Sphygmomanometer Dynamic Pressure Measurement Using a Condenser Microphone

被引:0
|
作者
Tomazini, Zan [1 ]
Gersak, Gregor [1 ]
Begus, Samo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
关键词
RF microphone; blood pressure; low frequency; oscillometric; BP simulator; CALIBRATION; HYPERTENSION;
D O I
10.3390/s23198340
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a worldwide need to improve blood pressure (BP) measurement error in order to correctly diagnose hypertension. Cardiovascular diseases cause 17.9 million deaths annually and are a substantial monetary strain on healthcare. The current measurement uncertainty of 3 mmHg should be improved upon. Dynamic pressure measurement standards are lacking or non-existing. In this study we propose a novel method of measuring air pressure inside the sphygmomanometer tubing during BP measurement using a condenser microphone. We designed, built, and tested a system that uses a radiofrequency (RF) modulation method to convert changes in capacitance of a condenser microphone into pressure signals. We tested the RF microphone with a low-frequency (LF) sound source, BP simulator and using a piezoresistive pressure sensor as a reference. Necessary tests were conducted to assess the uncertainty budget of the system. The RF microphone prototype has a working frequency range from 0.5 Hz to 280 Hz in the pressure range from 0 to 300 mmHg. The total expanded uncertainty (k = 2, p = 95.5%) of the RF microphone was 4.32 mmHg. The proposed method could establish traceability of BP measuring devices to acoustic standards described in IEC 61094-2 and could also be used in forming dynamic BP standards.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Measurement and analysis of mastication muscle sound by using condenser microphone
    Hokari, Masaki
    Ito, Hiroshi
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2008, 74 (11): : 2683 - 2689
  • [2] COMPARISON OF THE BLOOD PRESSURE MEASUREMENT RESULTS USING MERCURY SPHYGMOMANOMETER AND OSCILLOMETRIC SPHYGMOMANOMETER
    Irawan, Visakha Revana
    Setiawan, Gerry
    Susanto, David
    Turana, Yuda
    JOURNAL OF HYPERTENSION, 2017, 35 : E8 - E8
  • [3] Structure and dynamic characteristics of silicon condenser micromachined microphone
    The Key Laboratory of Mechanical Manufacture and Automation of Ministry of Education, Zhejiang University of Technology, Hangzhou 310032, China
    Zhejiang Daxue Xuebao (Gongxue Ban), 2009, 7 (1260-1263+1336):
  • [4] INSTRUMENTATION FOR THE MEASUREMENT OF SOUND PRESSURE LEVEL WITH THE WESTERN ELECTRIC 640AA CONDENSER MICROPHONE
    VENEKLASEN, PS
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1948, 20 (06): : 807 - 817
  • [5] Optimum frequency of office blood pressure measurement using an automated sphygmomanometer
    Myers, Martin G.
    Valdivieso, Miguel
    Kiss, Alexander
    BLOOD PRESSURE MONITORING, 2008, 13 (06) : 333 - 338
  • [7] CONDENSER MICROPHONE SENSITIVITY MEASUREMENT BY REACTANCE TUBE NULL METHOD
    VONGIERKE, HE
    VONWITTERN, WW
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1951, 39 (06): : 633 - 635
  • [8] ABC OF BLOOD-PRESSURE MEASUREMENT - SPHYGMOMANOMETER
    OBRIEN, ET
    OMALLEY, K
    BRITISH MEDICAL JOURNAL, 1979, 2 (6194): : 851 - 853
  • [9] Miniature Condenser Microphone
    Hilliard, John K.
    JOURNAL OF THE SOCIETY OF MOTION PICTURE & TELEVISION ENGINEERS, 1950, 54 (03): : 303 - 314
  • [10] Condenser MEMS Microphone
    Grigoriev D.M.
    Generalov S.S.
    Polomoshnov S.A.
    Nikiforov S.V.
    Amelichev V.V.
    Russian Microelectronics, 2020, 49 (01) : 37 - 42