Inter-rater reliability and agreement of 6 Minute Walk Test and 10 Meter Walk Test at comfortable walk speed in patients with acute stroke

被引:11
|
作者
Busk, Henriette [1 ,2 ,3 ]
Holm, Paetur [1 ,4 ]
Skou, Soren [1 ,4 ]
Seitner, Simon [2 ]
Siemsen, Troels [2 ]
Wienecke, Troels [2 ,5 ]
机构
[1] Naestved Slagelse Ringsted Hosp, Dept Physiotherapy & Occupat Therapy, Res Unit PROgrez, DK-4200 Slagelse, Denmark
[2] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[3] Univ Copenhagen, Dept Neurosci, Copenhagen, Denmark
[4] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Res Unit Musculoskeletal Funct & Physiotherapy, Odense, Denmark
[5] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
Six Minute Walk Test; Ten Meter Walk Test; reliability; agreement; acute stroke; TEST-RETEST RELIABILITY; 6-MINUTE WALK; PROPORTIONAL RECOVERY; REHABILITATION; POSTSTROKE; VALIDITY; EXERCISE; TIME; RECOMMENDATIONS; INDIVIDUALS;
D O I
10.1080/09593985.2022.2030830
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: Remediation of gait problems is a key feature of neurological physiotherapy We aimed to investigate the inter-rater reliability and agreement of the Six Minute Walk Test (6MWT) and Ten Meter Walk Test (10MWT), at comfortable walking speed, in hospitalized acute ischemic stroke patients. Method: Forty acute first-time patients with brain stem or hemispheric ischemic stroke aged 67.4 +/- 12.5 (SD), able to walk with or without an assistive device, were tested by one of three physiotherapists. Test-retest reliability was evaluated using a one-way random effects single measures model (1,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Agreement was evaluated using the Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC). Results: Both tests demonstrated good reliability; ICC1,1 0.83 (CI 95% 0.70-0.90) (6MWT) and 0.76 (CI 95% 0.59-0.87) (10MWT). The 6MWT-SEM was 27.2 m (m) and the SDC was 75.4 m. The 10MWT-SEM was 0.36 meters per second (m/s) and the SDC was 1.0 m/s. Conclusion: Both tests demonstrated good inter-rater reliability, confirming their discriminative ability on a group of hospitalized first-time acute ischemic stroke patients. However, the measurement error was large for both tests, which is likely due to spontaneous neurological recovery and stress in the acute phase severely affecting the individual-level agreement estimate.
引用
收藏
页码:1024 / 1032
页数:9
相关论文
共 50 条
  • [11] Two-minute versus 6-minute walk distances during 6-minute walk test in neuromuscular disease: Is the 2-minute walk test an effective alternative to a 6-minute walk test?
    Witherspoon, J. W.
    Vasavada, R.
    Logaraj, R. H.
    Waite, M.
    Collins, J.
    Shieh, C.
    Meilleur, K.
    Bonnemann, C.
    Jain, M.
    EUROPEAN JOURNAL OF PAEDIATRIC NEUROLOGY, 2019, 23 (01) : 165 - 170
  • [12] Measuring walking speed in COPD: test-retest reliability of the 30-metre walk test and comparison with the 6-minute walk test
    Andersson, Mikael
    Moberg, Linda
    Svantesson, Ulla
    Sundbom, Ann
    Johansson, Henrik
    Emtner, Margareta
    PRIMARY CARE RESPIRATORY JOURNAL, 2011, 20 (04): : 434 - 440
  • [13] Concurrent validity of the 10-meter walk test as compared with the 6-minute walk test in patients with spinal cord injury at various levels of ability
    Amatachaya, S.
    Naewla, S.
    Srisim, K.
    Arrayawichanon, P.
    Siritaratiwat, W.
    SPINAL CORD, 2014, 52 (04) : 333 - 336
  • [14] Concurrent validity of the 10-meter walk test as compared with the 6-minute walk test in patients with spinal cord injury at various levels of ability
    S Amatachaya
    S Naewla
    K Srisim
    P Arrayawichanon
    W Siritaratiwat
    Spinal Cord, 2014, 52 : 333 - 336
  • [15] Reliability and Validity of the 6-Minute Walk Test in Hypophosphatasia
    Phillips, Dawn
    Tomazos, Ioannis C.
    Moseley, Scott
    L'Italien, Gil
    Gomes da Silva, Hugo
    Lerma Lara, Sergio
    JBMR PLUS, 2019, 3 (06)
  • [16] Assessing the Reliability and Validity of a Shorter Walk Test Compared With the 10-Meter Walk Test for Measurements of Gait Speed in Healthy, Older Adults
    Peters, Denise M.
    Fritz, Stacy L.
    Krotish, Debra E.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2013, 36 (01) : 24 - 30
  • [17] Increase in walk distance is not enough evidence to add a walk to the 6-minute walk test
    Hernandes, N. A.
    Wouters, E. F. M.
    Meijer, K.
    Annegarn, J.
    Pitta, F.
    Spruit, M. A.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 38 (05) : 1240 - +
  • [18] Reliability of the 6-minute walk test in patients referred for pulmonary rehabilitation
    van der Schoot, H. J. M.
    van Ranst, D.
    Otten, H. J.
    Stoop, W. A.
    van de Port, I. G.
    Meijer, J. W.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [19] Is a patient self-recorded 6 minute walk test equivalent to a formally recorded 6 minute walk test
    van Bavel, Dirk
    de Steiger, Richard
    McKenzie, Dean
    ANZ JOURNAL OF SURGERY, 2024, 94 (09) : 1511 - 1517
  • [20] Feasibility, criterion and construct convergent validity of the 2-minute walk test and the 10-meter walk test in an oncological context
    Reinmann, Aline
    Koessler, Thibaud
    Bodmer, Alexandre
    Baud-Grasset, Axelle
    Mentha, Geraldine
    Gligorov, Joseph
    Bruyneel, Anne-Violette
    HELIYON, 2023, 9 (11)