Risk Factors of Flexor Tendon Rupture After ORIF of Distal Radius Fracture

被引:1
|
作者
Kwon, Young Woo [1 ]
Choi, In Cheul [2 ]
Kim, Myongwhan [3 ]
Nam, Jae Jun [2 ]
Park, Jong Woong [2 ,4 ]
机构
[1] Namyangju Nanum Hosp, Dept Orthoped Surg, Gyeonggi Do, South Korea
[2] Korea Univ, Coll Med, Dept Orthoped Surg, Seoul, South Korea
[3] Eulji Univ, Nowon Eulji Med Ctr, Dept Orthoped Surg, Seoul, South Korea
[4] Korea Univ, Coll Med, Dept Orthoped Surg, Anam Hosp, 73 Goryeodae ro, Seoul 02841, South Korea
关键词
distal radius fracture; flexor tendon rupture; volar plate; malreduction; plate position; POLLICIS LONGUS TENDON; VOLAR PLATE FIXATION; COMPLICATIONS;
D O I
10.1097/BOT.0000000000002498
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To analyze the risk factors associated with postoperative flexor tendon rupture, after a volar plate fixation of distal radius fractures.Design:Retrospective observational case-control study.Setting:Tertiary Care University Hospital in the Republic of Korea (2009-2020).Patients:Sixteen referred patients were treated for flexor tendon rupture, following previously performed volar plating of distal radius fractures at other institutions. 16 patients were randomly selected from our database as controls, and were matched based on the Soong grade of the case group.Intervention:Not applicable.Main Outcome Measurements:Radial tilt and radial height were measured on anteroposterior radiographs. The volar tilt, tear drop angle, carpal translation, and Soong grade were measured in a lateral view.Results:Quantitative measurements of the volar tilt, carpal translation, and tear drop angle were positively correlated with the flexor tendon rupture. The mean volar tilt and tear drop angle in the tendon rupture group were significantly smaller than those in the control group. The mean carpal translation in the tendon rupture group was significantly greater than that in the control group.Conclusions:This study demonstrated that volar tilt, carpal translation, and tear drop angle are significant risk factors for flexor tendon rupture, especially for plates placed at Soong grade 1 or 2. We suggest that the potential for tendon rupture because of incomplete reduction of the distal radius fracture along with implant prominence volar to the watershed line aggravates flexor tendon irritation at the distal edge of the plate because of distorted flexor tendon paths.
引用
收藏
页码:E99 / E103
页数:5
相关论文
共 50 条
  • [31] The risk factors for subsequent fractures after distal radius fracture
    Lim, Eic Ju
    Lee, Sunhyung
    Kim, Jae Kwang
    Kim, Huijeong
    Shin, Young Ho
    JOURNAL OF BONE AND MINERAL METABOLISM, 2022, 40 (05) : 853 - 859
  • [32] Late rupture of Flexor Pollicis Longus tendon 10 years after volar buttress plate fixation of a distal radius fracture : A case report
    Monda, Maureen K.
    Ellis, Allun
    Karmani, Shuaib
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (04): : 549 - 551
  • [33] Incidence and Clinical Outcomes of Tendon Rupture Following Distal Radius Fracture
    White, Brian D.
    Nydick, Jason A.
    Karsky, Dawnne
    Williams, Bailee D.
    Hess, Alfred V.
    Stone, Jeffrey D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (10): : 2035 - 2040
  • [34] Rupture of Flexor Pollicis Longus Tendon: A Complication of Volar Locking Plating of the Distal Radius
    Rajeev, Aysha Sethunathan
    Sreverthana, Shanaka
    Harrison, John
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2010, 36 (04) : 385 - 387
  • [35] Rupture of Flexor Pollicis Longus Tendon: A Complication of Volar Locking Plating of the Distal Radius
    Aysha Sethunathan Rajeev
    Shanaka Sreverthana
    John Harrison
    European Journal of Trauma and Emergency Surgery, 2010, 36 : 385 - 387
  • [36] ATTRITION RUPTURE OF FLEXOR TENDONS AT THE WRIST FOLLOWING EPIPHYSEAL FRACTURE OF THE DISTAL RADIUS
    SANTANA, DR
    DELISS, L
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (05): : 585 - 587
  • [37] Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the π plate on the volar surface of the distal radius
    Nunley, JA
    Rowan, PR
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (06): : 1279 - 1280
  • [38] Rupture of the flexor tendons through inadequate reposition and retention after operative treatment of a distal fracture of the radius
    Stocker, R.
    Maier, R.
    UNFALLCHIRURG, 2007, 110 (11): : 1001 - 1002
  • [39] Entrapment of the median nerve and flexor pollicis longus tendon after a high-energy fracture of the distal radius
    Halsey, T.
    Grieve, A.
    Jones, J. W. M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (05) : 421 - 423
  • [40] Ultrasonographic movement of the flexor pollicis longus tendon before and after removal of a volar plate for the distal radius fracture
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (01):