Mineral quantitative characterization method based on basis material decomposition model by dual-energy computed tomography

被引:0
|
作者
Zhi, Weijuan [1 ]
Zou, Jing [1 ]
Zhao, Jintao [2 ]
Xia, Xiaoqin [3 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300000, Peoples R China
[2] Tianjin Univ Technol & Educ, Tianjin Key Lab Informat Sensing & Intelligent Co, Tianjin, Peoples R China
[3] Zhejiang Normal Univ, Coll Math Med, Jinhua, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-energy computed tomography; basis material decomposition; mineral quantitative characterization; basis material determination; ATOMIC-NUMBER; CT; OPTIMIZATION; DENSITY;
D O I
10.3233/XST-221324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Dual-energy computed tomography (DECT) can reconstruct electron density rho(e) and effective atomic number Z(eff) distribution for material discrimination. Image-domain basis material decomposition (IBMD) method is a widely used DECT method. However, IBMD method cannot be used for mineral identification directly due to limitations of complex basis material determination, beam hardening artifacts, and inherent errors caused by approximate empirical formulas. OBJECTIVE: This study proposes an improved IBMD (IIBMD) method to overcome the above limitations. METHODS: In IIBMD method, the composition of basis material is optimized to obtain accurate decomposition coefficients, which enables accurate rho(e) and Zeff distribution. Moreover, the thickness of basis material is optimized to reduce the effect of beam hardening. Furthermore, two formulas in place of empirical formulas are proposed to calculate rho(e) and Zeff. Finally, a threshold technique is applied to separate different mineral phases. RESULTS: Numerical simulations and practical experiments using a photon-counting detector CT system are implemented to verify IIBMD method. Results show that the relative errors of rho(e) and Z(eff) for seven common minerals are down to 5%, lower than most of the existing DECT methods for rocks. Reasonable volume fraction results of mineral phases are thus obtained through threshold segmentation. CONCLUSIONS: This study demonstrates that the proposed IIBMD method has high practical value in mineralogical identification.
引用
收藏
页码:373 / 391
页数:19
相关论文
共 50 条
  • [1] A Novel Decomposition Method for Dual-energy Computed Tomography
    Li, Yuanji
    Zhang, Li
    Kang, Kejun
    Chen, Zhiqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] Opportunistic screening for osteoporosis using enhanced images based on dual-energy computed tomography material decomposition: a comparison with quantitative computed tomography
    Tong, Xiaoyu
    Fang, Xin
    Wang, Shigeng
    Fan, Yong
    Wei, Wei
    Xiao, Qingzhu
    Chen, Anliang
    Liu, Yijun
    Liu, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 352 - 364
  • [3] Dual-Energy Computed Tomography Material Decomposition Network Based on Mamba and Channel Attention
    Ge, Tianhao
    Kong, Fanning
    Shi, Zaifeng
    Jin, Yichao
    Cao, Qingjie
    LASER & OPTOELECTRONICS PROGRESS, 2025, 62 (02)
  • [4] Material decomposition for simulated dual-energy breast computed tomography via hybrid optimization method
    Komolafe, Temitope E.
    Du, Qiang
    Zhang, Yin
    Wu, Zhongyi
    Zhang, Cheng
    Li, Ming
    Zheng, Jian
    Yang, Xiaodong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1037 - 1054
  • [5] ACCURACY OF VERTEBRAL MINERAL DETERMINATION BY DUAL-ENERGY QUANTITATIVE COMPUTED-TOMOGRAPHY
    REINBOLD, WD
    ADLER, CP
    KALENDER, WA
    LENTE, R
    SKELETAL RADIOLOGY, 1991, 20 (01) : 25 - 29
  • [6] A Characterization of Deep Learning Reconstruction Applied to Dual-Energy Computed Tomography Monochromatic and Material Basis Images
    Nikolau, Ethan P.
    Toia, Giuseppe V.
    Nett, Brian
    Tang, Jie
    Szczykutowicz, Timothy P.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (03) : 437 - 444
  • [7] Adaptive Nonlocal Means Method for Denoising Basis Material Images From Dual-Energy Computed Tomography
    Yuan, Yuan
    Zhang, Yanbo
    Yu, Hengyong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 972 - 981
  • [8] Quantitative material analysis by dual-energy computed tomography for industrial NDT applications
    Nachtrab, F.
    Weis, S.
    Kessling, P.
    Sukowski, F.
    Hassler, U.
    Fuchs, T.
    Uhlmann, N.
    Hanke, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S159 - S162
  • [9] A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography
    Cai, C.
    Rodet, T.
    Legoupil, S.
    Mohammad-Djafari, A.
    MEDICAL PHYSICS, 2013, 40 (11)
  • [10] Dual-Energy Computed Tomography Three Material Decomposition Improves the Sensitivity of Gout Detection
    Tse, Justin
    Kondro, Douglas
    Pauchard, Yves
    Veljkovic, Andrea
    Frasson, Viviane
    Holdsworth, David
    Manske, Sarah
    MacMullan, Paul
    Salat, Peter
    ARTHRITIS & RHEUMATOLOGY, 2021, 73 : 355 - 357