Whole Brain Micro-Vascular Imaging Using Robot Assisted Optical Coherence Tomography Angiography

被引:12
|
作者
He, Bin [1 ,2 ,3 ]
Zhang, Yuxin [4 ]
Meng, Zhe [3 ,5 ,6 ]
He, Zhijun [3 ,5 ,6 ]
Chen, Zhenyu [1 ,2 ]
Yin, Zichen
Hu, Zhangwei [1 ,2 ]
Shi, Yejiong [1 ,2 ]
Wang, Chengming [7 ]
Zhang, Xiao [8 ]
Zhang, Ning [9 ]
Wang, Guihuai [5 ,6 ]
Xue, Ping [1 ,2 ]
机构
[1] Tsinghua Univ, State Key Lab Low dimensional Quantum Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Collaborat Innovat Ctr Quantum Matter, Dept Phys, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Beijing Adv Innovat Ctr Struct Biol, Beijing 100084, Peoples R China
[4] Imperial Coll London, Dept Mat, London SW7 2AZ, England
[5] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Neurosurg, Beijing 102218, Peoples R China
[6] Tsinghua Univ, Inst Precis Med, Beijing 102218, Peoples R China
[7] Nuctech Co Ltd, Beijing 100084, Peoples R China
[8] Beijing Inst Technol, Beijing 100081, Peoples R China
[9] Minist Publ Secur, Inst Forens Sci, Beijing 100055, Peoples R China
基金
中国国家自然科学基金;
关键词
Manipulators; Imaging; Robot kinematics; Calibration; Needles; Probes; Flanges; Optical coherence tomography angiography; Robotic arm; High resolution; large field; Full brain; WIDE-FIELD; CALIBRATION;
D O I
10.1109/JSTQE.2022.3229659
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of similar to 60 mu m. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm x 8.1 mm x 1 mm with a resolution of similar to 4 mu m(axial) x similar to 6 mu m(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Optical Coherence Tomography Angiography for Iris Vasculature Imaging
    Lobos, Claudio Zett
    Rosa Stina, Deborah M.
    Kato, Renata
    Novais, Eduardo Amorim
    Allemann, Norma
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [32] Optical coherence tomography angiography and photoacoustic imaging in dermatology
    Mengyang Liu
    Wolfgang Drexler
    Photochemical & Photobiological Sciences, 2019, 18 : 945 - 962
  • [33] THE RELATIONSHIPS BETWEEN PLAQUE VULNERABILITY IDENTIFIED BY OPTICAL COHERENCE TOMOGRAPHY AND MICRO-VASCULAR DYSFUNCTION AFTER STENT IMPLANTATION
    Osue, Tsuyoshi
    Shinke, Toshiro
    Otake, Hiromasa
    Nakagawa, Masayuki
    Hariki, Hirotoshi
    Inoue, Takumi
    Taniguchi, Yu
    Iwasaki, Masamichi
    Konishi, Akihide
    Kinutani, Hiroto
    Nishio, Ryo
    Kuroda, Masaru
    Hirata, Ken-Ichi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1787 - E1787
  • [34] Imaging of Corneal Neovascularization: Optical Coherence Tomography Angiography and Fluorescence Angiography
    Brunner, Matthias
    Romano, Vito
    Steger, Bernhard
    Vinciguerra, Riccardo
    Lawman, Samuel
    Williams, Bryan
    Hicks, Nicholas
    Czanner, Gabriela
    Zheng, Yalin
    Willoughby, Colin E.
    Kaye, Stephen B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (03) : 1263 - 1269
  • [35] Optic Nerve Head Drusen: Imaging Using Optical Coherence Tomography Angiography
    Flores-Reyes, Elsa
    Hoskens, Kirsten
    Mansouri, Kaweh
    JOURNAL OF GLAUCOMA, 2017, 26 (09) : 845 - 849
  • [36] Capillary velocity measurement using microsphere imaging in optical coherence tomography angiography
    Yu, Huanhuan
    Zhang, Changlu
    Kong, Ruiming
    Lv, Fukang
    Ma, Teng
    Dai, Cuixia
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XIII, 2023, 12770
  • [37] Retinal Vascular Layers Imaged by Fluorescein Angiography and Optical Coherence Tomography Angiography
    Spaide, Richard F.
    Klancnik, James M., Jr.
    Cooney, Michael J.
    JAMA OPHTHALMOLOGY, 2015, 133 (01) : 45 - 50
  • [38] The role of optical coherence tomography angiography in fundus vascular abnormalities
    Yu, Shanshan
    Lu, Jing
    Cao, Di
    Liu, Ruyuan
    Liu, Bingqian
    Li, Tao
    Luo, Yan
    Lu, Lin
    BMC OPHTHALMOLOGY, 2016, 16
  • [39] Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
    Kushner-Lenhoff, Sam
    Ashimatey, Bright S.
    Kashani, Amir H.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (157):
  • [40] The role of optical coherence tomography angiography in fundus vascular abnormalities
    Shanshan Yu
    Jing Lu
    Di Cao
    Ruyuan Liu
    Bingqian Liu
    Tao Li
    Yan Luo
    Lin Lu
    BMC Ophthalmology, 16