AAV analysis by sedimentation velocity analytical ultracentrifugation: beyond empty and full capsids

被引:13
|
作者
Yarawsky, Alexander E. [1 ]
Zai-Rose, Valeria [1 ]
Cunningham, Hazel M. [1 ]
Burgner II, John W. [1 ,2 ]
DeLion, Michael T. [1 ]
Paul, Lake N. [1 ]
机构
[1] BioAnalysis LLC, 3401 1 St Suite 206, Philadelphia, PA 19134 USA
[2] Virginia Commonwealth Univ, Sch Pharm, Dept Med Chem, 800 East Leigh St, Richmond, VA 23298 USA
关键词
Adeno-associated viral vectors; cGMP; SEDFIT; Wide distribution analysis; Time derivative; Partial capsids; COEFFICIENT DISTRIBUTION; SIZE-DISTRIBUTION; DISTRIBUTIONS; MACROMOLECULES; QUANTIFICATION; SEPARATION;
D O I
10.1007/s00249-023-01646-z
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The recent surge of therapeutic interest in recombinant adeno-associated viral (AAV) vectors for targeted DNA delivery has brought analytical ultracentrifugation (AUC) into the spotlight. A major concern during formulation of AAV therapeutics is purity of the active species (DNA-containing capsid, or "filled capsids"). Insertion of DNA into AAV is not a highly efficient process; thus, a significant amount of empty and partial/intermediate AAV molecules may exist. Recent guidance from the FDA includes limiting the presence of empty AAV capsids and other impurities to reduce immunotoxicity. While chromatographic techniques (SEC, SEC-MALS, AEX) are often used for empty and full capsid quantitation due to the ease of accessibility and familiarity among most biochemists, the resolution and sensitivity attained by sedimentation velocity (SV-AUC) in the formulation buffer and purification buffers is unmatched. Approaches for using SV-AUC to determine the empty-to-full capsid ratio have already been discussed by others; however, in this report, we focus on the importance of characterizing other impurities, such as free DNA, partially filled capsids, and aggregates that are recognized as species of concern for immunotoxicity. We also demonstrate the usefulness of applying multiple analyses (e.g., c(s), g(s*), WDA) in confirming the presence of and determining the hydrodynamic parameters of these various species.
引用
收藏
页码:353 / 366
页数:14
相关论文
共 50 条
  • [21] Separation of Empty Capsids from Full Capsids for AAV Gene Therapy Using a Flow through and Step Elution Approach
    Arunkumar, Abhiram
    Singh, Nripen
    MOLECULAR THERAPY, 2021, 29 (04) : 119 - 119
  • [22] AAV Full to Empty Ratio Study, Comparison of Analytical Techniques
    Leeser, Owen
    Begley, Darren W.
    Foster, Dave
    Haq, Daniel
    MOLECULAR THERAPY, 2024, 32 (04) : 465 - 465
  • [23] Flotation Coefficient Distributions of Lipid Nanoparticles by Sedimentation Velocity Analytical Ultracentrifugation
    Zhao, Huaying
    Sousa, Alioscka A.
    Schuck, Peter
    ACS NANO, 2024, 18 (28) : 18663 - 18672
  • [24] Macromolecular size-and-shape distributions by sedimentation velocity analytical ultracentrifugation
    Brown, Patrick H.
    Schuck, Peter
    BIOPHYSICAL JOURNAL, 2006, 90 (12) : 4651 - 4661
  • [25] Strategies to Improve Data Quality and Maximize Throughput of Sedimentation Velocity Analytical Ultracentrifugation Experiments to Characterize AAV Gene Therapy Products
    Bhatt, Vinay
    MOLECULAR THERAPY, 2020, 28 (04) : 550 - 550
  • [26] Identification of aggregates in therapeutic formulations of recombinant full-length factor VIII products by sedimentation velocity analytical ultracentrifugation
    Healey, J. F.
    Parker, E. T.
    Lollar, P.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2018, 16 (02) : 303 - 315
  • [27] Analytical band centrifugation for the separation and quantification of empty and full AAV particles
    Khasa, Harshit
    Kilby, Greg
    Chen, Xiaoyu
    Wang, Chunlei
    MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2021, 21 : 585 - 591
  • [28] Variable Field Analytical Ultracentrifugation: II. Gravitational Sweep Sedimentation Velocity
    Ma, Jia
    Zhao, Huaying
    Sandmaier, Julia
    Liddle, J. Alexander
    Schuck, Peter
    BIOPHYSICAL JOURNAL, 2016, 110 (01) : 103 - 112
  • [29] Best Practices for Aggregate Quantitation of Antibody Therapeutics by Sedimentation Velocity Analytical Ultracentrifugation
    Bou-Assaf, George M.
    Budyak, Ivan L.
    Brenowitz, Michael
    Day, Eric S.
    Hayes, David
    Hill, John
    Majumdar, Ranajoy
    Ringhieri, Paola
    Schuck, Peter
    Lin, Jasper C.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 111 (07) : 2121 - 2133
  • [30] Precision of protein aggregation measurements by sedimentation velocity analytical ultracentrifugation in biopharmaceutical applications
    Gabrielson, John P.
    Arthur, Kelly K.
    Stoner, Michael R.
    Winn, Bradley C.
    Kendrick, Brent S.
    Razinkov, Vladimir
    Svitel, Juraj
    Jiang, Yijia
    Voelker, Paul J.
    Fernandes, Cledwyn A.
    Ridgeway, Ron
    ANALYTICAL BIOCHEMISTRY, 2010, 396 (02) : 231 - 241