Establishment of an institutional diagnostic reference level for vascular lower extremity computed tomography angiography

被引:2
|
作者
Sulieman, Abdelmoneim [1 ]
Alkhorayef, Mohammed [2 ]
Alkhaybari, Essam [3 ]
Jaafar, Rasha [4 ]
Elnour, Abdelrahman [5 ]
Almujally, Abdullah [6 ]
Babikir, Esameldeen [7 ]
Abuzaid, Mohamed [8 ]
Abuhadi, Nouf [9 ]
Salah, Hassan [10 ]
Bradley, David A. [11 ]
机构
[1] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Appl Med Sci, Radiol Sci Dept, POB 2477, Al Hasa 31982, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[3] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[4] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Basic Sci Dept, Khartoum, Sudan
[5] Natl Ribat Univ, Coll Radiol & Nucl Med, Khartoum, Sudan
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[7] Univ Bahrain, Coll Hlth & Sport Sci, Radiol Technol Program, POB 32038, Manama, Bahrain
[8] Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah, U Arab Emirates
[9] Jazan Univ, Coll Appl Med Sci, Diagnost Radiog Technol Dept, Jazan, Saudi Arabia
[10] Inaya Med Coll, Dept Nucl Med Technol, POB 271 880, Riyadh 11352, Saudi Arabia
[11] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
CT angiography; Radiation risk; Diagnostic imaging; CT; ABDOMEN; CHEST; ACCURACY; EXPOSURE; ORGAN; SUDAN; RISK;
D O I
10.1016/j.radphyschem.2023.111460
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
About 70% of all collective doses from medical tests come from computed tomography (CT), the primary public radiation exposure source. Patients received higher doses during contrast-enhanced CT procedures (Angiography) than routine CT procedures. The current research aims to quantify the patients' radiation doses, estimate the cancer risk probability, and establish institutional diagnostic reference level (IDRL) during lower extremity angiography. One hundred eleven patients (61.3% male and 38.7% female) underwent contrast-enhanced CT procedures. A 160-Slice CT scanner was used for image acquisition for all patient populations. IDRL values were quantified based on the 3rd quartile value of the CT dose descriptors. All procedures were carried out at AlMoaallim Medical City, Khartoum, Sudan. A computer software (CT-Expo, ImPACT) was used to extrapolate the effective dosage per extremity CTA examination was estimated. The mean patient age (years) was 56.1 +/- 18 (18-82). The patient's radiation doses was quantified using volume CTDI and dose length product (DLP) to 7.3 +/- 2 (2.9-16.8) (mGy) and 3712 +/- 126 (279-8374) (mGy.cm), respectively. The average effective doses were 22 mSv (range: 1.7-50) per lower CT angiography for the lower extremity. The proposed IDRL for the VCTA procedure was 3562 mGy cm and 17 mGy for DLP and CTDIvol, respectively. The proposed IDRL is higher than the previously published studies; therefore, patient dose optimization is recommended.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Diagnostic reference levels for routine computed tomography angiography examinations: a systematic review
    Alhailiy, Ali Bahny
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [32] Computed Tomography Angiography of the Lower Extremities
    Cook, Tessa Sundaram
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2016, 54 (01) : 115 - +
  • [33] Diagnostic Accuracy of Coronary Computed Tomography Angiography for the Evaluation of Bioresorbable Vascular Scaffolds
    Collet, Carlos
    Serruys, Patrick
    Chevalier, Bernard
    Cequier, Angel
    Fajadet, Jean
    Van Boven, Ad
    Mcclean, Dougal
    Piek, Jan
    Bartorelli, Antonio
    Windecker, Stephan
    Onuma, Yoshinobu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B75 - B75
  • [34] Diagnostic reference level for computed tomography abdominal examinations: A multicentre study
    Sulieman, A.
    Elnour, A.
    Mahmoud, M. Z.
    Alkhorayef, M.
    Hamid, O.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 174
  • [35] National diagnostic reference level initiative for computed tomography examinations in Kenya
    Korir, Geoffrey K.
    Wambani, Jeska S.
    Korir, Ian K.
    Tries, Mark A.
    Boen, Patrick K.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (02) : 242 - 252
  • [36] Deep learning-based classification of lower extremity arterial stenosis in computed tomography angiography
    Dai, Lisong
    Zhou, Quan
    Zhou, Hongmei
    Zhang, Huijuan
    Cheng, Panpan
    Ding, Mingyue
    Xu, Xiangyang
    Zhang, Xuming
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [37] SIMPLE TECHNIQUE FOR IDENTIFICATION OF THE LOWER-EXTREMITY VASCULAR BUNDLE ON COMPUTED-TOMOGRAPHY
    BERMAN, H
    DUNNICK, NR
    DOPPMAN, JL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) : 282 - 283
  • [38] Computed Tomography Finding of Crusty Thrombosed Arteries: An Appearance of Lower Extremity Vascular Pythiosis
    Srisuwan, Tanop
    Kattipatanapong, Thanate
    Inmutto, Nakarin
    Reanpang, Termpong
    Rerkasem, Kittipan
    Arworn, Supapong
    INTERNATIONAL JOURNAL OF LOWER EXTREMITY WOUNDS, 2024,
  • [39] PATIENT GROUPING FOR DOSE SURVEYS AND ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVELS IN PAEDIATRIC COMPUTED TOMOGRAPHY
    Vassileva, J.
    Rehani, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 81 - 85
  • [40] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127