Laser-induced graphene (LIG)-based Au@CuO/V2CTx MXene non-enzymatic electrochemical sensors for the urine glucose test

被引:73
|
作者
Cui, Feiyun [1 ]
Sun, Haiming [1 ]
Yang, Xueqiong [2 ]
Zhou, Hang [2 ]
Wu, Yiqi [1 ]
Li, Jing [1 ]
Li, Hongxia [1 ]
Liu, Jianlei [3 ]
Zeng, Chijia [3 ]
Qu, Bin [4 ]
Zhang, Jufan [1 ,5 ]
Zhou, Qin [1 ]
机构
[1] Harbin Med Univ, Sch Biomed Sci, Harbin 150081, Peoples R China
[2] Chongqing Med Univ, Sch Lab Med, Key Lab Clin Diagnost, Minist Educ, Chongqing 400016, Peoples R China
[3] Foshan Fosun Chancheng Hosp, Dept Lab Med & Pathol, Foshan 528000, Guangdong, Peoples R China
[4] Saarland Univ, Ctr Integrat Physiol & Mol Med CIPMM, Sch Med, Biophys, D-66421 Homburg, Germany
[5] Univ Coll Dublin, Ctr Micro Nano Mfg Technol MNMT Dublin, Sch Mech & Mat Engn, Dublin, Ireland
关键词
Nanozyme; Laser-induced graphene (LIG); Non-enzymatic glucose electrochemical sensor; Urine glucose test; V2CTx MXene; CORE-SHELL NANOPARTICLES; PEROXIDASE-LIKE ACTIVITY; BLOOD-GLUCOSE; INSULIN; OXIDE; NANOCOMPOSITE; NANOCRYSTALS; NANOSHEETS; ACID; CU2O;
D O I
10.1016/j.cej.2023.141303
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Glucose monitoring is of great significance for the health management of diabetic patients. Herein, non-enzymatic glucose sensors were developed by modifying Au@CuO or Au@CuO/V2CTx MXene nanocomposites (NCs) on the surface of disposable laser-induced graphene (LIG) electrode. The structures and morphologies were confirmed by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and elemental analysis. The electrochemical performances of NCs were investigated by electrochemical impedance spectros-copy (EIS), cyclic voltammetry (CV) and chronoamperometry (CA). The results demonstrated that both Au@CuO/LIG and Au@CuO/V2CTx MXene/LIG have excellent electrocatalytic activity for glucose oxidation in an alkaline medium. However, it was found that Au@CuO/V2CTx MXene/LIG was easily oxidized. Hence, the combination of Au@CuO/LIG was preferred for glucose test. Under optimized conditions, the electrochemical sensor achieved a detection range of 0.005 to 5.0 mM with a sensitivity of 1.124 x 106 mu A mM-1 cm-2. The response time was 1.5 s and the limit of detection (LOD) was as low as 1.8 mu M. The sensor has good selectivity and stability (84.12 % activity retained after 6 weeks). Its affordable price, disposable usage and portable essence are suitable for clinical application. Our study presented a novel strategy to the field of non-enzymatic glucose sensing.
引用
收藏
页数:10
相关论文
共 46 条
  • [31] Fabrication of conductive Ag/AgCl/Ag nanorods ink on Laser-induced graphene electrodes on flexible substrates for non-enzymatic glucose detection
    Rana Bagheri
    Saeid Alikhani
    Ebrahim Miri-Moghaddam
    Scientific Reports, 13
  • [32] Graphene wrapped Cu2O nanocubes: Non-enzymatic electrochemical sensors for the detection of glucose and hydrogen peroxide with enhanced stability
    Liu, Minmin
    Liu, Ru
    Chen, Wei
    BIOSENSORS & BIOELECTRONICS, 2013, 45 : 206 - 212
  • [33] A vertically aligned CuO nanosheet film prepared by electrochemical conversion on Cu-based metal-organic framework for non-enzymatic glucose sensors
    Zhang, Li
    Liang, Hongbo
    Ma, Xiaoni
    Ye, Chen
    Zhao, Guangyu
    MICROCHEMICAL JOURNAL, 2019, 146 : 479 - 485
  • [34] One-pot preparation of reduced graphene oxide-carbon nanotube decorated with Au nanoparticles based on protein for non-enzymatic electrochemical sensing of glucose
    Luo, Yu
    Kong, Fen-Ying
    Li, Cheng
    Shi, Jian-Jun
    Lv, Wei-Xin
    Wang, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 625 - 632
  • [35] Dual nanocatalysts co-decorated three-dimensional, laser-induced graphene hybrid nanomaterials integrated with a smartphone portable electrochemical system for point-of-care non-enzymatic glucose diagnosis
    Huang, Yuzhen
    Han, Yingkuan
    Sun, Jiayang
    Zhang, Yu
    Han, Lin
    MATERIALS TODAY CHEMISTRY, 2022, 24
  • [36] Influence of CO2 laser beam modelling on electronic and electrochemical properties of paper-based laser-induced graphene for disposable pH electrochemical sensors
    Pinheiro, Tomas
    Rosa, Andre
    Ornelas, Cristina
    Coelho, Joao
    Fortunato, Elvira
    Marques, Ana C.
    Martins, Rodrigo
    CARBON TRENDS, 2023, 11
  • [37] NiCo2O4/Ti2NbC2 (double MXene) nanohybrid-based non-enzymatic electrochemical biosensor for the detection of glucose in sweat
    Subramania, Ashok Kumar
    Sugumaran, Sivanandam
    Sethuramalingam, Prakash
    Ramesh, Rajasekaran
    Dhandapani, Preethi
    Angaiah, Subramania
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2023, 46 (12) : 1755 - 1763
  • [38] NiCo2O4/Ti2NbC2 (double MXene) nanohybrid-based non-enzymatic electrochemical biosensor for the detection of glucose in sweat
    Ashok Kumar Subramania
    Sivanandam Sugumaran
    Prakash Sethuramalingam
    Rajasekaran Ramesh
    Preethi Dhandapani
    Subramania Angaiah
    Bioprocess and Biosystems Engineering, 2023, 46 : 1755 - 1763
  • [39] Highly sensitive electrochemical non-enzymatic glucose biosensor based on squamous NiCo2O4 nanosheets decorated nitrogen-doped reduced graphene oxide
    Wang, Changcheng
    Hu, Hongli
    Ding, Shujiang
    Dong, Min
    Li, Long
    MATERIALS TECHNOLOGY, 2022, 37 (09) : 906 - 914
  • [40] A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks
    Janmee, Nopparat
    Preechakasedkit, Pattarachaya
    Rodthongkum, Nadnudda
    Chailapakul, Orawon
    Potiyaraj, Pranut
    Ruecha, Nipapan
    ANALYTICAL METHODS, 2021, 13 (25) : 2796 - 2803