Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing

被引:8
|
作者
Morita, Daiki [1 ]
Numajiri, Toshiaki [1 ]
Tsujiko, Shoko [1 ]
Nakamura, Hiroko [2 ]
Yamochi, Ryo [1 ]
Sowa, Yoshihiro [1 ]
Yasuda, Makoto [3 ]
Hirano, Shigeru [3 ]
机构
[1] Kyoto Prefectural Univ Med, Dept Plast & Reconstruct Surg, Kyoto, Japan
[2] Fukuchiyama City Hosp, Dept Plast & Reconstruct Surg, Fukuchiyma, Japan
[3] Kyoto Prefectural Univ Med, Dept Otolaryngol Head & Neck Surg, Kyoto, Japan
关键词
CAD/CAM; free scapular flap; maxillary reconstruction; orbital floor reconstruction; DEFECTS;
D O I
10.1097/SCS.0000000000004012
中图分类号
R61 [外科手术学];
学科分类号
摘要
Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.
引用
收藏
页码:2060 / 2062
页数:3
相关论文
共 50 条
  • [1] To Computer-Aided Design and Manufacturing or Not to Computer-Aided Design and Manufacturing? Free Fibula Flap With Computer-Aided Technique for Mandibular Reconstruction
    Zavattero, Emanuele
    Garzino-Demo, Paolo
    Fasolis, Massimo
    Ramieri, Guglielmo
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : E206 - E209
  • [2] Computer-Aided Design and Computer-Aided Manufacturing for Pelvic Tumor Resection and Free Fibula Flap Reconstruction
    Agrawal, Nikhil
    DeFazio, Michael V.
    Bird, Justin E.
    Mericli, Alexander F.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 145 (04) : 889E - 890E
  • [3] Accuracy of Computer-Aided Design/Computer-Aided Manufacturing-Assisted Mandibular Reconstruction With a Fibula Free Flap
    Geusens, Joris
    Sun, Yi
    Luebbers, Heinz-Theo
    Bila, Michel
    Darche, Vincent
    Politis, Constantinus
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : 2319 - 2323
  • [4] Computer-Aided Design and Computer-Aided Manufacturing Cutting Guides in Eminoplasty for the Treatment of Temporomandibular Joint Dislocation
    Xu, Chunwei
    Liu, Hanghang
    Du, Wen
    Wang, Yiyao
    Hu, Jian
    Luo, En
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (02) : 541 - 547
  • [5] Late reconstruction of the complex orbital fractures with computer-aided design and computer-aided manufacturing technique
    Fan, Xianqun
    Zhou, Huifang
    Lin, Ming
    Fu, Yao
    Li, Jin
    JOURNAL OF CRANIOFACIAL SURGERY, 2007, 18 (03) : 665 - 673
  • [6] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING
    WEINBERGSTABER, M
    DU-DIE ZEITSCHRIFT DER KULTUR, 1984, (02): : 89 - 89
  • [7] Multiple Buttresses Reconstruction of Maxilla with Fibular Flap Using Computer-aided Design/Computer-aided Manufacturing after Maxillectomy
    Kurosawa, Koreyuki
    Sato, Naoko
    Ohkoshi, Akira
    Harata, Takayuki
    Ishi, Shinyo
    Hayashi, Masanobu
    Imai, Toshiro
    Takamura, Nariaki
    Matsunaga, Hiromu
    Imai, Yoshimichi
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2024, 12 (06)
  • [8] Mandibular Reconstruction Using Computer-Aided Design and Computer-Aided Manufacturing: An Analysis of Surgical Results
    Foley, Benjamin D.
    Thayer, Wesly P.
    Honeybrook, Adam
    McKenna, Samuel
    Press, Steven
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (02) : E111 - E119
  • [9] Maxillary sinus augmentation using computer-aided design/computer-aided manufacturing (CAD/CAM) technology
    Mangano, F.
    Zecca, P.
    Pozzi-Taubert, S.
    Macchi, A.
    Ricci, M.
    Luongo, G.
    Mangano, C.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2013, 9 (03): : 331 - 338
  • [10] Computer-Aided Orbital Reconstruction
    Kinzinger M.
    Strong E.B.
    Current Otorhinolaryngology Reports, 2015, 3 (4) : 221 - 225