Significance of sources and size distribution on calibration of low-cost particle sensors: Evidence from a field sampling campaign

被引:12
|
作者
Malyan, Vasudev [1 ]
Kumar, Vikas [2 ]
Sahu, Manoranjan [1 ,2 ,3 ,4 ]
机构
[1] Indian Inst Technol, Environm Sci & Engn Dept, Aerosol & Nanoparticle Technol Lab, Mumbai 400076, India
[2] Indian Inst Technol, Interdisciplinary Program Climate Studies, Mumbai 400076, India
[3] Indian Inst Technol, Ctr Machine Intelligence & Data Sci, Mumbai 400076, India
[4] Indian Inst Technol, Environm Sci & Engn Dept, Aerosol & Nanoparticle Technol Lab, 507, Mumbai 400076, India
关键词
Low-cost sensor; Particle size distribution; Machine learning; Calibration; PARTICULATE MATTER; LABORATORY EVALUATION; AIR-QUALITY; AMBIENT; PM2.5; NETWORK; COARSE; EMISSIONS; OPC-N2;
D O I
10.1016/j.jaerosci.2022.106114
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Low-cost sensors (LCS) are gathering the interest of researchers and monitoring agencies worldwide due to their compact size and economic feasibility. However, the data recorded by LCS is often of low quality owing to its calibration dependencies and biases. An intensive field sam-pling campaign was conducted at five sites inside the IIT Bombay campus to understand the fundamental issues associated with LCS. PA-II and OPC-N2 LCS were collocated with BAM-1020 and OPS-3330 at the sampling locations for inter-comparison. LCS shows a good correlation with BAM-1020 at sites where the contributing sources produce more particles in the 1-2.5 mu m size range than particles in below 1 mu m (PM1) and 2.5-10 mu m size range. The performance decreased with an increase in mass fractions of PM1 and PM10. The overall performance of both PA-II (R2 = 0.72) and OPC-N2 (R2 = 0.73) are comparable. Both PA-II and OPC-N2 have substandard per-formance with R2 in the range of 0.30-0.39 and 0.42-0.53 at the construction and main gate site respectively. Comparing the two calibration approaches used in this study indicates the impor-tance of including size distribution parameters in the calibration of LCS. The calibration models were developed for each site and were compared with the general model developed for PA-II and OPC-N2. Results indicate that the site-specific models are in better agreement with the reference instrument than the general calibration model. The number concentration recorded by PA-II was poorly correlated with OPS-3330, especially for particles >1 mu m and vice versa for OPC-N2. The particle count for PM > 2.5 mu m recorded by PA-II is predominantly zero, which is inconsistent with the mass concentration data recorded by the sensor. The size distribution results indicate that LCS assumes a universal monotonically decreasing function of number concentration with respect to the particle diameter. It is one of the critical problems with LCS measurements as any error in the number measurement is increased 3-fold in the mass conversion. This study shows the need for site-specific robust calibration of LCS based on the particle size distribution and provides a direction in their development.
引用
下载
收藏
页数:14
相关论文
共 45 条
  • [31] Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
    Casey, Joanna Gordon
    Hannigan, Michael P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (11) : 6351 - 6378
  • [32] Citizen-operated mobile low-cost sensors for urban PM2.5 monitoring: field calibration, uncertainty estimation, and application
    Hassani, Amirhossein
    Castell, Nuria
    Watne, Agot K.
    Schneider, Philipp
    SUSTAINABLE CITIES AND SOCIETY, 2023, 95
  • [33] Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
    Huang, Ching-Hsuan
    He, Jiayang
    Austin, Elena
    Seto, Edmund
    Novosselov, Igor
    PLOS ONE, 2021, 16 (11):
  • [34] Improved PM2.5 concentration estimates from low-cost sensors using calibration models categorized by relative humidity
    Hua, Jinxi
    Zhang, Yuanxun
    de Foy, Benjamin
    Mei, Xiaodong
    Shang, Jing
    Zhang, Yang
    Sulaymon, Ishaq Dimeji
    Zhou, Dandan
    AEROSOL SCIENCE AND TECHNOLOGY, 2021, 55 (05) : 600 - 613
  • [35] Low-Cost Air Quality Sensors: One-Year Field Comparative Measurement of Different Gas Sensors and Particle Counters with Reference Monitors at Tusimice Observatory
    Bauerova, Petra
    Sindelarova, Adriana
    Rychlik, Stepan
    Novak, Zbynek
    Keder, Josef
    ATMOSPHERE, 2020, 11 (05)
  • [36] A simple, low-cost and rapid contrasting method for screening the particle size and monodispersity of silica microparticles by optical bright field microscopy
    Schetter, Bernd
    Fischer, Gerd
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2007, 44 (02) : 167 - 170
  • [37] A simple, low-cost and rapid contrasting method for screening the particle size and monodispersity of silica microparticles by optical bright field microscopy
    Bernd Schetter
    Gerd Fischer
    Journal of Sol-Gel Science and Technology, 2007, 44 : 167 - 170
  • [38] Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring. Part B: NO, CO and CO2
    Spinelle, Laurent
    Gerboles, Michel
    Villani, Maria Gabriella
    Aleixandre, Manuel
    Bonavitacola, Fausto
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 706 - 715
  • [39] In search of an optimal in-field calibration method of low-cost gas sensors for ambient air pollutants: Comparison of linear, multilinear and artificial neural network approaches
    Topalovic, Dusan B.
    Davidovic, Milos D.
    Jovanovic, Maja
    Bartonova, Alena
    Ristovski, Zoran
    Jovasevic-Stojanovic, Milena
    ATMOSPHERIC ENVIRONMENT, 2019, 213 : 640 - 658
  • [40] Using Step Size and Lower Limb Segment Orientation from Multiple Low-Cost Wearable Inertial/Magnetic Sensors for Pedestrian Navigation
    Tjhai, Chandra
    O'Keefe, Kyle
    SENSORS, 2019, 19 (14)