Three-dimensional finite element modeling of anisotropic materials using X-ray computed micro-tomography data

被引:1
|
作者
Ferguson, Ole Villiam [1 ,2 ]
Mikkelsen, Lars Pilgaard [2 ]
机构
[1] LM Wind Power, Jupitervej 6, DK-6000 Kolding, Denmark
[2] Tech Univ Denmark, DTU Wind & Energy Syst, DK-4000 Roskilde, Denmark
关键词
Structure tensor analysis; Fiber-reinforced polymers; Fiber orientation distribution; Constitutive behavior;
D O I
10.1016/j.simpa.2023.100523
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
A complete software package is developed for finite element modeling of anisotropic materials with orientation information estimated from X-ray & mu;CT scans. The method is demonstrated for a carbon fiber-reinforced epoxy pultruded profile where fiber orientations are estimated using structure tensor analysis. A finite element model is automatically generated with the same dimensions as the X-ray & mu;CT volume and with orientation information stored at the integration points of the mesh. A static tensile simulation is executed in AbaqusTM, and results are exported to a Python program for post-processing and analysis of the mechanical response.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Dimensional Standard for Micro X-ray Computed Tomography
    Patterson, Brian M.
    Hamilton, Christopher E.
    ANALYTICAL CHEMISTRY, 2010, 82 (20) : 8537 - 8543
  • [42] Micro-tomography based Geometry Modeling of Three-Dimensional Braided Composites
    Fang, Guodong
    Chen, Chenghua
    Yuan, Shenggang
    Meng, Songhe
    Liang, Jun
    APPLIED COMPOSITE MATERIALS, 2018, 25 (03) : 469 - 483
  • [43] X-ray fluorescence micro-tomography and laminography using an x-ray scanning microscope
    Watanabe, N.
    Hoshinol, M.
    Yamamoto, K.
    Aoki, S.
    Takeuchi, A.
    Suzuki, Y.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [44] Fast X-ray micro-tomography for low-Z materials
    Xu, L.
    Chen, R.
    Du, G.
    Xie, H.
    Xiao, T.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [45] X-ray micro-tomography an attractive characterisation technique in materials science
    Salvo, L
    Cloetens, P
    Maire, E
    Zabler, S
    Blandin, JJ
    Buffière, JY
    Ludwig, W
    Boller, E
    Bellet, D
    Josserond, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 200 : 273 - 286
  • [46] Comprehensive study of biopolymer foam compression up to densification using X-ray micro-tomography and finite element computation
    Guessasma, Sofiane
    Nouri, Hedi
    EUROPEAN POLYMER JOURNAL, 2016, 84 : 715 - 733
  • [47] Three-dimensional visualization of ocellar interneurons of the orchid bee Euglossa imperialis using micro X-ray computed tomography
    Ribi, Willi
    Zeil, Jochen
    JOURNAL OF COMPARATIVE NEUROLOGY, 2017, 525 (17) : 3581 - 3595
  • [48] Morphological Analysis of Spherical Adsorptive Carbon Granules Using Three-Dimensional X-Ray Micro-computed Tomography
    Lzutsu, Ken-ichi
    Abe, Yasuhiro
    Yomota, Chikako
    Yoshid, Hiroyuki
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2020, 68 (02) : 179 - 180
  • [49] High-speed data acquisition for three-dimensional x-ray and neutron computed tomography
    Davis, AW
    Claytor, TN
    Sheats, MJ
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 246 - 255
  • [50] Overcoming the fragility - X-ray computed micro-tomography elucidates brachiopod endoskeletons
    Seidel, Ronald
    Lueter, Carsten
    FRONTIERS IN ZOOLOGY, 2014, 11