Laser-induced graphene (LIG)-based Au@CuO/V2CTx MXene non-enzymatic electrochemical sensors for the urine glucose test

被引:73
|
作者
Cui, Feiyun [1 ]
Sun, Haiming [1 ]
Yang, Xueqiong [2 ]
Zhou, Hang [2 ]
Wu, Yiqi [1 ]
Li, Jing [1 ]
Li, Hongxia [1 ]
Liu, Jianlei [3 ]
Zeng, Chijia [3 ]
Qu, Bin [4 ]
Zhang, Jufan [1 ,5 ]
Zhou, Qin [1 ]
机构
[1] Harbin Med Univ, Sch Biomed Sci, Harbin 150081, Peoples R China
[2] Chongqing Med Univ, Sch Lab Med, Key Lab Clin Diagnost, Minist Educ, Chongqing 400016, Peoples R China
[3] Foshan Fosun Chancheng Hosp, Dept Lab Med & Pathol, Foshan 528000, Guangdong, Peoples R China
[4] Saarland Univ, Ctr Integrat Physiol & Mol Med CIPMM, Sch Med, Biophys, D-66421 Homburg, Germany
[5] Univ Coll Dublin, Ctr Micro Nano Mfg Technol MNMT Dublin, Sch Mech & Mat Engn, Dublin, Ireland
关键词
Nanozyme; Laser-induced graphene (LIG); Non-enzymatic glucose electrochemical sensor; Urine glucose test; V2CTx MXene; CORE-SHELL NANOPARTICLES; PEROXIDASE-LIKE ACTIVITY; BLOOD-GLUCOSE; INSULIN; OXIDE; NANOCOMPOSITE; NANOCRYSTALS; NANOSHEETS; ACID; CU2O;
D O I
10.1016/j.cej.2023.141303
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Glucose monitoring is of great significance for the health management of diabetic patients. Herein, non-enzymatic glucose sensors were developed by modifying Au@CuO or Au@CuO/V2CTx MXene nanocomposites (NCs) on the surface of disposable laser-induced graphene (LIG) electrode. The structures and morphologies were confirmed by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and elemental analysis. The electrochemical performances of NCs were investigated by electrochemical impedance spectros-copy (EIS), cyclic voltammetry (CV) and chronoamperometry (CA). The results demonstrated that both Au@CuO/LIG and Au@CuO/V2CTx MXene/LIG have excellent electrocatalytic activity for glucose oxidation in an alkaline medium. However, it was found that Au@CuO/V2CTx MXene/LIG was easily oxidized. Hence, the combination of Au@CuO/LIG was preferred for glucose test. Under optimized conditions, the electrochemical sensor achieved a detection range of 0.005 to 5.0 mM with a sensitivity of 1.124 x 106 mu A mM-1 cm-2. The response time was 1.5 s and the limit of detection (LOD) was as low as 1.8 mu M. The sensor has good selectivity and stability (84.12 % activity retained after 6 weeks). Its affordable price, disposable usage and portable essence are suitable for clinical application. Our study presented a novel strategy to the field of non-enzymatic glucose sensing.
引用
收藏
页数:10
相关论文
共 46 条
  • [1] Electrochemical non-enzymatic glucose sensors based on CuO nanostructures
    Yang, Jiahao
    Yin, Jing
    Xu, Lan
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1010
  • [2] Laser-induced graphene non-enzymatic glucose sensors for on-body measurements
    Zhu, Jia
    Liu, Shangbin
    Hu, Zhihui
    Zhang, Xianzhe
    Yi, Ning
    Tang, Kairui
    Dexheimer, Michael Gregory
    Lian, Xiaojun
    Wang, Qing
    Yang, Jian
    Gray, Jennifer
    Cheng, Huanyu
    BIOSENSORS & BIOELECTRONICS, 2021, 193
  • [3] Synthesis of Laser-Induced Cobalt Oxide for Non-Enzymatic Electrochemical Glucose Sensors
    Kang, Seung-Jo
    Pak, James Jungho
    CHEMELECTROCHEM, 2022, 9 (16)
  • [4] Sustainable electrochemical sensors from cork-derived laser induced graphene: Non-enzymatic glucose detection in urine
    Setti, Michele
    Vaughan, Eoghan
    Murray, Richard
    Sygellou, Labrini
    Quinn, Aidan J.
    Ricco, Mauro
    Pontiroli, Daniele
    Iacopino, Daniela
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 430
  • [5] Laser-induced graphene from paper for non-enzymatic uric acid electrochemical sensing in urine
    Kulyk, Bohdan
    Pereira, Sonia O.
    Fernandes, Antonio J. S.
    Fortunato, Elvira
    Costa, Florinda M.
    Santos, Nuno F.
    CARBON, 2022, 197 : 253 - 263
  • [6] A flexible non-enzymatic glucose sensor based on copper nanoparticles anchored on laser-induced graphene
    Zhang, Yue
    Li, Na
    Xiang, Yangjun
    Wang, Debo
    Zhang, Peng
    Wang, Yanyan
    Lu, Shan
    Xu, Rongqing
    Zhao, Jiang
    CARBON, 2020, 156 : 506 - 513
  • [7] Reusable electrochemical non-enzymatic glucose sensors based on Au-inlaid nanocages
    Shen, Lu
    Liang, Zhen
    Chen, Zhiyu
    Wu, Can
    Hu, Xuefeng
    Zhang, Jieyu
    Jiang, Qing
    Wang, Yunbing
    NANO RESEARCH, 2022, 15 (07) : 6490 - 6499
  • [8] Reusable electrochemical non-enzymatic glucose sensors based on Au-inlaid nanocages
    Lu Shen
    Zhen Liang
    Zhiyu Chen
    Can Wu
    Xuefeng Hu
    Jieyu Zhang
    Qing Jiang
    Yunbing Wang
    Nano Research, 2022, 15 : 6490 - 6499
  • [9] Laser-induced graphene decorated with Ni-Pt alloy nanoparticles for non-enzymatic electrochemical quantification of glucose
    Liu, Peng
    Zhang, Yuanyuan
    Ye, Lei
    Huang, Man
    Zeng, Ting
    Yang, Juan
    Tian, Fan
    Wu, Zhen
    Zhang, Xiuhua
    Hu, Chengguo
    Yang, Nianjun
    DIAMOND AND RELATED MATERIALS, 2024, 146
  • [10] Non-enzymatic glucose sensors based on metal structures produced by laser-induced deposition from solution
    Khairullina, Evgeniia M.
    Safonov, Sergey V.
    Logunov, Lev S.
    Panov, Maxim S.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (11) : 22798 - 22805