Risk Factors of Flexor Tendon Rupture After ORIF of Distal Radius Fracture

被引:1
|
作者
Kwon, Young Woo [1 ]
Choi, In Cheul [2 ]
Kim, Myongwhan [3 ]
Nam, Jae Jun [2 ]
Park, Jong Woong [2 ,4 ]
机构
[1] Namyangju Nanum Hosp, Dept Orthoped Surg, Gyeonggi Do, South Korea
[2] Korea Univ, Coll Med, Dept Orthoped Surg, Seoul, South Korea
[3] Eulji Univ, Nowon Eulji Med Ctr, Dept Orthoped Surg, Seoul, South Korea
[4] Korea Univ, Coll Med, Dept Orthoped Surg, Anam Hosp, 73 Goryeodae ro, Seoul 02841, South Korea
关键词
distal radius fracture; flexor tendon rupture; volar plate; malreduction; plate position; POLLICIS LONGUS TENDON; VOLAR PLATE FIXATION; COMPLICATIONS;
D O I
10.1097/BOT.0000000000002498
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To analyze the risk factors associated with postoperative flexor tendon rupture, after a volar plate fixation of distal radius fractures.Design:Retrospective observational case-control study.Setting:Tertiary Care University Hospital in the Republic of Korea (2009-2020).Patients:Sixteen referred patients were treated for flexor tendon rupture, following previously performed volar plating of distal radius fractures at other institutions. 16 patients were randomly selected from our database as controls, and were matched based on the Soong grade of the case group.Intervention:Not applicable.Main Outcome Measurements:Radial tilt and radial height were measured on anteroposterior radiographs. The volar tilt, tear drop angle, carpal translation, and Soong grade were measured in a lateral view.Results:Quantitative measurements of the volar tilt, carpal translation, and tear drop angle were positively correlated with the flexor tendon rupture. The mean volar tilt and tear drop angle in the tendon rupture group were significantly smaller than those in the control group. The mean carpal translation in the tendon rupture group was significantly greater than that in the control group.Conclusions:This study demonstrated that volar tilt, carpal translation, and tear drop angle are significant risk factors for flexor tendon rupture, especially for plates placed at Soong grade 1 or 2. We suggest that the potential for tendon rupture because of incomplete reduction of the distal radius fracture along with implant prominence volar to the watershed line aggravates flexor tendon irritation at the distal edge of the plate because of distorted flexor tendon paths.
引用
收藏
页码:E99 / E103
页数:5
相关论文
共 50 条
  • [21] Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius
    Bell, JSP
    Wollstein, R
    Citron, ND
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 225 - 226
  • [22] Rupture of the flexor tendon after malunited Colles' fracture
    Murase, T
    Hiroshima, K
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2003, 37 (03): : 188 - 191
  • [23] Pronator Quadratus Muscle Flap for Prevention of Flexor Tendon Rupture after Distal Radius Volar Plating
    Husain, Tarik M.
    Jabbour, Jacob I.
    Sudduth, Jack D.
    Lessard, Anne-Sophie
    Patete, Carissa L.
    Panthaki, Zubin J.
    Salloum, Gabe E.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2023, 11 (08) : E5227
  • [24] PREVENTION OF FLEXOR POLLICIS LONGUS TENDON RUPTURE AFTER VOLAR PLATE FIXATION OF DISTAL RADIUS FRACTURES
    Tada, Kaoru
    Ikeda, Kazuo
    Shigemoto, Kenji
    Suganuma, Seigo
    Tsuchiya, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2011, 16 (03): : 271 - 275
  • [25] Risk for Flexor Pollicis Longus Rupture after Volar Lock Plating for Distal Radius Fracture Lasts Over a Decade
    H.Nordback, Panu
    Lee, Ellen Y.
    Lim, Jin Xi
    Lim, Aymeric Y. T.
    Das De, Soumen
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (12): : 835 - 839
  • [26] Comminuted fracture of the distal sesamoid bone and distal rupture of the deep digital flexor tendon
    Hoegaerts, M
    Pille, F
    De Clercq, T
    Fulton, JC
    Saunders, JH
    VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (03) : 234 - 237
  • [27] Extensor pollicis longus tendon rupture with concomitant rupture of the extensor digitorum communis II tendon after distal radius fracture
    de Boer, S. W.
    van Kooten, E. O.
    Ritt, M. J. P. F.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (08) : 679 - 681
  • [28] Haemorrhage in the sheath of Extensor Pollicis Longus tendon after distal radius fracture: Implications for pathogenesis of tendon rupture?
    Oliver, A.
    Hems, T. E. J.
    SCOTTISH MEDICAL JOURNAL, 2008, 53 (02) : 60 - 60
  • [29] RISK FACTORS FOR SUBSEQUENT FRACTURES AFTER DISTAL RADIUS FRACTURE
    Ahn, J. H.
    Lim, E. J.
    Lee, S. H.
    Kim, J. K.
    Kim, H. J.
    Shin, Y. H.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2024, 36 : S331 - S331
  • [30] The risk factors for subsequent fractures after distal radius fracture
    Eic Ju Lim
    Sunhyung Lee
    Jae Kwang Kim
    Huijeong Kim
    Young Ho Shin