Inter-rater reliability and agreement of 6 Minute Walk Test and 10 Meter Walk Test at comfortable walk speed in patients with acute stroke

被引:11
|
作者
Busk, Henriette [1 ,2 ,3 ]
Holm, Paetur [1 ,4 ]
Skou, Soren [1 ,4 ]
Seitner, Simon [2 ]
Siemsen, Troels [2 ]
Wienecke, Troels [2 ,5 ]
机构
[1] Naestved Slagelse Ringsted Hosp, Dept Physiotherapy & Occupat Therapy, Res Unit PROgrez, DK-4200 Slagelse, Denmark
[2] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[3] Univ Copenhagen, Dept Neurosci, Copenhagen, Denmark
[4] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Res Unit Musculoskeletal Funct & Physiotherapy, Odense, Denmark
[5] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
Six Minute Walk Test; Ten Meter Walk Test; reliability; agreement; acute stroke; TEST-RETEST RELIABILITY; 6-MINUTE WALK; PROPORTIONAL RECOVERY; REHABILITATION; POSTSTROKE; VALIDITY; EXERCISE; TIME; RECOMMENDATIONS; INDIVIDUALS;
D O I
10.1080/09593985.2022.2030830
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: Remediation of gait problems is a key feature of neurological physiotherapy We aimed to investigate the inter-rater reliability and agreement of the Six Minute Walk Test (6MWT) and Ten Meter Walk Test (10MWT), at comfortable walking speed, in hospitalized acute ischemic stroke patients. Method: Forty acute first-time patients with brain stem or hemispheric ischemic stroke aged 67.4 +/- 12.5 (SD), able to walk with or without an assistive device, were tested by one of three physiotherapists. Test-retest reliability was evaluated using a one-way random effects single measures model (1,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Agreement was evaluated using the Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC). Results: Both tests demonstrated good reliability; ICC1,1 0.83 (CI 95% 0.70-0.90) (6MWT) and 0.76 (CI 95% 0.59-0.87) (10MWT). The 6MWT-SEM was 27.2 m (m) and the SDC was 75.4 m. The 10MWT-SEM was 0.36 meters per second (m/s) and the SDC was 1.0 m/s. Conclusion: Both tests demonstrated good inter-rater reliability, confirming their discriminative ability on a group of hospitalized first-time acute ischemic stroke patients. However, the measurement error was large for both tests, which is likely due to spontaneous neurological recovery and stress in the acute phase severely affecting the individual-level agreement estimate.
引用
收藏
页码:1024 / 1032
页数:9
相关论文
共 50 条
  • [1] Agreement in Walking Speed Measured Using Four Different Outcome Measures: 6-Meter Walk Test, 10-Meter Walk Test, 2-Minute Walk Test, and 6-Minute Walk Test
    Rousch, James
    Heick, John D.
    HawK, Tanner
    Eurek, Dillon
    Kiflu, Daniel
    Wallis, Austin
    INTERNET JOURNAL OF ALLIED HEALTH SCIENCES AND PRACTICE, 2021, 19 (02):
  • [2] Reliability, validity and minimal detectable change of 2-minute walk test, 6-minute walk test and 10-meter walk test in frail older adults with dementia
    Chan, Wayne L. S.
    Pin, Tamis W.
    EXPERIMENTAL GERONTOLOGY, 2019, 115 : 9 - 18
  • [3] Gait speed in knee osteoarthritis: A simple 10-meter walk test predicts the distance covered in the 6-minute walk test
    Lozano-Meca, Jose
    Montilla-Herrador, Joaquina
    Gacto-Sanchez, Mariano
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 72
  • [4] Six minute walk test inter-rater reproducibility in COPD patients: Cross-sectional study
    Arcuri, Juliano Ferreira
    Labadessa, Ivana Goncalves
    Ferreira da Costa, Joyce Nogueira
    Pessoa, Bruna Varanda
    Jamami, Mauricio
    Pires Di Lorenzo, Valeria Amorim
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [5] FEASIBILITY AND RELIABILITY OF THE 2 MINUTE WALK TEST AND 6 MINUTE WALK TEST IN CHILDREN WITH CONGENITAL MYOTONIC DYSTROPHY
    DiBella, D.
    Hayes, H.
    Hung, M.
    Chen, W.
    Crockett, B.
    Pusillo, E.
    Dixon, M.
    Butterfield, R.
    Bounsanga, J.
    Johnson, N.
    Campbell, C.
    MUSCLE & NERVE, 2015, 52 : S4 - S4
  • [6] Practice effect and cueing of 2-minute walk test, 6-minute walk test and 10-meter walk test in frail older adults with and without dementia - Recommendations to walk tests protocols
    Chan, Wayne L. S.
    Pin, Tamis W.
    EXPERIMENTAL GERONTOLOGY, 2019, 124
  • [7] Safety and Feasibility of the 6-Minute Walk Test in Patients with Acute Stroke
    Kubo, Hiroki
    Nozoe, Masafumi
    Yamamoto, Miho
    Kamo, Arisa
    Noguchi, Madoka
    Kanai, Masashi
    Mase, Kyoshi
    Shimada, Shinichi
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2018, 27 (06): : 1632 - 1638
  • [8] Reliability, agreement, and responsiveness of a 6-minute walk/run test in patients with heart disease
    Berghmans, Danielle D.
    Lenssen, Antoine F.
    Bastiaenen, Carolien H.
    Ilhan, Mustafa
    Lencer, Nicole H.
    Roox, George M.
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2013, 20 (01) : 135 - 141
  • [9] Comparison Of The Incremental Shuttle Walk Test With 6 Minute Walk Test In Patients With Breast Cancer
    Yagli, Naciye Vardar
    Sener, Gul
    Saglam, Melda
    Arikan, Hulya
    Inal-Ince, Deniz
    Savci, Sema
    Calik-Kutukcu, Ebru
    Altundag, Kadri
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 759 - 759
  • [10] Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways
    Cheng, Darren K.
    Nelson, Michelle
    Brooks, Dina
    Salbach, Nancy M.
    TOPICS IN STROKE REHABILITATION, 2020, 27 (04) : 251 - 261