Inter-rater reliability and agreement of 6 Minute Walk Test and 10 Meter Walk Test at comfortable walk speed in patients with acute stroke

被引:11
|
作者
Busk, Henriette [1 ,2 ,3 ]
Holm, Paetur [1 ,4 ]
Skou, Soren [1 ,4 ]
Seitner, Simon [2 ]
Siemsen, Troels [2 ]
Wienecke, Troels [2 ,5 ]
机构
[1] Naestved Slagelse Ringsted Hosp, Dept Physiotherapy & Occupat Therapy, Res Unit PROgrez, DK-4200 Slagelse, Denmark
[2] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[3] Univ Copenhagen, Dept Neurosci, Copenhagen, Denmark
[4] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Res Unit Musculoskeletal Funct & Physiotherapy, Odense, Denmark
[5] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
Six Minute Walk Test; Ten Meter Walk Test; reliability; agreement; acute stroke; TEST-RETEST RELIABILITY; 6-MINUTE WALK; PROPORTIONAL RECOVERY; REHABILITATION; POSTSTROKE; VALIDITY; EXERCISE; TIME; RECOMMENDATIONS; INDIVIDUALS;
D O I
10.1080/09593985.2022.2030830
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: Remediation of gait problems is a key feature of neurological physiotherapy We aimed to investigate the inter-rater reliability and agreement of the Six Minute Walk Test (6MWT) and Ten Meter Walk Test (10MWT), at comfortable walking speed, in hospitalized acute ischemic stroke patients. Method: Forty acute first-time patients with brain stem or hemispheric ischemic stroke aged 67.4 +/- 12.5 (SD), able to walk with or without an assistive device, were tested by one of three physiotherapists. Test-retest reliability was evaluated using a one-way random effects single measures model (1,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Agreement was evaluated using the Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC). Results: Both tests demonstrated good reliability; ICC1,1 0.83 (CI 95% 0.70-0.90) (6MWT) and 0.76 (CI 95% 0.59-0.87) (10MWT). The 6MWT-SEM was 27.2 m (m) and the SDC was 75.4 m. The 10MWT-SEM was 0.36 meters per second (m/s) and the SDC was 1.0 m/s. Conclusion: Both tests demonstrated good inter-rater reliability, confirming their discriminative ability on a group of hospitalized first-time acute ischemic stroke patients. However, the measurement error was large for both tests, which is likely due to spontaneous neurological recovery and stress in the acute phase severely affecting the individual-level agreement estimate.
引用
收藏
页码:1024 / 1032
页数:9
相关论文
共 50 条
  • [31] DOES 1-MINUTE WALK TEST PREDICT RESULTS OF 6-MINUTE WALK TEST IN PATIENTS WITH IDIOPATHIC PULMONARY FIBROSIS?
    Nunes, Flavia S.
    Pastre, Jean
    Brown, Anne W.
    Shlobin, Oksana A.
    King, Christopher
    Weir, Nargues A.
    Nathan, Steven D.
    SARCOIDOSIS VASCULITIS AND DIFFUSE LUNG DISEASES, 2021, 38 (01)
  • [32] Does 1-Minute Walk Test Predict Results of 6-Minute Walk Test in Patients With Idiopathic Pulmonary Fibrosis?
    Nunes, Flavia
    Alhalabi, Lubna
    Brown, Whitney
    King, Christopher
    Shlobin, Oksana
    Nathan, Steven
    CHEST, 2017, 152 (04) : 486A - 486A
  • [33] Does 1-minute walk test predict results of 6-minute walk test in patients with interstitial lung diseases?
    Soliman, Engy M.
    Madkour, Ashraf M.
    Dwedar, Ibrahim A.
    Abdelkader, Maryam A.
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2023, 72 (02): : 247 - 252
  • [34] The Cone Evasion Walk test: Reliability and validity in acute stroke
    Sjoholm, Hanna
    Hagg, Staffan
    Nyberg, Lars
    Rolander, Bo
    Kammerlind, Ann-Safi
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2019, 24 (01)
  • [35] Predictors of 6-minute walk test and 12-minute walk/run test in obese children and adolescents
    Patrick Calders
    Benedicte Deforche
    Sabine Verschelde
    Jacques Bouckaert
    Frederic Chevalier
    Eddy Bassle
    Ann Tanghe
    Patrick De Bode
    Hilde Franckx
    European Journal of Pediatrics, 2008, 167 : 563 - 568
  • [36] Predictors of 6-minute walk test and 12-minute walk/run test in obese children and adolescents
    Calders, Patrick
    Deforche, Benedicte
    Verschelde, Sabine
    Bouckaert, Jacques
    Chevalier, Frederic
    Bassle, Eddy
    Tanghe, Ann
    De Bode, Patrick
    Franckx, Hilde
    EUROPEAN JOURNAL OF PEDIATRICS, 2008, 167 (05) : 563 - 568
  • [37] Is the 2-Minute Walk Test an Effective Alternative to the 6-Minute Walk Test in Class III Obesity?
    Feola, Sarah
    Ghaderian, Niloufar
    Morais, Jose
    Bacon, Simon
    Andalib, Amin
    Demyttenaere, Sebastian
    Court, Olivier
    Demmers, Thea
    Santosa, Sylvia
    OBESITY, 2021, 29 : 121 - 121
  • [38] Intra- and inter-rater reproducibility of the 6-minute walk test and the 30-second sit-to-stand test in patients with severe and very severe COPD
    Hansen, Henrik
    Beyer, Nina
    Frolich, Anne
    Godtfredsen, Nina
    Bieler, Theresa
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 3447 - 3457
  • [39] Assessing Walking Ability in People with HTLV-1-Associated Myelopathy Using the 10 Meter Timed Walk and the 6 Minute Walk Test
    Adonis, Adine
    Taylor, Graham P.
    PLOS ONE, 2016, 11 (06):
  • [40] Reproducibility and relationships of the 6-minute walk test and shuttle walk test in children with cerebral palsy
    Silva, Natalia
    Cahalin, Lawrence
    Dal Corso, Simone
    Ross, Arena
    Oliveira, Claudia
    Sampaio, Luciana Malosa
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48