Sphygmomanometer Dynamic Pressure Measurement Using a Condenser Microphone

被引:0
|
作者
Tomazini, Zan [1 ]
Gersak, Gregor [1 ]
Begus, Samo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
关键词
RF microphone; blood pressure; low frequency; oscillometric; BP simulator; CALIBRATION; HYPERTENSION;
D O I
10.3390/s23198340
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a worldwide need to improve blood pressure (BP) measurement error in order to correctly diagnose hypertension. Cardiovascular diseases cause 17.9 million deaths annually and are a substantial monetary strain on healthcare. The current measurement uncertainty of 3 mmHg should be improved upon. Dynamic pressure measurement standards are lacking or non-existing. In this study we propose a novel method of measuring air pressure inside the sphygmomanometer tubing during BP measurement using a condenser microphone. We designed, built, and tested a system that uses a radiofrequency (RF) modulation method to convert changes in capacitance of a condenser microphone into pressure signals. We tested the RF microphone with a low-frequency (LF) sound source, BP simulator and using a piezoresistive pressure sensor as a reference. Necessary tests were conducted to assess the uncertainty budget of the system. The RF microphone prototype has a working frequency range from 0.5 Hz to 280 Hz in the pressure range from 0 to 300 mmHg. The total expanded uncertainty (k = 2, p = 95.5%) of the RF microphone was 4.32 mmHg. The proposed method could establish traceability of BP measuring devices to acoustic standards described in IEC 61094-2 and could also be used in forming dynamic BP standards.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Numerical determination of electric field forces and capacitance of pressure condenser microphone
    Dadic, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (06) : 1200 - 1203
  • [22] BLOOD-PRESSURE MEASUREMENT - AN EPITAPH FOR THE MERCURY SPHYGMOMANOMETER
    STEWART, MJ
    PADFIELD, PL
    CLINICAL SCIENCE, 1992, 83 (01) : 1 - 12
  • [23] Dynamic Behavior of Condenser Microphone Under the Influence of Squeeze Film Damping
    Zawawi, Siti Aisyah
    Hamzah, Azrul Azlan
    Selvarajan, Reena Sri
    Majlis, Burhanuddin Yeop
    Mohd-Yasin, Faisal
    2018 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE 2018), 2018, : 104 - 108
  • [24] Numerical determination of electric field forces and capacitance of pressure condenser microphone
    Dadic, M
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 971 - 974
  • [25] Accuracy of blood pressure measurement: sphygmomanometer calibration and beyond
    Parati, Gianfranco
    Faini, Andrea
    Castiglioni, Paolo
    JOURNAL OF HYPERTENSION, 2006, 24 (10) : 1915 - 1918
  • [27] Multilayer graphene condenser microphone
    Todorovic, Dejan
    Matkovic, Aleksandar
    Milicevic, Marijana
    Jovanovic, Djordje
    Gajic, Rados
    Salom, Iva
    Spasenovic, Marko
    2D MATERIALS, 2015, 2 (04):
  • [28] A NEW CONDENSER MICROPHONE IN SILICON
    BERGQVIST, J
    RUDOLF, F
    SENSORS AND ACTUATORS A-PHYSICAL, 1990, 21 (1-3) : 123 - 125
  • [29] A TRANSISTORIZED AMPLIFIER FOR A CONDENSER MICROPHONE
    NAKAMURA, J
    WAKABAYASHI, R
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1967, 15 (02): : 200 - +
  • [30] Modeling and simulation of a condenser microphone
    Chen, Jen-Yi
    Hsu, Yu-Chun
    Lee, Shu-Sheng
    Mukherjee, Tamal
    Fedder, Gary K.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 145 : 224 - 230