Identification of aggregates in therapeutic formulations of recombinant full-length factor VIII products by sedimentation velocity analytical ultracentrifugation

被引:11
|
作者
Healey, J. F. [1 ]
Parker, E. T. [1 ]
Lollar, P. [1 ]
机构
[1] Emory Univ, Childrens Healthcare Atlanta, Aflac Canc & Blood Disorders Ctr, Dept Pediat, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
aggregates; analytical ultracentrifugation; factor VIII; hemophilia A; immunogenicity; SEVERE HEMOPHILIA-A; PREVIOUSLY UNTREATED PATIENTS; VON-WILLEBRAND-FACTOR; HUMAN GAMMA-GLOBULIN; INHIBITOR DEVELOPMENT; IMMUNE-RESPONSES; RISK-FACTORS; PROTEIN; IMMUNOGENICITY; RODIN;
D O I
10.1111/jth.13917
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The development of inhibitory anti-factor VIII antibodies is the most serious complication in the management of patients with hemophilia A. Studies have suggested that recombinant full-length FVIII is more immunogenic than plasma-derived FVIII, and that, among recombinant FVIII products, Kogenate is more immunogenic than Advate. Aggregates in biopharmaceutical products are considered a risk factor for the development of anti-drug antibodies. Objective: To evaluate recombinant full-length FVIII products for the presence of aggregates. Methods: Advate, Helixate and Kogenate were reconstituted to their therapeutic formulations, and subjected to sedimentation velocity (SV) analytical ultracentrifugation (AUC). Additionally, Advate and Kogenate were concentrated and subjected to buffer exchange by ultrafiltration to remove viscous cosolvents for the purpose of measuring s(20), (w) values and molecular weights. Results: The major component of all three products was a population of similar to 7.5 S heterodimers with a weight-average molecular weight of similar to 230 kDa. Helixate and Kogenate contained aggregates ranging from 12 S to at least 100 S, representing approximate to 20% of the protein mass. Aggregates greater than 12 S represented < 3% of the protein mass in Advate. An approximately 10.5 S aggregate, possibly representing a dimer of heterodimers, was identified in buffer-exchanged Advate and Kogenate. SV AUC analysis of a plasma-derived FVIII product was confounded by the presence of von Willebrand factor in molar excess over FVIII. Conclusions: Aggregate formation has been identified in recombinant full-length FVIII products, and is more extensive in Helixate and Kogenate than in Advate. SV AUC is an important method for characterizing FVIII products.
引用
收藏
页码:303 / 315
页数:13
相关论文
共 50 条
  • [1] Sedimentation Velocity Analytical Ultracentrifugation of Oxidized Recombinant Full-Length Factor VIII
    Zakas, Philip M.
    Healey, John F.
    Smith, Ian W.
    Lillicrap, David
    Lollar, Pete
    FRONTIERS IN IMMUNOLOGY, 2020, 11
  • [2] Full-length recombinant factor VIII (FL-RFVIII): is it safer?
    Aledort, L. M.
    Navickis, R. J.
    Wilkes, M. M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 372 - 372
  • [3] Defining 'full-length' recombinant factor VIII: a comparative structural analysis
    Jankowski, M. A.
    Patel, H.
    Rouse, J. C.
    Marzilli, L. A.
    Weston, S. B.
    Sharpe, P. J.
    HAEMOPHILIA, 2007, 13 (01) : 30 - 37
  • [4] Pharmacokinetic properties of BAY 81-8973, a full-length recombinant factor VIII
    Shah, A.
    Delesen, H.
    Garger, S.
    Lalezari, S.
    HAEMOPHILIA, 2015, 21 (06) : 766 - 771
  • [5] Quantitation of aggregates in therapeutic proteins using sedimentation velocity analytical ultracentrifugation: Practical considerations that affect precision and accuracy
    Pekar, Allen
    Sukumar, Muppalla
    ANALYTICAL BIOCHEMISTRY, 2007, 367 (02) : 225 - 237
  • [6] Pegylated, full-length, recombinant factor VIII for prophylactic and on-demand treatment of severe hemophilia A
    Konkle, Barbara A.
    Stasyshyn, Oleksandra
    Chowdary, Pratima
    Bevan, David H.
    Mant, Tim
    Shima, Midori
    Engl, Werner
    Dyck-Jones, Jacqueline
    Fuerlinger, Monika
    Patrone, Lisa
    Ewenstein, Bruce
    Abbuehl, Brigitt
    BLOOD, 2015, 126 (09) : 1078 - 1085
  • [7] BAY 81-8973, a full-length recombinant factor VIII: manufacturing processes and product characteristics
    Garger, S.
    Severs, J.
    Regan, L.
    Hesslein, A.
    Ignowski, J.
    Wu, P.
    Long, E.
    Gupta, S.
    Liu, S.
    Wang, W.
    HAEMOPHILIA, 2017, 23 (02) : E67 - E78
  • [8] BAY 81-8973, a full-length recombinant factor VIII for the treatment of hemophilia A: product review
    Mahlangu, Johnny N.
    Ahuja, Sanjay P.
    Windyga, Jerzy
    Church, Nikki
    Shah, Anita
    Schwartz, Lawrence
    THERAPEUTIC ADVANCES IN HEMATOLOGY, 2018, 9 (07) : 191 - 205
  • [9] Safety of BAX 855, a polyethylene glycol (PEG) conjugated full-length recombinant Factor VIII product
    Stidl, Reinhard
    Dietrich, Barbara
    Spatzenegger, Margit
    Muchitsch, Eva-Maria
    Bossard, Mary
    Scheiflinger, Friedrich
    Turecek, Peter L.
    HAEMOPHILIA, 2014, 20 : 24 - 24
  • [10] Safety of BAX 855, a polyethylene glycol (PEG) conjugated full-length recombinant factor VIII product
    Muchitsch, E.
    Dietrich, B.
    Spatzenegger, M.
    Stidl, R.
    Vinson, T.
    Shen, X.
    Bossard, M.
    Rottensteiner, H.
    Scheiflinger, F.
    Ehrlich, H.
    Turecek, P.
    HAEMOPHILIA, 2012, 18 : 39 - 39