Whole Brain Micro-Vascular Imaging Using Robot Assisted Optical Coherence Tomography Angiography

被引:12
|
作者
He, Bin [1 ,2 ,3 ]
Zhang, Yuxin [4 ]
Meng, Zhe [3 ,5 ,6 ]
He, Zhijun [3 ,5 ,6 ]
Chen, Zhenyu [1 ,2 ]
Yin, Zichen
Hu, Zhangwei [1 ,2 ]
Shi, Yejiong [1 ,2 ]
Wang, Chengming [7 ]
Zhang, Xiao [8 ]
Zhang, Ning [9 ]
Wang, Guihuai [5 ,6 ]
Xue, Ping [1 ,2 ]
机构
[1] Tsinghua Univ, State Key Lab Low dimensional Quantum Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Collaborat Innovat Ctr Quantum Matter, Dept Phys, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Beijing Adv Innovat Ctr Struct Biol, Beijing 100084, Peoples R China
[4] Imperial Coll London, Dept Mat, London SW7 2AZ, England
[5] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Neurosurg, Beijing 102218, Peoples R China
[6] Tsinghua Univ, Inst Precis Med, Beijing 102218, Peoples R China
[7] Nuctech Co Ltd, Beijing 100084, Peoples R China
[8] Beijing Inst Technol, Beijing 100081, Peoples R China
[9] Minist Publ Secur, Inst Forens Sci, Beijing 100055, Peoples R China
基金
中国国家自然科学基金;
关键词
Manipulators; Imaging; Robot kinematics; Calibration; Needles; Probes; Flanges; Optical coherence tomography angiography; Robotic arm; High resolution; large field; Full brain; WIDE-FIELD; CALIBRATION;
D O I
10.1109/JSTQE.2022.3229659
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of similar to 60 mu m. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm x 8.1 mm x 1 mm with a resolution of similar to 4 mu m(axial) x similar to 6 mu m(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Importance of Optical Coherence Tomography and Optical Coherence Tomography Angiography in the Imaging and Differentiation of Choroidal Melanoma: A Review
    Obuchowska, Iwona
    Konopinska, Joanna
    CANCERS, 2022, 14 (14)
  • [42] Optical coherence tomography for whole eye segment imaging
    Dai, Cuixia
    Zhou, Chuanqing
    Fan, Shanhui
    Chen, Zhe
    Chai, Xinyu
    Ren, Qiushi
    Jiao, Shuliang
    OPTICS EXPRESS, 2012, 20 (06): : 6109 - 6115
  • [43] Foveal vascular development in pediatric eyes assessed using optical coherence tomography angiography
    Hsu, S. Tammy
    Hoan Ngo
    House, Robert
    Tian, James
    Finn, Avni
    Cheung, Nathan
    Kelly, Michael P.
    Freedman, Sharon
    Toth, Cynthia A.
    Vajzovic, Lejla
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [44] Investigation of Retinal Vascular Changes during Pregnancy Using Optical Coherence Tomography Angiography
    Hepokur, Mustafa
    Gonen, Busenur
    Hamzaoglu, Kubra
    Tuten, Abdullah
    Sarici, Ahmet Murat
    SEMINARS IN OPHTHALMOLOGY, 2021, 36 (1-2) : 19 - 27
  • [45] Retinal vascular response to dark adaptation using a functional optical coherence tomography angiography
    Adhikari, Suman
    Shi, Yaping
    Zhou, Xiao
    Wang, Ruikang
    Kashani, Amir
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [46] Retinal vascular density evaluated using Optical Coherence Tomography Angiography - a novel technique
    Chay, Isaac
    Tan, Colin S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [47] Macular vascular density at the superficial capillary plexus using the optical coherence tomography angiography
    Hashmani, Nauman
    Hashmani, Sharif
    Murad, Asif
    Baig, Natasha
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 295 - 302
  • [48] Clinical evaluation of vascular lesions in diabetic retinopathy using optical coherence tomography angiography
    Ishibazawa, Akihiro
    Nagaoka, Taiji
    Takahashi, Atsushi
    Omae, Tsuneaki
    Tani, Tomofumi
    Sogawa, Kenji
    Yokota, Harumasa
    Yoshida, Akitoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [49] Evaluation of retinal vascular parameters in bipolar disorder using optical coherence tomography angiography
    Tekdemir, Rukiye
    Oflaz, Ayse Bozkurt
    Cinar, Furkan
    Ugur, Mustafa Tugrul
    Karakucuk, Yalcin
    Altinbas, Kursat
    JOURNAL OF AFFECTIVE DISORDERS, 2025, 377 : 85 - 91
  • [50] Image Quality and Retinal Vascular Metrics in the Community using Optical Coherence Tomography Angiography
    Kherani, Saleema A.
    Guo, Xinxing
    Arsiwala, Lubaina
    Dong, Yanan
    Kong, Xiangrong
    Sharrett, A. Richey
    Ramulu, Pradeep Y.
    Huang, David
    Lujan, Brandon J.
    Tomlinson, Alexander
    Abraham, Alison
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)