Contrast-enhanced Ultrasound (CEUS)-based Characterization Solid Renal Masses: A role for quantitative imaging approaches

被引:0
|
作者
Varghese, Bino A. [1 ]
Rivas, Marielena [2 ]
Cen, Steven [1 ]
Lei, Xiaomeng [1 ]
Chang, Michael [3 ]
Lee, KwangJu [4 ]
Gunter, Jamie [1 ]
Amoedo, Renata L. [5 ]
Franco, Mario [1 ]
Hwang, Darryl H. [1 ]
Desai, Bhushan [1 ]
King, Kevin G. [6 ]
Cheng, Phillip M. [1 ]
Duddalwar, Vinay [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Los Angeles, CA 90007 USA
[2] Univ Richmond, Med Ctr, New York, NY USA
[3] Icahn Sch Med Mt Sinai, New York, NY USA
[4] Samsung Medison Co Ltd, Seoul, South Korea
[5] Hosp Sao Rafael Rede Dor, Salvador, BA, Brazil
[6] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
关键词
CEUS; Radiomics; TIC; renal masses; visual assessment;
D O I
10.1117/12.2670366
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this prospective study, forty patients with solid renal masses who underwent contrast-enhanced ultrasound (CEUS) examinations were selected. Using the ImageJ software, renal masses and adjacent normal tissue were manually segmented from CEUS cine exams obtained using the built-in RS85 Samsung scanner software. For the radiomics analysis, one frame representing precontrast, early, peak, and delay enhancement phase were selected post segmentation from each CEUS clip. From each region of interest (ROI) within a tumor tissue normalized renal mass, 112 radiomic metrics were extracted using custom Matlab (R) code. For the time-intensity curve (TIC) analysis, the segmented ROIs were plotted as a function of time, and the data were fit to a washout curve. From these time-signal intensity curves, perfusion quantitative parameters, were generated. Wilcoxon rank sum test or univariate independent t-test depending on data normality were used for descriptive analyses. Agreement was analyzed using Kappa statistic. Of the 40 solid masses, 31 (77.5%) were malignant, 9 (22.5%) were benign based on histopathology. Excellent agreement was found between histopathological confirmation and visual assessment based on CEUS in discriminating solid renal masses into benign vs. malignant categories (kappa=0.89 95% confidence interval ( CI): (0.77,1)). The total agreement between the two was 92.5%. The sensitivity and specificity of CEUS-based visual assessment was found to be 100% and 66.7%, respectively. Quantitative analysis revealed TIC metrics revealed statistically significant differences between the malignant and benign groups and between clear cell renal cell carcinoma (ccRCC) and papillary renal cell carcinoma (pRCC) subtypes. The study shows excellent agreement between visual assessment and histopathology, but with the room to improve in specificity.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Contrast-enhanced Ultrasound (CEUS)-based Characterization Solid Renal Masses: A role for quantitative imaging approaches
    Varghese, Bino A.
    Rivas, Marielena
    Cen, Steven
    Lei, Xiaomeng
    Chang, Michael
    Lee, KwangJu
    Gunter, Jamie
    Amoedo, Renata L.
    Franco, Mario
    Hwang, Darryl H.
    Desai, Bhushan
    King, Kevin G.
    Cheng, Phillip M.
    Duddalwar, Vinay
    Proceedings of SPIE - The International Society for Optical Engineering, 2023, 12567
  • [2] Diagnostic Performance of Contrast-Enhanced Ultrasound (CEUS) in the Evaluation of Solid Renal Masses
    Geyer, Thomas
    Schwarze, Vincent
    Marschner, Constantin
    Schnitzer, Moritz L.
    Froelich, Matthias F.
    Ruebenthaler, Johannes
    Clevert, Dirk-Andre
    MEDICINA-LITHUANIA, 2020, 56 (11): : 1 - 8
  • [3] Contrast-enhanced ultrasound (CEUS) imaging for active surveillance of small renal masses
    Elena Bertelli
    Alberto Palombella
    Francesco Sessa
    Irene Baldi
    Noemi Morelli
    Silvia Verna
    Isabella Greco
    Simone Morselli
    Alessandro Pili
    Arcangelo Sebastianelli
    Alessandro Berni
    Rossella Nicoletti
    Andrea Minervini
    Marco Carini
    Mauro Gacci
    Vittorio Miele
    Simone Agostini
    Sergio Serni
    Riccardo Campi
    World Journal of Urology, 2021, 39 : 2853 - 2860
  • [4] Contrast-enhanced ultrasound (CEUS) imaging for active surveillance of small renal masses
    Bertelli, Elena
    Palombella, Alberto
    Sessa, Francesco
    Baldi, Irene
    Morelli, Noemi
    Verna, Silvia
    Greco, Isabella
    Morselli, Simone
    Pili, Alessandro
    Sebastianelli, Arcangelo
    Berni, Alessandro
    Nicoletti, Rossella
    Minervini, Andrea
    Carini, Marco
    Gacci, Mauro
    Miele, Vittorio
    Agostini, Simone
    Serni, Sergio
    Campi, Riccardo
    WORLD JOURNAL OF UROLOGY, 2021, 39 (08) : 2853 - 2860
  • [5] The current role of contrast-enhanced ultrasound (CEUS) imaging in the evaluation of renal pathology
    Siracusano, Salvatore
    Bertolotto, Michele
    Ciciliato, Stefano
    Valentino, Massimo
    Liguori, Giovanni
    Visalli, Francesco
    WORLD JOURNAL OF UROLOGY, 2011, 29 (05) : 633 - 638
  • [6] The current role of contrast-enhanced ultrasound (CEUS) imaging in the evaluation of renal pathology
    Salvatore Siracusano
    Michele Bertolotto
    Stefano Ciciliato
    Massimo Valentino
    Giovanni Liguori
    Francesco Visalli
    World Journal of Urology, 2011, 29
  • [7] Contrast-enhanced ultrasound (CEUS) of cystic and solid renal lesions: a review
    Mittul Gulati
    Kevin G. King
    Inderbir S. Gill
    Vivian Pham
    Edward Grant
    Vinay A. Duddalwar
    Abdominal Imaging, 2015, 40 : 1982 - 1996
  • [8] Contrast-enhanced ultrasound (CEUS) of cystic and solid renal lesions: a review
    Gulati, Mittul
    King, Kevin G.
    Gill, Inderbir S.
    Pham, Vivian
    Grant, Edward
    Duddalwar, Vinay A.
    ABDOMINAL IMAGING, 2015, 40 (06): : 1982 - 1996
  • [9] Contrast-enhanced Ultrasound of Renal Masses
    Bennett, Jack
    Peterson, Cynthia
    Barr, Richard G.
    APPLIED RADIOLOGY, 2020, 49 (06) : 10 - 16
  • [10] Contrast-Enhanced Ultrasound (CEUS) in Imaging of Renal Space Occupying Lesion: What Is Its Role?
    Vyas, J.
    Agrawal, V
    Ganpule, A.
    Mishra, S.
    Raghuram
    Sabnis, R.
    Desai, M.
    UROLOGY, 2012, 80 (03) : S60 - S60