • [1] Development of a low-cost portable colorimeter for the estimation of fluoride in drinking water
    Rohit
    Kanwar, Lalita
    Rao, K. Kesava
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01): : 245 - 251
  • [2] Development of a low-cost portable colorimeter for the estimation of fluoride in drinking water (vol 149, pg 245, 2010)
    Rohit
    Kanwar, Lalita
    Rao, K. Kesava
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 158 (01) : 441 - 441
  • [3] A low-cost device for the estimation of fluoride in drinking water
    Sen, A
    Rao, KK
    Frizzell, MA
    Rao, G
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1998, 2 (01): : 51 - 58
  • [4] Rapid Low-Cost Determination of Lead(II) in Cassava by an iPod-Based Digital Imaging Colorimeter
    Wongthanyakram, Juthathip
    Masawat, Prinya
    ANALYTICAL LETTERS, 2019, 52 (03) : 550 - 561
  • [5] Construction and Characterization of a Compact, Portable, Low-Cost Colorimeter for the Chemistry Lab
    Clippard, Carrie M.
    Hughes, William
    Chohan, Balwant S.
    Sykes, Danny G.
    JOURNAL OF CHEMICAL EDUCATION, 2016, 93 (07) : 1241 - 1248
  • [6] Development of a low-cost portable POCT device based on ARM
    Xing, Xiaodong
    Huang, Xiangting
    Jin, Ying
    Wang, Liquan
    28TH CIRP DESIGN CONFERENCE 2018, 2018, 70 : 302 - 306
  • [7] A rapid and low cost-sensitive method of on-spot detection of RDX (Cyclonite)
    Sharma, S. P.
    Lahiri, S. C.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2006, 83 (09) : 934 - 935
  • [8] A cost-effective handheld device and smartphone application: Simplifying precise and rapid on-spot chromium(VI) detection in water
    Meshram, Swapnil
    Bandyopadhyaya, Rajdip
    TALANTA, 2025, 291
  • [9] A portable device for quick, on-spot, total arsenic measurement over a wide concentration range in water
    Awasthi, Vishwesh Dutt
    Singh, Satya Prakash
    Ramachandran, Shankar
    Bandyopadhyaya, Rajdip
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (05):
  • [10] Development of a low-cost colorimeter and its application for determination of environmental pollutants
    Le Quoc Hoang
    Huynh Bui Linh Chi
    Dang Nguyen Nha Khanh
    Ngo Thi Tuong Vy
    Phan Xuan Hanh
    Truong Nguyen Vu
    Hoang Thuc Lam
    Nguyen Thi Kim Phuong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 249