Laser-induced graphene from paper for non-enzymatic uric acid electrochemical sensing in urine

被引:38
|
作者
Kulyk, Bohdan [1 ,2 ,3 ]
Pereira, Sonia O. [1 ]
Fernandes, Antonio J. S. [1 ]
Fortunato, Elvira [2 ,3 ]
Costa, Florinda M. [1 ]
Santos, Nuno F. [1 ]
机构
[1] Univ Aveiro, Dept Phys, i3N, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] NOVA Univ Lisbon, Dept Mat Sci, i3N, CENIMAT, Campus Caparica, P-2829516 Caparica, Portugal
[3] NOVA Univ Lisbon, NOVA Sch Sci & Technol, CEMOP, UNINOVA, Campus Caparica, P-2829-516 Caparica, Portugal
关键词
Graphene; Paper-LIG; Uric acid; Human urine; Electrochemical biosensors; Flexible electronics; ASCORBIC-ACID; ELECTRON-TRANSFER; SOLUBILITY; IMPEDANCE; DOPAMINE; GRAPHITE; CARBONS; URATE; XPS;
D O I
10.1016/j.carbon.2022.06.013
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Laser-induced graphene from paper (paper-LIG) was applied in non-enzymatic electrochemical sensing of uric acid (UA) in human urine. Paper-LIG was formed by CO2 laser modification of paper into a 3D graphene arrangement. Kinetic analysis of paper-LIG electrodes returned effective heterogeneous electron transfer standard rate constants of 1.4 x 10(-3) cm s(-1) and 7.8 x 10(-4) cm s(-1) for [Ru(NH3)(6)](2+/3+) and [Fe(CN)(6)](4)(-)(/3)(-) redox probes, respectively. These electrodes were able to detect and quantify uric acid in PBS within the 10-300 mu M range at pH between 5.6 and 7.4. At pH 7.4, a linear response (R-2 = 0.999) from 10 to 250 mu M was achieved, with a limit of detection of 3.97 mu M and a sensitivity of 0.363 mu A cm(-2) mu M-1. Paper-LIG electrodes denoted adequate selectivity in synthetic urine as well as in ascorbic acid (AA) and dopamine (DA)-containing electrolytes. Determination of urinary UA content in human samples returned a concentration of c.a. 1.8-1.9 mM, within the range for healthy individuals. Recoveries of samples spiked with 50 and 100 mu M UA were 100.6% and 95.4%, respectively, with satisfactory reproducibility and stability. These cheap, lightweight, flexible, and eco-friendly paper-LIG biosensors for non-enzymatic quantification of UA in human urine pave the way to widespread application in the detection of other important biomarkers.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 50 条
  • [1] One-Step Laser Synthesis of Copper Nanoparticles and Laser-Induced Graphene in a Paper Substrate for Non-Enzymatic Glucose Sensing
    Pinheiro, Tomas
    Caetano, Joana
    Fortunato, Elvira
    Sales, M. Goreti F.
    Almeida, Henrique
    Martins, Rodrigo
    ADVANCED SENSOR RESEARCH, 2024,
  • [2] Enzymatic and Non-Enzymatic Uric Acid Electrochemical Biosensors: A Review
    Sun, Miao
    Cui, Chuanjin
    Chen, Hongshuo
    Wang, Dengling
    Zhang, Wensi
    Guo, Wenjin
    CHEMPLUSCHEM, 2023, 88 (09):
  • [3] Sustainable electrochemical sensors from cork-derived laser induced graphene: Non-enzymatic glucose detection in urine
    Setti, Michele
    Vaughan, Eoghan
    Murray, Richard
    Sygellou, Labrini
    Quinn, Aidan J.
    Riccò, Mauro
    Pontiroli, Daniele
    Iacopino, Daniela
    Sensors and Actuators B: Chemical, 2025, 430
  • [4] Laser-Induced Graphene from Paper for Mechanical Sensing
    Kulyk, Bohdan
    Silva, Beatriz F. R.
    Carvalho, Alexandre F.
    Silvestre, Sara
    Fernandes, Antonio J. S.
    Martins, Rodrigo
    Fortunato, Elvira
    Costa, Florinda M.
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (08) : 10210 - 10221
  • [5] Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate
    Johnson, Zachary T.
    Jared, Nathan
    Peterson, John K.
    Li, Jingzhe
    Smith, Emily A.
    Walper, Scott A.
    Hooe, Shelby L.
    Breger, Joyce C.
    Medintz, Igor L.
    Gomes, Carmen
    Claussen, Jonathan C.
    GLOBAL CHALLENGES, 2022, 6 (09)
  • [6] Laser-induced graphene non-enzymatic glucose sensors for on-body measurements
    Zhu, Jia
    Liu, Shangbin
    Hu, Zhihui
    Zhang, Xianzhe
    Yi, Ning
    Tang, Kairui
    Dexheimer, Michael Gregory
    Lian, Xiaojun
    Wang, Qing
    Yang, Jian
    Gray, Jennifer
    Cheng, Huanyu
    BIOSENSORS & BIOELECTRONICS, 2021, 193
  • [7] Synthesis of Laser-Induced Cobalt Oxide for Non-Enzymatic Electrochemical Glucose Sensors
    Kang, Seung-Jo
    Pak, James Jungho
    CHEMELECTROCHEM, 2022, 9 (16)
  • [8] Laser-induced graphene decorated with Ni-Pt alloy nanoparticles for non-enzymatic electrochemical quantification of glucose
    Liu, Peng
    Zhang, Yuanyuan
    Ye, Lei
    Huang, Man
    Zeng, Ting
    Yang, Juan
    Tian, Fan
    Wu, Zhen
    Zhang, Xiuhua
    Hu, Chengguo
    Yang, Nianjun
    DIAMOND AND RELATED MATERIALS, 2024, 146
  • [9] One-step laser-induced Cu-embedded graphene for non-enzymatic glucose sensing in beverages
    Zhang, Yanke
    Zhang, Chi
    Chen, Wei
    Liu, Zhengchun
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 992
  • [10] Investigating nanocatalyst-embedding laser-induced carbon nanofibers for non-enzymatic electrochemical sensing of hydrogen peroxide
    Christoph Bruckschlegel
    Marc Schlosser
    Nongnoot Wongkaew
    Analytical and Bioanalytical Chemistry, 2023, 415 : 4487 - 4499