Bayesian estimation to deconvolute single-particle ICP-MS data with a mixed Poisson distribution

被引:1
|
作者
Suzuki, Yoshinari [1 ]
Kondo, Midori [1 ]
Harimoto, Masae [1 ]
Okamoto, Yusuke [1 ]
Tanaka, Yu-ki [2 ]
Ogra, Yasumitsu [2 ]
Akiyama, Hiroshi [1 ,3 ]
机构
[1] Natl Inst Hlth Sci, Div Foods, 3-25-26 Tonomachi,Kawasaki Ku, Kawasaki, Kanagawa 2109501, Japan
[2] Chiba Univ, Grad Sch Pharmaceut Sci, 1-8-1 Inohana,Chuo Ku, Chiba, Chiba 2608675, Japan
[3] Hoshi Univ, Dept Analyt Chem, 2-4-41 Ebara,Shinagawa Ku, Tokyo 1428501, Japan
关键词
PLASMA-MASS SPECTROMETRY; TRANSPORT EFFICIENCY; DATA-ACQUISITION; NANOPARTICLES; TIME; CAPABILITIES; RESOLUTION;
D O I
10.1039/d3ja00220a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Single-particle ICP-MS (spICP-MS) is an established method for the determination of inorganic nanoparticle (NP) mass distributions and particle number concentrations. However, spICP-MS is not applicable to some cases, especially cases that require distinguishing signals from dissolved ions and signals from relatively small NPs. To deconvolute spICP-MS data, which is obtained by setting the dwell time similar to the particle event duration time, a Bayesian estimation method was developed for spICP-MS analysis using silver (Ag) and silica (SiO2) NPs. The signal distributions of the spICP-MS data were parameterised using a Bayesian estimation method on the assumption that they could be described by mixed Poisson distributions. Analytical results were then compared to results obtained with conventional criteria. When the instrument parameters were set so that the particle-event duration was within 2 readings and hence did not deviate from the assumptions of the current Bayesian model, better estimation results could be obtained with the Bayesian estimation method than with methods based on conventional criteria, especially for a sample with high particle number concentration. Furthermore, applying the specific informative prior distribution enabled us to obtain reasonable estimation results, even when the signal counts were 6 or less and the background counts were high. Because appropriate NP information was obtained for Ag-NP and SiO2-NP, the Bayesian estimation method can be universally adopted with inorganic NPs detectable by ICP-MS. Model parameters (mean particle-event intensity and frequency, etc.) were directly estimated using the Bayesian method without summing particle-event intensities. Model parameters were transformed to NP information.
引用
收藏
页码:190 / 203
页数:14
相关论文
共 50 条
  • [31] Advancing Simultaneous Extraction and Sequential Single-Particle ICP-MS Analysis for Metallic Nanoparticle Mixtures in Plant Tissues
    Xu, Lei
    Ma, Xingmao
    Yang, John
    Burken, Joel G.
    Nam, Paul
    Shi, Honglan
    Yang, Hu
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2024, 72 (19) : 11251 - 11258
  • [32] Detection of nanoparticles in edible plant tissues exposed to nano-copper using single-particle ICP-MS
    Arturo A. Keller
    Yuxiong Huang
    Jenny Nelson
    Journal of Nanoparticle Research, 2018, 20
  • [33] Agarose-Droplet-Based Digital LAMP Assay for Counting Virus DNA in Single-Particle ICP-MS
    Yin, Xiao
    Chen, Beibei
    He, Man
    Hu, Bin
    ANALYTICAL CHEMISTRY, 2022, 94 (17) : 6582 - 6590
  • [34] Detection of nanoparticles in edible plant tissues exposed to nano-copper using single-particle ICP-MS
    Keller, Arturo A.
    Huang, Yuxiong
    Nelson, Jenny
    JOURNAL OF NANOPARTICLE RESEARCH, 2018, 20 (04)
  • [35] Exploring single-particle ICP-MS as an important tool for the characterization and quantification of silver nanoparticles in a soybean cell culture
    Silva, Ana Beatriz Santos da
    Arruda, Marco Aurelio Zezzi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 203
  • [36] Validation of Gold and Silver Nanoparticle Analysis in Fruit Juices by Single-Particle ICP-MS without Sample Pretreatment
    Witzler, Markus
    Kuellmer, Fabian
    Hirtz, Annika
    Guenther, Klaus
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (20) : 4165 - 4170
  • [37] Evaluation of collision/reaction gases in single-particle ICP-MS for sizing selenium nanoparticles and assessment of their antibacterial activity
    Freire, Bruna Moreira
    Cavalcanti, Yasmin Tavares
    Lange, Camila Neves
    Pieretti, Joana Claudio
    Pereira, Rodrigo Mendes
    Goncalves, Marcelly Chue
    Nakazato, Gerson
    Seabra, Amedea Barozzi
    Batista, Bruno Lemos
    NANOTECHNOLOGY, 2022, 33 (35)
  • [38] Validation of Single Particle ICP-MS for Routine Measurements of Nanoparticle Size and Number Size Distribution
    Bustos, Antonio R. Montoro
    Purushotham, Kavuri P.
    Possolo, Antonio
    Farkas, Natalia
    Vladar, Andras E.
    Murphy, Karen E.
    Winchester, Michael R.
    ANALYTICAL CHEMISTRY, 2018, 90 (24) : 14376 - 14386
  • [39] Innovations in single particle and single cell ICP-MS - Accurate measurements of particle number in cells
    Stephan, Chady
    Merrifield, Ruth
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [40] Simultaneous multi-element and multi-isotope detection in single-particle ICP-MS analysis: Principles and applications
    Tian, Xiangwei
    Jiang, Haowen
    Hu, Ligang
    Wang, Meng
    Cui, Wenbin
    Shi, Jianbo
    Liu, Guangliang
    Yin, Yongguang
    Cai, Yong
    Jiang, Guibin
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157