A Novel Orthognathic Surgery With a Half-Millimeter Accuracy for the Maxillary Positioning Using Prebent Plates and Computer-Aided Design and Manufacturing Osteotomy Guide

被引:0
|
作者
Yamashita, Yosuke [1 ,3 ]
Imai, Haruki [1 ]
Takasu, Hikaru [1 ]
Omura, Susumu [1 ]
Fujita, Koichi [1 ]
Iwai, Toshinori [2 ]
Hirota, Makoto [1 ]
Mitsudo, Kenji [2 ]
机构
[1] Yokohama City Univ, Dept Oral & Maxillofacial Surg Orthodont, Med Ctr, Yokohama, Kanagawa, Japan
[2] Yokohama City Univ, Grad Sch Med, Dept Oral & Maxillofacial Surg, Yokohama, Kanagawa, Japan
[3] Dept Oral & Maxillofacial Surg Orthodont, Minami Ward, 4-57 Urafune Cho, Yokohama, Kanagawa 2320024, Japan
关键词
Computer-aided design and manufacturing osteotomy guide; 3-dimensional printing; guided surgery; orthognathic surgery; prebent plate; CUSTOMIZED SURGICAL GUIDES; TITANIUM PLATES;
D O I
10.1097/SCS.0000000000009409
中图分类号
R61 [外科手术学];
学科分类号
摘要
This retrospective study aimed to assess the accuracy of prebent plates and computer-aided design and manufacturing osteotomy guide for orthognathic surgery. The prebent plates correspondent to the planning model were scanned with a 3-dimensional printed model for guide design and used for fixation. Forty-two patients who underwent bimaxillary orthognathic surgery using computer-aided design and manufacturing intermediate splint with the guide (guided group: 20 patients) or with conventional fixation under straight locking miniplates (SLMs) technique (SLM group: 20 patients) were analyzed. A deviation of the maxilla between the planned and postoperative positions was evaluated using computed tomography, which was taken 2 weeks before and 4 days after the surgery. The surgery time and the infraorbital nerve paranesthesia were also evaluated. The mean deviations in the mediolateral (x), anteroposterior (y), and vertical directions (z) were 0.25, 0.50, and 0.37 mm, respectively, in the guided group, while that in the SLM group were 0.57, 0.52, and 0.82 mm, respectively. There were significant differences in x and z coordinates (P<0.001). No significant difference in the surgery duration and paranesthesia was seen, suggesting the present method offers a half-millimeter accuracy for the maxillary repositioning without increasing the risk of extending surgery duration and nerve complication.
引用
收藏
页码:2087 / 2091
页数:5
相关论文
共 47 条
  • [31] Simultaneous Computer-Aided Design/Computer-Aided Manufacture Bimaxillary Orthognathic Surgery and Mandibular Reconstruction Using Selective-Laser Sintered Titanium Implant
    Hatamleh, Muhanad M.
    Bhamrah, Gurprit
    Ryba, Francine
    Mack, Gavin
    Huppa, Chrisopher
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (07) : 1810 - 1814
  • [32] Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing
    Morita, Daiki
    Numajiri, Toshiaki
    Tsujiko, Shoko
    Nakamura, Hiroko
    Yamochi, Ryo
    Sowa, Yoshihiro
    Yasuda, Makoto
    Hirano, Shigeru
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (08) : 2060 - 2062
  • [33] Guided Endodontic Access in Maxillary Molars Using Cone-beam Computed Tomography and Computer-aided Design/Computer-aided Manufacturing System: A Case Report
    Lara-Mendes, Sonia T. de O.
    Barbosa, Camila de Freitas M.
    Santa-Rosa, Caroline C.
    Machado, Vinicius C.
    JOURNAL OF ENDODONTICS, 2018, 44 (05) : 875 - 879
  • [34] Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery
    Yoana Malenova
    Florian Ortner
    Paris Liokatis
    Selgai Haidari
    Matthias Tröltzsch
    Florian Fegg
    Katharina T. Obermeier
    Jens T. Hartung
    Tamara K. Kakoschke
    Egon Burian
    Sven Otto
    Hisham Sabbagh
    Florian A. Probst
    Clinical Oral Investigations, 2023, 27 : 5063 - 5072
  • [35] Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery
    Malenova, Yoana
    Ortner, Florian
    Liokatis, Paris
    Haidari, Selgai
    Troeltzsch, Matthias
    Fegg, Florian
    Obermeier, Katharina T.
    Hartung, Jens T.
    Kakoschke, Tamara K.
    Burian, Egon
    Otto, Sven
    Sabbagh, Hisham
    Probst, Florian A.
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (09) : 5063 - 5072
  • [36] A novel method of computer aided orthognathic surgery using individual CAD/CAM templates: a combination of osteotomy and repositioning guides
    Li, Biao
    Zhang, Lei
    Sun, Hao
    Yuan, Jianbing
    Shen, Steve G. F.
    Wang, Xudong
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (08): : E239 - E244
  • [37] Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
    Kohorst, Philipp
    Brinkmann, Henrike
    Li, Jiang
    Borchers, Lothar
    Stiesch, Meike
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (03) : 319 - 325
  • [38] Reduction in maxillary complete denture deformation using framework material made by computer-aided design and manufacturing systems
    Hada, Tamaki
    Suzuki, Tetsuya
    Minakuchi, Shunsuke
    Takahashi, Hidekazu
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 103
  • [39] Mini-Implant Insertion Using a Guide Manufactured with Computer-Aided Design and Computer-Aided Manufacturing in an Adolescent Patient Suffering from Tooth Eruption Disturbance
    Weismann, Christina
    Heise, Kathrin
    Aretxabaleta, Maite
    Cetindis, Marcel
    Koos, Bernd
    Schulz, Matthias C.
    BIOENGINEERING-BASEL, 2024, 11 (01):
  • [40] Use of the surface-based registration function of computer-aided design/computer- aided manufacturing software in medical simulation software for three-dimensional simulation of orthognathic surgery
    Kang, Sang-Hoon
    Lee, Jae-Won
    Kim, Moon-Key
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2013, 39 (04) : 197 - 199