Low-Cost Air Quality Sensors: One-Year Field Comparative Measurement of Different Gas Sensors and Particle Counters with Reference Monitors at Tusimice Observatory

被引:27
|
作者
Bauerova, Petra [1 ]
Sindelarova, Adriana [1 ]
Rychlik, Stepan [2 ]
Novak, Zbynek [3 ]
Keder, Josef [1 ]
机构
[1] Czech Hydrometeorol Inst, Tusimice Observ, Tusimice 6, Kadan 43201, Czech Republic
[2] Czech Hydrometeorol Inst, Cent Ambient Air Qual Labs, Generala Sisky 942, Prague 14200, Czech Republic
[3] Envitech Bohemia Sro, Ovocna 34-1021, Prague 16100, Czech Republic
关键词
microsensors; particle counter; gas analyzers; relative humidity; air pollution; AVAILABLE SENSORS; CALIBRATION; POLLUTION; CLUSTER;
D O I
10.3390/atmos11050492
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With attention increasing regarding the level of air pollution in different metropolitan and industrial areas worldwide, interest in expanding the monitoring networks by low-cost air quality sensors is also increasing. Although the role of these small and affordable sensors is rather supplementary, determination of the measurement uncertainty is one of the main questions of their applicability because there is no certificate for quality assurance of these non-reference technologies. This paper presents the results of almost one-year field testing measurements, when the data from different low-cost sensors (for SO2, NO2, O-3, and CO: Cairclip, Envea, FR; for PM1, PM2.5, and PM10: PMS7003, Plantower, CHN, and OPC-N2, Alphasense, UK) were compared with co-located reference monitors used within the Czech national ambient air quality monitoring network. The results showed that in addition to the given reduced measurement accuracy of the sensors, the data quality depends on the early detection of defective units and changes caused by the effect of meteorological conditions (effect of air temperature and humidity on gas sensors and effect of air humidity with condensation conditions on particle counters), or by the interference of different pollutants (especially in gas sensors). Comparative measurement is necessary prior to each sensor's field applications.
引用
收藏
页数:15
相关论文
共 38 条
  • [1] Calibration of Low-cost Gas Sensors for Air Quality Monitoring
    Margaritis, Dimitris
    Keramydas, Christos
    Papachristos, Ioannis
    Lambropoulou, Dimitra
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (11)
  • [2] Deployment of low-cost air quality sensors in Rouen: A dataset of one year of hourly concentrations of gas pollutants
    Thulliez, Emma
    Portier, Bruno
    Bobbia, Michel
    Poggi, Jean-Michel
    [J]. DATA IN BRIEF, 2024, 55
  • [3] Low-cost air quality monitors Modeling and characterization of sensor drift in optical particle counters
    Taylor, Michael D.
    [J]. 2016 IEEE SENSORS, 2016,
  • [4] Laboratory Evaluation and Calibration of Low-Cost Sensors for Air Quality Measurement
    Ionascu, Marian-Emanuel
    Gruicin, Iasmina
    Marcu, Marius
    [J]. 2018 IEEE 12TH INTERNATIONAL SYMPOSIUM ON APPLIED COMPUTATIONAL INTELLIGENCE AND INFORMATICS (SACI), 2018, : 395 - 400
  • [5] THE USE OF LOW-COST SENSORS IN INDUSTRIAL HVAC AND AIR QUALITY MEASUREMENT APPLICATIONS
    Diaconu, Emil
    [J]. SCIENTIFIC PAPERS-SERIES E-LAND RECLAMATION EARTH OBSERVATION & SURVEYING ENVIRONMENTAL ENGINEERING, 2022, 11 : 525 - 530
  • [6] Solution to the Problem of Calibration of Low-Cost Air Quality Measurement Sensors in Networks
    Miskell, Georgia
    Salmond, Jennifer A.
    Williams, David E.
    [J]. ACS SENSORS, 2018, 3 (04): : 832 - 843
  • [7] Machine learning techniques to improve the field performance of low-cost air quality sensors
    Bush, Tony
    Papaioannou, Nick
    Leach, Felix
    Pope, Francis D.
    Singh, Ajit
    Thomas, G. Neil
    Stacey, Brian
    Bartington, Suzanne
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2022, 15 (10) : 3261 - 3278
  • [8] Ambient Air Quality Measurement with Low-Cost Optical and Electrochemical Sensors: An Evaluation of Continuous Year-Long Operation
    Bilek, Jiri
    Bilek, Ondrej
    Marsolek, Petr
    Bucek, Pavel
    [J]. ENVIRONMENTS, 2021, 8 (11)
  • [9] Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation
    Peck, Angela
    Handy, Rodney G.
    Sleeth, Darrah K.
    Schaefer, Camie
    Zhang, Yue
    Pahler, Leon F.
    Ramsay, Joemy
    Collingwood, Scott C.
    [J]. TOXICS, 2023, 11 (01)
  • [10] Low-Cost Air Quality Measurement System Based on Electrochemical and PM Sensors with Cloud Connection
    Arroyo, Patricia
    Gomez-Suarez, Jaime
    Ignacio Suarez, Jose
    Lozano, Jesus
    [J]. SENSORS, 2021, 21 (18)