High-speed data acquisition for three-dimensional x-ray and neutron computed tomography

被引:5
|
作者
Davis, AW [1 ]
Claytor, TN [1 ]
Sheats, MJ [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
来源
关键词
computed tomography; neutron radiography; amorphous silicon; x-ray; nondestructive evaluation;
D O I
10.1117/12.363727
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography for nondestructive evaluation applications has been limited by system cost, resolution, and time requirements for three-dimensional data sets. FlashCT (Flat panel Amorphous Silicon High-Resolution Computed Tomography) is a system developed at Los Alamos National Laboratory to address these three problems(1). Developed around flat panel amorphous silicon detector array, FlashCT is suitable for low to medium energy x-ray and neutron computed tomography at 127-micron resolution. Overall system size is small, allowing rapid transportation to a variety of radiographic sources. System control software was developed in LabVIEW for Windows NT to allow multithreading of data acquisition, data correction, and staging motor control. The system control software simplifies data collection and allows fully automated control of the data acquisition process, leading toward remote or unattended operation. The first generation of the FlashCT Data Acquisition System was completed in August 1998, and since that rime the system has been tested using x-ray sources ranging in energy from 60 kV to 20MV. The system has also been used to collect data for thermal neutron computed tomography at the Los Alamos Neutron Science Center(LANSCE). System improvements have been proposed to provide faster data collection and greater dynamic range during data collection.
引用
下载
收藏
页码:246 / 255
页数:10
相关论文
共 50 条
  • [1] High-Speed X-Ray Fluorescence Computed Tomography
    Vernekohl, D.
    Xing, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E185 - E185
  • [2] Ultrafast three-dimensional x-ray computed tomography
    Bieberle, Martina
    Barthel, Frank
    Menz, Hans-Juergen
    Mayer, Hans-Georg
    Hampel, Uwe
    APPLIED PHYSICS LETTERS, 2011, 98 (03)
  • [3] Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+
    Brabant, Loes
    Vlassenbroeck, Jelle
    De Witte, Yoni
    Cnudde, Veerle
    Boone, Matthieu N.
    Dewanckele, Jan
    Van Hoorebeke, Luc
    MICROSCOPY AND MICROANALYSIS, 2011, 17 (02) : 252 - 263
  • [4] Fast Three-Dimensional Focused X-ray Luminescence Computed Tomography
    Lun, Michael C.
    Fang, Yile
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [5] Data fusion in neutron and X-ray computed tomography
    Schrapp, Michael J.
    Goldammer, Matthias
    Schulz, Michael
    Issani, Siraj
    Bhamidipati, Suryanarayana
    Boeni, Peter
    JOURNAL OF APPLIED PHYSICS, 2014, 116 (16)
  • [6] HIGH-SPEED 3-DIMENSIONAL X-RAY COMPUTED-TOMOGRAPHY - THE DYNAMIC SPATIAL RECONSTRUCTOR
    ROBB, RA
    HOFFMAN, EA
    SINAK, LJ
    HARRIS, LD
    RITMAN, EL
    PROCEEDINGS OF THE IEEE, 1983, 71 (03) : 308 - 319
  • [7] High-speed X-ray ptychographic tomography
    Darren Batey
    Christoph Rau
    Silvia Cipiccia
    Scientific Reports, 12
  • [8] Development of high-speed fluorescent x-ray micro-computed tomography
    Takeda, T
    Tsuchiya, Y
    Kuroe, T
    Zeniya, T
    Wu, J
    Thet-Thet-Lwin
    Yashiro, T
    Yuasa, T
    Hyodo, K
    Matsumura, K
    Dilmanian, FA
    Itai, Y
    Akatsuka, T
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1320 - 1323
  • [9] High-speed X-ray ptychographic tomography
    Batey, Darren
    Rau, Christoph
    Cipiccia, Silvia
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] HIGH-SPEED, MULTI-SLICE, X-RAY COMPUTED-TOMOGRAPHY
    BOYD, DP
    COUCH, JL
    NAPEL, SA
    PARKER, DL
    PESCHMANN, KR
    RAND, RE
    HERRMANNSFELDT, WB
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 372 : 139 - 150